1SDA100414R1 ABB XT5S 400 TMA 320-3200 3-Pole Fixed Circuit Breaker

1SDA100414R1 ABB XT5S 400 TMA 320-3200 3-Pole Fixed Circuit Breaker

ABB 1SDA100414R1 is a 320 A three-pole fixed SACE Tmax XT5S 400 moulded case circuit breaker with front terminals, an adjustable TMA thermomagnetic release and 50 kA ultimate short-circuit breaking capacity at 415 V AC.

SKU: 1SDA100414R1MPN: 1SDA100414R1
Price
List Price £1,315.31 ex VAT
Your Price (ex VAT) Save 25%
£986.48 25% OFF
You save £328.83 per unit
Manufacturer Lead Time Estimated Delivery 5 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £986.48
Trade pricing is personalised to your account

Manufacturer Lead Time

£986.48

Why Choose the ABB XT5S 400 TMA 320-3200 3P Circuit Breaker?

The ABB XT5S 400 TMA 320-3200 3P F F 1SDA100414R1 is a fixed three-pole SACE Tmax XT5 moulded case circuit breaker designed for dependable protection of low-voltage power-distribution systems. It combines an XT5S 400 frame with a 320 A TMA thermomagnetic release for overload and short-circuit protection.

The TMA thermomagnetic trip unit provides adjustable thermal overload protection together with adjustable instantaneous magnetic short-circuit protection. Its thermal setting range is 224–320 A, while the instantaneous magnetic release can be adjusted from 1600–3200 A, supporting effective coordination with cables and connected equipment.

The 1SDA100414R1 is supplied as a fixed three-pole breaker with front terminals. The XT5S performance class provides an ultimate short-circuit breaking capacity of 50 kA at 415 V AC, making this breaker suitable for industrial, commercial and infrastructure installations requiring higher fault-interruption capability.

Key Advantages

  • Complete ABB SACE Tmax XT5S moulded case circuit breaker.
  • 320 A rated current within the XT5 400 frame.
  • TMA thermomagnetic release requiring no electronic trip-unit power supply.
  • Adjustable thermal overload protection from 224–320 A.
  • Adjustable instantaneous short-circuit protection from 1600–3200 A.
  • 50 kA ultimate breaking capacity at 415 V AC.
  • Three-pole configuration for three-phase electrical systems.
  • Fixed mounting with front terminals for straightforward switchboard integration.

Key Features

  • ABB SACE Tmax XT series.
  • XT5S 400 frame.
  • 320 A rated current.
  • Three poles.
  • TMA thermomagnetic trip unit.
  • Adjustable thermal overload protection.
  • Adjustable instantaneous magnetic short-circuit protection.
  • S interruption-performance class.
  • Fixed execution.
  • Front terminal connections.

Adjustable Thermomagnetic Protection with 50 kA Breaking Capacity

The ABB XT5S 400 uses a TMA thermomagnetic release to provide reliable circuit protection without requiring a solid-state electronic trip unit. The thermal element responds to sustained overloads and can be adjusted from 224–320 A, while the magnetic element provides rapid short-circuit protection with an adjustable threshold from 1600–3200 A.

With its 320 A rating, 50 kA ultimate breaking capacity at 415 V AC and fixed front-terminal construction, the 1SDA100414R1 is suited to feeder, transformer, generator and installation protection where robust fault interruption and adjustable thermomagnetic protection are required.

Typical Applications

  • Industrial low-voltage distribution boards.
  • Main and sub-main switchboards.
  • Commercial building power distribution.
  • Manufacturing and process installations.
  • Three-phase feeder and cable protection.
  • Transformer protection.
  • Generator and installation protection.
  • Circuits requiring higher short-circuit interruption capability.

Technical Specifications

Series SACE Tmax XT
Product group T-Max XT 250 Range
ABB order code 1SDA100414R1
Product type Moulded case circuit breaker (MCCB)
Frame size XT5
Frame rating 400 A
Interruption rating S
Rated current (In) 320 A
Number of poles 3
Trip unit TMA thermomagnetic release
Thermal overload setting 224–320 A
Instantaneous short-circuit setting (I3) 1600–3200 A
Ultimate short-circuit breaking capacity (Icu) at 415 V AC 50 kA
Rated operational voltage Up to 690 V AC
Mounting Fixed
Terminal arrangement Front terminals
Standard IEC
Dimensions (W × H × D) 140 × 205 × 103.5 mm
Net weight 4.775 kg
Power loss 16.9 W
EAN 8056221004916

Frequently Asked Questions

What is the ABB 1SDA100414R1?

The ABB 1SDA100414R1 is an XT5S 400 fixed three-pole moulded case circuit breaker with front terminals and a 320 A TMA thermomagnetic release.

What is the rated current of the ABB XT5S 1SDA100414R1?

The circuit breaker uses a TMA thermomagnetic release rated at 320 A within the XT5S 400 frame.

What is the overload adjustment range of the ABB 1SDA100414R1?

The TMA thermal overload release is adjustable from 224–320 A.

What is the short-circuit protection range?

The instantaneous magnetic short-circuit release is adjustable from 1600–3200 A.

What is the breaking capacity of the ABB 1SDA100414R1?

The XT5S configuration provides an ultimate short-circuit breaking capacity of 50 kA at 415 V AC.

Trusted ABB Circuit Protection

ABB SACE Tmax XT moulded case circuit breakers combine compact construction, adjustable thermomagnetic protection and dependable fault-interruption performance for industrial, infrastructure and commercial low-voltage power-distribution systems.