1SDA100415R1 ABB XT5S 400 TMA 400-4000 3-Pole Fixed Circuit Breaker

1SDA100415R1 ABB XT5S 400 TMA 400-4000 3-Pole Fixed Circuit Breaker

ABB 1SDA100415R1 is a 400 A three-pole fixed SACE Tmax XT5S moulded case circuit breaker with front terminals, a TMA thermomagnetic release and 50 kA ultimate short-circuit breaking capacity at 415 V AC.

SKU: 1SDA100415R1MPN: 1SDA100415R1
Price
List Price £1,315.31 ex VAT
Your Price (ex VAT) Save 25%
£986.48 25% OFF
You save £328.83 per unit
Manufacturer Lead Time Estimated Delivery 4 - 5 Days
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £986.48
Trade pricing is personalised to your account

Manufacturer Lead Time

£986.48

Why Choose the ABB XT5S 400 TMA 400-4000 3P Circuit Breaker?

The ABB XT5S 400 TMA 400-4000 3P F F 1SDA100415R1 is a fixed three-pole SACE Tmax XT5 moulded case circuit breaker designed for reliable protection of low-voltage electrical distribution systems. Rated at 400 A, it combines the XT5S breaking part with a TMA thermomagnetic release for overload and short-circuit protection.

The TMA thermomagnetic trip unit provides thermal overload protection together with adjustable instantaneous magnetic short-circuit protection. Its instantaneous magnetic threshold is adjustable from 2000–4000 A, enabling the breaker to be coordinated with the characteristics and fault-protection requirements of the connected circuit.

The 1SDA100415R1 is supplied as a fixed three-pole breaker with front terminals. The XT5S performance class provides an ultimate short-circuit breaking capacity of 50 kA at 415 V AC, making it suitable for demanding industrial, commercial and infrastructure installations requiring robust fault interruption.

Key Advantages

  • Complete ABB SACE Tmax XT5S moulded case circuit breaker.
  • 400 A rated current for substantial low-voltage distribution loads.
  • TMA thermomagnetic release for overload and short-circuit protection.
  • Adjustable instantaneous magnetic protection from 2000–4000 A.
  • 50 kA ultimate breaking capacity at 415 V AC.
  • Three-pole configuration for three-phase electrical systems.
  • Fixed mounting for permanent switchboard installations.
  • Front terminals for conventional power-circuit connection.

Key Features

  • ABB SACE Tmax XT series.
  • XT5S 400 frame.
  • 400 A rated current.
  • Three poles.
  • TMA thermomagnetic trip unit.
  • Thermal overload protection.
  • Adjustable instantaneous magnetic short-circuit protection.
  • S interruption-performance class.
  • Fixed execution.
  • Front terminal connections.

Thermomagnetic Protection with High Breaking Performance

The ABB XT5S 400 uses a TMA thermomagnetic release to provide dependable protection without requiring an electronic trip unit. The thermal element responds to sustained overload conditions, while the magnetic element provides rapid interruption of short-circuit currents with an adjustable instantaneous threshold from 2000–4000 A.

With its 400 A rating, 50 kA ultimate breaking capacity at 415 V AC and fixed front-terminal construction, the 1SDA100415R1 provides a robust protection solution for feeders, transformers, generators and electrical installations where dependable high-fault-current interruption is required.

Typical Applications

  • Industrial low-voltage distribution boards.
  • Main and sub-main switchboards.
  • Commercial building power distribution.
  • Manufacturing and process installations.
  • Three-phase feeder and cable protection.
  • Transformer protection.
  • Generator and installation protection.
  • Circuits requiring high short-circuit interruption capability.

Technical Specifications

Series SACE Tmax XT
Product group T-Max XT 250 Range
ABB order code 1SDA100415R1
Product type Moulded case circuit breaker (MCCB)
Frame size XT5
Frame / rated current 400 A
Interruption rating S
Rated current 400 A
Number of poles 3
Trip unit TMA thermomagnetic release
Instantaneous short-circuit setting (I3) 2000–4000 A
Ultimate short-circuit breaking capacity (Icu) at 415 V AC 50 kA
Mounting Fixed
Terminal arrangement Front terminals
Degree of protection IP20
Standard IEC
Power loss 24.1 W
EAN 8056221004923

Frequently Asked Questions

What is the ABB 1SDA100415R1?

The ABB 1SDA100415R1 is an XT5S 400 fixed three-pole moulded case circuit breaker with front terminals and a 400 A TMA thermomagnetic release.

What is the rated current of the ABB XT5S 1SDA100415R1?

The XT5S circuit breaker and its TMA thermomagnetic release are rated at 400 A.

What protection does the TMA release provide?

The TMA release provides thermal overload protection and instantaneous magnetic short-circuit protection, with the magnetic threshold adjustable from 2000–4000 A.

What is the breaking capacity of the ABB 1SDA100415R1?

The XT5S configuration provides an ultimate short-circuit breaking capacity of 50 kA at 415 V AC.

How is the ABB 1SDA100415R1 mounted and connected?

The 1SDA100415R1 is supplied as a fixed three-pole circuit breaker with front terminals for integration into compatible low-voltage switchboards and distribution assemblies.

Trusted ABB Circuit Protection

ABB SACE Tmax XT moulded case circuit breakers combine compact construction, dependable thermomagnetic protection and high fault-interruption performance for industrial, infrastructure and commercial low-voltage power-distribution systems.