1SDA100407R1 ABB XT5N 400 TMG 400-2000 400A 4-Pole Circuit Breaker

1SDA100407R1 ABB XT5N 400 TMG 400-2000 400A 4-Pole Circuit Breaker

ABB 1SDA100407R1 XT5N 400 is a 400 A four-pole fixed moulded case circuit breaker with a TMG 400-2000 thermomagnetic trip unit and fully rated neutral for generator and electrical distribution protection.

SKU: 1SDA100407R1MPN: 1SDA100407R1
Price
List Price £1,365.21 ex VAT
Your Price (ex VAT) Save 25%
£1,023.91 25% OFF
You save £341.30 per unit
Manufacturer Lead Time Estimated Delivery 5 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £1,023.91
Trade pricing is personalised to your account

Manufacturer Lead Time

£1,023.91

Why Choose the ABB 1SDA100407R1 XT5N 400 Circuit Breaker?

The ABB 1SDA100407R1 is a high-performance four-pole moulded case circuit breaker (MCCB) designed for generator protection and low-voltage electrical distribution applications. Part of the advanced ABB SACE Tmax XT series, this XT5N 400 breaker combines a compact fixed design with a TMG thermomagnetic trip unit for dependable overload and short-circuit protection.

This circuit breaker provides a 400 A rated current and 400 A rated uninterrupted current. Its TMG 400-2000 thermomagnetic release provides adjustable overload protection together with instantaneous short-circuit protection adjustable from 1000–2000 A. The four-pole configuration incorporates a fully rated neutral, making it suitable for three-phase four-wire electrical systems where the neutral requires the same current-carrying capability as the phase conductors.

With a rated operational voltage of up to 690 V AC and an ultimate short-circuit breaking capacity of 36 kA at 380–440 V AC, the 1SDA100407R1 provides robust circuit protection for demanding industrial installations. Its fixed construction and front terminal connections enable straightforward integration into generator switchboards, industrial distribution panels and electrical control assemblies.

Key Advantages

  • High-performance ABB Tmax XT moulded case circuit breaker for generator and distribution protection.
  • 400 A rated current and 400 A rated uninterrupted current.
  • 36 kA breaking capacity at 380–440 V AC.
  • TMG thermomagnetic trip unit for overload and short-circuit protection.
  • Four-pole configuration with fully rated neutral at 100% of In.
  • Fixed mounting with front terminals for convenient switchboard installation.

Key Features

  • ABB SACE Tmax XT series.
  • XT5N 400 frame configuration.
  • 400 A rated current.
  • 400 A rated uninterrupted current.
  • TMG 400-2000 thermomagnetic trip unit.
  • Instantaneous short-circuit current setting of 1000–2000 A.
  • Four-pole configuration with neutral rated at 100% of In.
  • 36 kA Icu at 380–440 V AC.
  • Rated operational voltage up to 690 V AC.
  • Fixed mounting with front terminal connections.

Reliable Generator and Distribution Protection

Moulded case circuit breakers such as the ABB XT5N protect electrical installations against damaging overload and short-circuit conditions. The TMG thermomagnetic release combines overload protection with adjustable instantaneous short-circuit protection, providing dependable protection for generators and associated low-voltage distribution circuits.

The four-pole design provides protection across all four poles and incorporates a fully rated neutral at 100% of In. Together with its compact XT5 construction, high breaking capacity and fixed front-connected arrangement, this makes the 1SDA100407R1 particularly suitable for generator switchboards, industrial distribution panels and three-phase four-wire electrical systems.

Typical Applications

  • Generator protection and generator switchboards.
  • Industrial power distribution systems.
  • Three-phase four-wire electrical installations.
  • Industrial switchboards and distribution panels.
  • Manufacturing and process facilities.
  • Commercial and infrastructure electrical distribution.

Technical Specifications

Series SACE Tmax XT
Order code 1SDA100407R1
Product type Moulded case circuit breaker
Application Generator and electrical distribution protection
Frame size XT5
Frame rating 400 A
Rated current (In) 400 A
Rated uninterrupted current (Iu) 400 A
Number of poles 4
Neutral rating 100% of In
Trip unit TMG
Release type Thermomagnetic
Instantaneous short-circuit current setting (Ii) 1000–2000 A
Current type AC / DC
Rated operational voltage 690 V AC / 750 V DC
Rated insulation voltage (Ui) 1000 V
Rated impulse withstand voltage (Uimp) 8 kV
Rated ultimate breaking capacity (Icu) at 220–240 V AC 70 kA
Rated ultimate breaking capacity (Icu) at 380–440 V AC 36 kA
Rated ultimate breaking capacity (Icu) at 500–525 V AC 25 kA
Rated ultimate breaking capacity (Icu) at 690 V AC 20 kA
Rated short-time withstand current (Icw) 6 kA
Short-circuit performance level N
Mounting version Fixed
Terminal connection Front
Standard IEC
Electrical durability 7000 cycles
Mechanical durability 20,000 cycles
Dimensions (H × W × D) 205 × 186 × 103.5 mm
Net weight approx. 5.6 kg
EAN 8056221004848

Frequently Asked Questions

What is the ABB 1SDA100407R1 used for?

The ABB 1SDA100407R1 is a four-pole moulded case circuit breaker designed for generator protection and low-voltage electrical distribution applications.

What is the rated current of the ABB 1SDA100407R1?

The breaker has a rated current and rated uninterrupted current of 400 A.

What protection does the TMG 400-2000 trip unit provide?

The TMG thermomagnetic trip unit provides overload and short-circuit protection, with an instantaneous short-circuit current setting adjustable from 1000–2000 A.

What is the breaking capacity of the ABB XT5N 400?

The 1SDA100407R1 has a rated ultimate short-circuit breaking capacity of 36 kA at 380–440 V AC, 25 kA at 500–525 V AC and 20 kA at 690 V AC.

What does In=100%In mean on this four-pole circuit breaker?

It means the neutral is fully rated at 100% of the breaker rated current, making the circuit breaker suitable for three-phase four-wire systems requiring full neutral current capability.

Trusted by Electrical Engineers Worldwide

ABB SACE Tmax XT moulded case circuit breakers are widely used in generator protection and industrial power distribution systems where dependable overload and short-circuit protection, compact installation and high breaking performance are essential.