1SDA100488R1 ABB XT5H 400 Ekip Dip LS/I 250A 3-Pole Moulded Case Circuit Breaker

1SDA100488R1 ABB XT5H 400 Ekip Dip LS/I 250A 3-Pole Moulded Case Circuit Breaker

ABB 1SDA100488R1 XT5H 400 Ekip Dip LS/I is a 250 A three-pole fixed moulded-case circuit breaker with front terminals, solid-state electronic overload and short-circuit protection and a 70 kA ultimate breaking capacity at 380 V AC.

SKU: 1SDA100488R1MPN: 1SDA100488R1
Price
List Price £1,351.85 ex VAT
Your Price (ex VAT) Save 25%
£1,013.89 25% OFF
You save £337.96 per unit
Manufacturer Lead Time Estimated Delivery 5 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £1,013.89
Trade pricing is personalised to your account

Manufacturer Lead Time

£1,013.89

Why Choose the ABB XT5H 400 Ekip Dip LS/I 1SDA100488R1 Circuit Breaker?

The ABB 1SDA100488R1 is a high-performance SACE Tmax XT5H moulded-case circuit breaker (MCCB) designed for dependable protection and switching in demanding low-voltage AC distribution systems. This fixed three-pole circuit breaker features front terminals and an Ekip Dip LS/I solid-state electronic trip unit, providing configurable overload and short-circuit protection.

As part of the ABB SACE Tmax XT series, the XT5H 400 combines compact construction with a high breaking-capacity class and electronic protection. The Ekip Dip LS/I release provides Long-time (L) overload protection together with selectable Short-time (S) or Instantaneous (I) short-circuit protection, supporting effective coordination with cables, feeders and downstream protective devices.

The 1SDA100488R1 has a 250 A rated current on the XT5 400 frame and a three-pole configuration. The XT5H platform provides an ultimate short-circuit breaking capacity of 70 kA at 380 V AC, making this breaker particularly suitable for industrial and commercial distribution systems with demanding prospective fault-current requirements.

Key Advantages

  • High-performance ABB SACE Tmax XT5H moulded-case circuit breaker.
  • 250 A rated current on the XT5 400 frame.
  • Ekip Dip LS/I solid-state electronic trip unit for configurable circuit protection.
  • Long-time overload protection with selectable short-time or instantaneous short-circuit protection.
  • High H-class breaking capacity for installations with elevated prospective fault currents.
  • 70 kA ultimate short-circuit breaking capacity at 380 V AC.
  • Fixed three-pole construction with front terminals for straightforward switchboard integration.

Key Features

  • ABB SACE Tmax XT5H 400 moulded-case circuit breaker.
  • 250 A rated current (In).
  • Ekip Dip LS/I solid-state electronic release.
  • Long-time (L) overload protection.
  • Short-time (S) / Instantaneous (I) short-circuit protection functionality.
  • Long-time current adjustment from 0.4–1 × In.
  • Three-pole circuit-breaker configuration.
  • Fixed mounting design.
  • Front terminals for main-circuit connections.
  • H interruption rating within the SACE Tmax XT5 range.
  • Solid-state protection designed for AC distribution systems.
  • Suitable for high-fault-level industrial and commercial distribution applications.

Advanced Electronic Protection for High-Fault-Level Distribution

The ABB Ekip Dip LS/I release provides electronic protection for applications requiring dependable overload and short-circuit response. Long-time protection monitors sustained overcurrent conditions and offers a current adjustment range from 0.4–1 × In, allowing the breaker to be coordinated with the protected conductor and load requirements.

The LS/I configuration combines Long-time protection with selectable Short-time or Instantaneous short-circuit protection. Together with the XT5H breaker's high interruption capability, including an Icu of 70 kA at 380 V AC, this makes the 1SDA100488R1 particularly suitable for distribution points where both electronic protection flexibility and high fault-clearing capability are required.

Typical Applications

  • Industrial low-voltage power distribution systems.
  • Main and sub-distribution switchboards.
  • High-fault-level feeder and cable protection.
  • Transformer-fed distribution systems.
  • Manufacturing and process installations.
  • Commercial building electrical distribution.
  • Infrastructure and critical power distribution systems.

Technical Specifications

Series SACE Tmax XT
Frame size XT5
Order code 1SDA100488R1
Alternate catalogue number XT5HE325AEFF000XXX
Product type Moulded-case circuit breaker (MCCB)
Rated current (In) 250 A
Frame size rating 400 A
Number of poles 3
Trip unit Ekip Dip LS/I
Release type Solid-state electronic
Protection functions Long-time (L) and Short-time / Instantaneous (S/I)
Long-time current adjustment 0.4–1 × In
Ultimate short-circuit breaking capacity (Icu) at 230 V AC 100 kA
Ultimate short-circuit breaking capacity (Icu) at 380 V AC 70 kA
Ultimate short-circuit breaking capacity (Icu) at 440 V AC 65 kA
Interruption rating H
Current type AC
Mounting type Fixed
Terminal position Front
Standard IEC 60947-2
Approximate net weight 5.308 kg
GTIN / UPC 8056221005654

Frequently Asked Questions

What is the ABB 1SDA100488R1 used for?

The ABB 1SDA100488R1 is a 250 A three-pole moulded-case circuit breaker designed for overload and short-circuit protection in low-voltage AC distribution systems, particularly where a high short-circuit breaking capacity is required.

What is the rated current of the ABB XT5H 400 Ekip Dip LS/I?

The 1SDA100488R1 has a rated current of 250 A and uses the ABB SACE Tmax XT5 400 frame.

What does Ekip Dip LS/I mean?

The Ekip Dip LS/I electronic release provides Long-time (L) overload protection together with selectable Short-time (S) or Instantaneous (I) short-circuit protection, allowing the breaker to be configured for the protection and coordination requirements of the installation.

How many poles does the ABB 1SDA100488R1 have?

The 1SDA100488R1 is a three-pole circuit breaker supplied in a fixed configuration with front terminals.

What is the breaking capacity of the ABB XT5H 400?

The XT5H platform provides an ultimate short-circuit breaking capacity (Icu) of 100 kA at 230 V AC, 70 kA at 380 V AC and 65 kA at 440 V AC.

Trusted ABB Circuit Protection Technology

ABB SACE Tmax XT moulded-case circuit breakers combine dependable switching, configurable electronic protection and high short-circuit breaking performance for demanding industrial, commercial and infrastructure low-voltage distribution applications.