1SDA100477R1 ABB XT5S 400 TMG 400-2000 400A 4-Pole Circuit Breaker

1SDA100477R1 ABB XT5S 400 TMG 400-2000 400A 4-Pole Circuit Breaker

ABB 1SDA100477R1 XT5S 400 is a 400 A four-pole fixed moulded case circuit breaker with a TMG 400-2000 thermomagnetic trip unit and fully rated neutral for generator, transformer and electrical distribution protection.

SKU: 1SDA100477R1MPN: 1SDA100477R1
Price
List Price £1,501.84 ex VAT
Your Price (ex VAT) Save 25%
£1,126.38 25% OFF
You save £375.46 per unit
Manufacturer Lead Time Estimated Delivery 5 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £1,126.38
Trade pricing is personalised to your account

Manufacturer Lead Time

£1,126.38

Why Choose the ABB 1SDA100477R1 XT5S 400 Circuit Breaker?

The ABB 1SDA100477R1 is a high-performance four-pole moulded case circuit breaker (MCCB) designed for generator, transformer and low-voltage installation protection. Part of the ABB SACE Tmax XT series, this XT5S 400 breaker combines a compact fixed design with a TMG thermomagnetic trip unit for dependable overload and short-circuit protection.

The circuit breaker has a 400 A rated current and uses the XT5 400 A frame. Its TMG 400-2000 thermomagnetic release provides adjustable thermal overload protection together with instantaneous magnetic short-circuit protection adjustable up to 2000 A, supporting reliable protection of generators and associated low-voltage distribution circuits.

The XT5S performance level provides increased short-circuit interruption capability for demanding electrical installations. Its four-pole configuration incorporates a fully rated neutral at 100% of In, while the fixed construction and front terminal connections support straightforward integration into generator switchboards, industrial distribution panels and three-phase four-wire systems.

Key Advantages

  • High-performance ABB Tmax XT moulded case circuit breaker for generator and distribution protection.
  • 400 A rated current within the XT5 400 A frame.
  • TMG thermomagnetic trip unit for combined overload and short-circuit protection.
  • Instantaneous magnetic protection adjustable up to 2000 A.
  • Four-pole configuration with neutral rated at 100% of In.
  • Fixed mounting with front terminals for straightforward switchboard integration.

Key Features

  • ABB SACE Tmax XT series.
  • XT5S 400 frame configuration.
  • 400 A rated current.
  • TMG 400-2000 thermomagnetic trip unit.
  • Adjustable thermal overload protection.
  • Instantaneous magnetic short-circuit protection adjustable up to 2000 A.
  • Four-pole configuration for three-phase four-wire systems.
  • Neutral protection rated at 100% of In.
  • S short-circuit performance level.
  • Fixed mounting with front main-circuit connections.

Reliable Generator and Distribution Protection

Moulded case circuit breakers such as the ABB XT5S protect electrical installations against damaging overload and short-circuit conditions. The TMG thermomagnetic release combines thermal overload protection with instantaneous magnetic short-circuit protection, providing dependable protection characteristics for generators, transformers and associated low-voltage distribution circuits.

The four-pole design incorporates a fully rated neutral at 100% of In, making the 1SDA100477R1 particularly suitable for three-phase four-wire systems requiring full neutral current capability. Together with its S-class performance, compact fixed construction and front-connected arrangement, the breaker provides a robust solution for industrial switchboards and distribution assemblies.

Typical Applications

  • Generator protection and generator switchboards.
  • Transformer and installation protection.
  • Three-phase four-wire electrical systems.
  • Industrial power distribution systems.
  • Main and sub-distribution switchboards.
  • Manufacturing, commercial and infrastructure electrical installations.

Technical Specifications

Series SACE Tmax XT
Order code 1SDA100477R1
Product type Moulded case circuit breaker
Application Generator, transformer and electrical distribution protection
Frame size XT5
Frame rating 400 A
Rated current (In) 400 A
Number of poles 4
Neutral rating 100% of In
Trip unit TMG 400-2000
Release type Thermomagnetic
Instantaneous short-circuit release up to 2000 A
Short-circuit performance level S
Mounting version Fixed
Terminal connection Front
Standard IEC 60947-2

Frequently Asked Questions

What is the ABB 1SDA100477R1 used for?

The ABB 1SDA100477R1 is a four-pole moulded case circuit breaker designed for generator, transformer and low-voltage electrical distribution protection.

What is the rated current of the ABB 1SDA100477R1?

The circuit breaker has a rated current of 400 A and uses the ABB XT5 400 A frame.

What protection does the TMG 400-2000 trip unit provide?

The TMG thermomagnetic trip unit provides thermal overload protection together with instantaneous magnetic short-circuit protection adjustable up to 2000 A.

What does In=100%In mean on the ABB 1SDA100477R1?

It means the neutral is rated at 100% of the breaker rated current, providing full neutral current capability for suitable three-phase four-wire electrical systems.

How is the ABB 1SDA100477R1 installed?

The 1SDA100477R1 is a fixed four-pole circuit breaker with front terminals, making it suitable for integration into generator switchboards, industrial distribution panels and other low-voltage electrical assemblies.

Trusted by Electrical Engineers Worldwide

ABB SACE Tmax XT moulded case circuit breakers are widely used in generator, transformer and industrial power distribution systems where dependable overload and short-circuit protection, compact installation and robust switching performance are essential.