1SDA100467R1 ABB XT5S 630 Ekip Dip LS/I 630 A 4-Pole Circuit Breaker

1SDA100467R1 ABB XT5S 630 Ekip Dip LS/I 630 A 4-Pole Circuit Breaker

ABB 1SDA100467R1 XT5S 630 Ekip Dip LS/I is a 630 A four-pole fixed moulded case circuit breaker with front terminals, adjustable electronic overload and short-circuit protection, and 50 kA breaking capacity at 415 V AC for demanding low-voltage electrical distribution systems.

SKU: 1SDA100467R1MPN: 1SDA100467R1
Price
List Price £2,920.94 ex VAT
Your Price (ex VAT) Save 25%
£2,190.71 25% OFF
You save £730.24 per unit
Manufacturer Lead Time Estimated Delivery 4 - 5 Days
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £2,190.71
Trade pricing is personalised to your account

Manufacturer Lead Time

£2,190.71

Why Choose the ABB XT5S 630 Ekip Dip LS/I 1SDA100467R1 Circuit Breaker?

The ABB XT5S 630 Ekip Dip LS/I 1SDA100467R1 is a high-performance 630 A moulded case circuit breaker (MCCB) designed for dependable protection and switching in demanding low-voltage electrical distribution systems. Part of the ABB SACE Tmax XT series, this four-pole breaker combines the XT5 630 frame with an electronic Ekip Dip LS/I trip unit and S-class short-circuit performance.

The XT5S is engineered for transformer, generator and installation protection where accurate electronic overload and short-circuit protection is required. Its Ekip Dip LS/I solid-state release provides adjustable long-time protection together with selectable short-time or instantaneous short-circuit protection, supporting effective selectivity and coordination throughout electrical distribution networks.

With a rated current of 630 A, a four-pole fixed configuration with front terminals and an ultimate short-circuit breaking capacity of 50 kA at 415 V AC, the 1SDA100467R1 is well suited to industrial and commercial switchboards. Its long-time protection is adjustable over 0.4–1 × In, while short-circuit protection is adjustable over 1–10 × In.

Key Advantages

  • High-performance 630 A moulded case circuit breaker for demanding low-voltage distribution.
  • Ekip Dip LS/I electronic trip unit provides adjustable overload and short-circuit protection.
  • Long-time protection adjustable over 0.4–1 × In.
  • Short-circuit protection adjustable over 1–10 × In.
  • 50 kA ultimate breaking capacity at 415 V AC for high-fault-level installations.
  • Four-pole fixed construction with front terminals supports straightforward switchboard integration.

Key Features

  • ABB SACE Tmax XT series.
  • XT5S 630 frame with S breaking-capacity class.
  • 630 A rated current.
  • Ekip Dip LS/I solid-state electronic release.
  • Long-time overload protection adjustable from 252–630 A.
  • Short-circuit protection adjustable from 630–6300 A.
  • Four poles for three-phase and neutral distribution systems.
  • Fixed mounting with front main-circuit terminals.
  • Rated operational voltage up to 690 V AC.
  • Rated insulation voltage of 1000 V and impulse withstand voltage of 8 kV.

Reliable Protection for High-Current Distribution Systems

Moulded case circuit breakers such as the ABB XT5S provide protection against overload and short-circuit conditions while also offering a practical means of switching and isolation. Electronic trip technology enables protection characteristics to be adjusted for the installation, helping engineers coordinate breakers with conductors, transformers, generators and downstream protective devices.

The Ekip Dip LS/I release combines adjustable long-time overload protection with selectable short-time or instantaneous short-circuit protection. Together with the four-pole XT5S construction, 630 A current rating and S-class interruption capability, this makes the 1SDA100467R1 particularly suitable for high-current feeders and demanding three-phase and neutral distribution systems.

Typical Applications

  • Industrial low-voltage distribution boards.
  • Main and high-current feeder protection.
  • Transformer protection and distribution systems.
  • Generator distribution and protection systems.
  • Commercial and infrastructure switchboards.
  • Manufacturing and process facilities.

Technical Specifications

Series SACE Tmax XT
Frame size XT5 630
ABB order code 1SDA100467R1
Alternate catalogue number XT5SE463BEFF000XXX
EAN / UPC 8056221005449
Product type Moulded case circuit breaker (MCCB)
Rated current (In) 630 A
Rated uninterrupted current (Iu) 630 A
Number of poles 4
Trip unit Ekip Dip LS/I
Release type Electronic / solid-state
Long-time setting range 0.4–1 × In
Long-time current range 252–630 A
Short-circuit setting range 1–10 × In
Short-circuit current range 630–6300 A
Breaking-capacity class S
Ultimate breaking capacity (Icu) at 415 V AC 50 kA
Rated operational voltage 690 V AC
Rated insulation voltage (Ui) 1000 V
Rated impulse withstand voltage (Uimp) 8 kV
Rated short-time withstand current (Icw) 6 kA
Mounting type Fixed
Terminal arrangement Front terminals
Current type AC
Electrical durability 5000 cycles
Standard IEC 60947-2

Frequently Asked Questions

What is the ABB 1SDA100467R1 used for?

The ABB 1SDA100467R1 is a 630 A four-pole moulded case circuit breaker designed for transformer, generator, installation and feeder protection in demanding low-voltage electrical distribution systems.

What trip unit is fitted to the XT5S 630 1SDA100467R1?

This circuit breaker is fitted with an Ekip Dip LS/I electronic trip unit, providing adjustable long-time overload protection together with selectable short-time or instantaneous short-circuit protection.

What protection adjustment ranges does the 1SDA100467R1 provide?

The long-time protection is adjustable over 0.4–1 × In, corresponding to 252–630 A, while the short-circuit protection is adjustable over 1–10 × In, corresponding to 630–6300 A.

What is the breaking capacity of the XT5S 1SDA100467R1?

The XT5S S-class circuit breaker provides an ultimate short-circuit breaking capacity of 50 kA at 415 V AC, making it suitable for demanding low-voltage distribution installations.

How is the ABB XT5S 1SDA100467R1 installed?

This version is a four-pole fixed-mounted circuit breaker with front terminals, designed for integration into industrial and commercial low-voltage switchboards.

Trusted by Electrical Professionals Worldwide

ABB SACE Tmax XT moulded case circuit breakers are widely used by panel builders, electrical engineers and industrial operators for dependable low-voltage circuit protection, flexible protection coordination and high-performance fault interruption.