1SDA100382R1 ABB XT5N 400 TMA 320-3200 4-Pole Fixed Circuit Breaker InN=50%In

1SDA100382R1 ABB XT5N 400 TMA 320-3200 4-Pole Fixed Circuit Breaker InN=50%In

ABB 1SDA100382R1 is a 320 A four-pole fixed SACE Tmax XT5N 400 moulded case circuit breaker with front terminals, an adjustable TMA thermomagnetic release and neutral protection set to 50% of the phase setting.

SKU: 1SDA100382R1MPN: 1SDA100382R1
Price
List Price £1,588.09 ex VAT
Your Price (ex VAT) Save 25%
£1,191.07 25% OFF
You save £397.02 per unit
Manufacturer Lead Time Estimated Delivery 5 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £1,191.07
Trade pricing is personalised to your account

Manufacturer Lead Time

£1,191.07

Why Choose the ABB XT5N 400 TMA 320-3200 4P Circuit Breaker?

The ABB XT5N 400 TMA 320-3200 4P F F InN=50%In 1SDA100382R1 is a fixed four-pole SACE Tmax XT5 moulded case circuit breaker designed for protection of low-voltage power-distribution systems. It combines the XT5N 400 frame with a 320 A TMA thermomagnetic release and a neutral protection setting equal to 50% of the phase setting.

The TMA thermomagnetic release provides adjustable thermal overload and instantaneous magnetic short-circuit protection. The overload setting range is 224–320 A, while the instantaneous short-circuit release can be adjusted from 1600–3200 A, supporting effective coordination with cables and downstream equipment.

The 1SDA100382R1 is supplied as a fixed four-pole breaker with front terminals. Its XT5N performance class provides an ultimate short-circuit breaking capacity of 36 kA at 415 V AC, making it suitable for industrial, commercial and infrastructure distribution systems requiring switched neutral and thermomagnetic circuit protection.

Key Advantages

  • Complete ABB SACE Tmax XT5N moulded case circuit breaker.
  • 320 A TMA thermomagnetic release in an XT5 400 frame.
  • Four-pole configuration for three-phase systems with neutral.
  • Neutral protection set to 50% of the phase setting.
  • Adjustable thermal overload protection from 224–320 A.
  • Adjustable instantaneous short-circuit protection from 1600–3200 A.
  • 36 kA ultimate breaking capacity at 415 V AC.
  • Fixed mounting with front terminals for straightforward switchboard integration.

Key Features

  • ABB SACE Tmax XT series.
  • XT5N 400 frame.
  • 320 A rated release current.
  • Four poles.
  • TMA thermomagnetic trip unit.
  • Adjustable thermal overload protection.
  • Adjustable instantaneous magnetic short-circuit protection.
  • Neutral protection at 50% of phase setting.
  • Fixed execution.
  • Front terminal connections.

Adjustable Thermomagnetic Protection with 50% Neutral Protection

The ABB XT5N 400 uses a TMA thermomagnetic release to provide circuit protection without requiring an electronic trip unit. Its thermal element protects against sustained overloads with an adjustable 224–320 A setting range, while the magnetic element provides rapid short-circuit protection adjustable from 1600–3200 A.

This four-pole version incorporates neutral protection at 50% of the phase setting, making it suitable for distribution systems where the neutral conductor requires dedicated protection at a reduced current threshold. Fixed construction and front terminals simplify integration into compatible low-voltage switchboards and distribution assemblies.

Typical Applications

  • Industrial low-voltage distribution boards.
  • Main and sub-main switchboards.
  • Commercial building power distribution.
  • Three-phase four-wire distribution systems.
  • Manufacturing and process installations.
  • Transformer and installation protection.
  • Feeder and cable protection.
  • Applications requiring 50% neutral protection.

Technical Specifications

Series SACE Tmax XT
Product group T-Max XT 250 Range
ABB order code 1SDA100382R1
Product type Moulded case circuit breaker (MCCB)
Frame size XT5
Breaking-performance class N
Frame rated uninterrupted current (Iu) 400 A
Trip-unit rated current (In) 320 A
Number of poles 4
Trip unit TMA thermomagnetic release
Thermal overload setting 224–320 A
Instantaneous short-circuit setting (I3) 1600–3200 A
Neutral protection 50% of phase setting
Rated operational voltage Up to 690 V AC
Ultimate short-circuit breaking capacity (Icu) at 415 V AC 36 kA
Service short-circuit breaking capacity (Ics) at 415 V AC 36 kA
Rated short-time withstand current (Icw) 5 kA
Mounting Fixed
Terminal arrangement Front terminals
Degree of protection IP20
Standard IEC 60947-2
Dimensions (W × H × D) 186 × 205 × 103.5 mm
Net weight 5.6 kg
EAN 8056221004596

Frequently Asked Questions

What is the ABB 1SDA100382R1?

The ABB 1SDA100382R1 is an XT5N 400 fixed four-pole moulded case circuit breaker with front terminals, a 320 A TMA thermomagnetic release and neutral protection set to 50% of the phase setting.

What is the overload adjustment range of the ABB 1SDA100382R1?

The TMA thermal overload release can be adjusted from 224–320 A.

What is the short-circuit protection range?

The instantaneous magnetic short-circuit release is adjustable from 1600–3200 A.

What does InN=50%In mean on this ABB XT5 breaker?

InN=50%In indicates that the neutral-pole protection is set at 50% of the phase protection setting, providing dedicated protection for the neutral conductor.

How is the ABB 1SDA100382R1 mounted and connected?

The 1SDA100382R1 is supplied as a fixed four-pole circuit breaker with front terminals for installation in compatible low-voltage switchboards and distribution assemblies.

Trusted ABB Circuit Protection

ABB SACE Tmax XT moulded case circuit breakers combine compact construction, configurable thermomagnetic protection and dependable breaking performance for industrial, infrastructure and commercial low-voltage power-distribution systems.