ABB 1SDA100405R1 XT5N 630 Ekip Dip LSIG 630 A four-pole moulded case circuit breaker. Features an electronic LSIG trip unit with long-time overload, short-time short-circuit, instantaneous short-circuit and ground-fault protection. Fixed mounting version with front terminals, 690 V AC rated operational voltage and 36 kA rated service breaking capacity at 415 V AC.
£2,311.76
The ABB XT5N 630 Ekip Dip LSIG, manufacturer order code 1SDA100405R1, is a high-performance 630 A four-pole moulded case circuit breaker (MCCB) designed for reliable circuit protection in low-voltage electrical distribution systems. Part of ABB's SACE Tmax XT5 range, this industrial circuit breaker combines high-current switching capability with an electronic trip unit, fixed mounting and front terminal connections.
Equipped with an Ekip Dip LSIG electronic trip unit, the XT5N 630 provides four essential protection functions: long-time overload protection (L), short-time short-circuit protection (S), instantaneous short-circuit protection (I) and ground-fault protection (G). These functions allow electrical engineers to configure protection settings and coordinate the breaker with other protective devices within a distribution system.
The 630 A rated current makes the ABB 1SDA100405R1 suitable for substantial industrial and commercial power distribution circuits. Its four-pole configuration supports appropriately designed three-phase electrical systems requiring switching of an additional conductor, commonly the neutral.
ABB identifies this exact configuration as XT5N 630 Ekip Dip LSIG In=630 4p F F. The N breaking-capacity version provides a rated service short-circuit breaking capacity of 36 kA at 415 V AC, while the fixed mounting arrangement and front terminals support integration into compatible electrical switchboards and distribution panels.
The ABB XT5N 630 Ekip Dip LSIG is designed to provide dependable protection for high-current low-voltage electrical distribution circuits. Unlike a conventional switch disconnector, this 630 A MCCB automatically interrupts the circuit when its electronic protection system detects fault conditions exceeding the configured thresholds.
The long-time (L) protection function responds to sustained overloads that could otherwise cause excessive conductor heating or equipment damage. Its adjustable settings allow electrical engineers to coordinate the protection characteristic with the design current and current-carrying capacity of the protected circuit.
The short-time (S) protection function provides delayed short-circuit protection, where configured, helping support discrimination between upstream and downstream protective devices. This is particularly valuable in industrial distribution systems where maintaining continuity of supply to unaffected circuits is important. Selectivity must be verified using ABB's published protection curves and the prospective fault-current levels.
The instantaneous (I) protection function responds rapidly to severe short-circuit conditions, while the ground-fault (G) protection function provides an additional protective characteristic for suitable earthing arrangements. The ground-fault function must be configured according to the installation's protection design and should not be confused with a dedicated residual-current device.
The four-pole construction is suitable for appropriately designed three-phase systems where an additional conductor, commonly the neutral, must also be switched. Neutral protection settings and switching requirements depend on the earthing arrangement and applicable electrical regulations.
The fixed mounting arrangement with front terminals is intended for permanent installation in compatible electrical panels and switchboards. The breaker uses a manual toggle operating mechanism and can be equipped with compatible accessories where additional functions are required. The device itself is rated IP20, so suitable panel construction and installation measures must provide the environmental protection required by the installation.
The ABB XT5N 630 belongs to the N breaking-capacity class within the SACE Tmax XT5 family. Its short-circuit breaking performance depends on the operating voltage, making it essential to verify the electrical characteristics of the installation before selecting the breaker.
For this configuration, published rated service short-circuit breaking capacities (Ics) include 70 kA at 230 V AC, 36 kA at 415 V AC, 25 kA at 500 V AC and 20 kA at 690 V AC. These values must not be applied interchangeably across different voltages.
The rated service breaking capacity (Ics) and ultimate breaking capacity (Icu) are distinct technical characteristics. Electrical designers must confirm that the selected circuit breaker provides suitable short-circuit protection for the prospective fault current at its installation point and coordinate it with upstream and downstream equipment.
With a 1000 V rated insulation voltage, 8 kV rated impulse withstand voltage and 690 V AC rated operational voltage, the XT5N 630 is intended for a broad range of industrial low-voltage distribution applications. Final selection must always account for the installation environment, protection settings, conductor connections and applicable standards.
The ABB 1SDA100405R1 is an XT5N 630 four-pole moulded case circuit breaker with a 630 A rated current and an Ekip Dip LSIG electronic trip unit. It is designed for low-voltage electrical distribution protection.
The breaker has a 630 A rated current (In) and belongs to ABB's XT5N 630 frame range. Its electronic protection settings must be configured to suit the installation.
LSIG stands for long-time overload (L), short-time short-circuit (S), instantaneous short-circuit (I) and ground-fault (G) protection.
The ABB 1SDA100405R1 has four poles. It is suitable for appropriately designed electrical systems requiring four-pole switching and circuit protection.
The designation F F identifies the fixed circuit breaker version with front terminals, intended for permanent installation in compatible switchboards and electrical panels.
Yes. The Ekip Dip LSIG electronic trip unit includes a ground-fault (G) protection function. Its settings and application must be coordinated with the installation's earthing arrangement and protective devices.
The XT5N 630 has a published rated service short-circuit breaking capacity (Ics) of 36 kA at 415 V AC. Other voltage-dependent Ics ratings include 70 kA at 230 V, 25 kA at 500 V and 20 kA at 690 V.
The ABB 1SDA100405R1 is a moulded case circuit breaker (MCCB). It provides automatic protection against specified overload, short-circuit and ground-fault conditions, as well as manual switching functionality.
Yes. The breaker is intended for low-voltage electrical distribution applications, including appropriately engineered industrial switchboards and distribution panels. Its breaking capacity, protection settings and installation requirements must be verified.
Confirm the 630 A rated current, four-pole configuration, Ekip Dip LSIG trip unit, fixed front-terminal arrangement, voltage-dependent breaking capacity, neutral protection requirements, connection accessories and installation dimensions against the exact ABB product documentation.
The ABB XT5N 630 Ekip Dip LSIG combines 630 A four-pole circuit protection with adjustable electronic overload, short-circuit and ground-fault functions. Its 36 kA service breaking capacity at 415 V AC, fixed front-terminal configuration and established SACE Tmax XT5 platform make it a practical choice for electrical contractors, switchboard manufacturers, industrial engineers and facilities maintenance professionals.
We use cookies
We use essential cookies to run this site, your basket and checkout. With your permission we'd also like to use analytics and advertising cookies to understand how the site is used and to measure our adverts.