1SDA100367R1 ABB XT5N 400 Ekip M Dip I 320A 3-Pole Fixed Circuit Breaker

1SDA100367R1 ABB XT5N 400 Ekip M Dip I 320A 3-Pole Fixed Circuit Breaker

ABB 1SDA100367R1 is a 320 A three-pole fixed SACE Tmax XT5N 400 moulded case circuit breaker with front terminals and an Ekip M Dip I solid-state electronic release for instantaneous short-circuit protection.

SKU: 1SDA100367R1MPN: 1SDA100367R1
Price
List Price £1,211.67 ex VAT
Your Price (ex VAT) Save 25%
£908.75 25% OFF
You save £302.92 per unit
Manufacturer Lead Time Estimated Delivery 5 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £908.75
Trade pricing is personalised to your account

Manufacturer Lead Time

£908.75

Why Choose the ABB XT5N 400 Ekip M Dip I 320A 3P Circuit Breaker?

The ABB XT5N 400 Ekip M Dip I In=320A 3P F F 1SDA100367R1 is a fixed three-pole SACE Tmax XT5 moulded case circuit breaker designed for motor and low-voltage AC circuit protection. It combines an XT5N 400 frame with a 320 A Ekip M Dip I solid-state electronic release.

The Ekip M Dip I release is designed for applications where electronic instantaneous short-circuit protection is required, particularly motor circuits where overload protection may be provided separately by the motor protection system. Its electronic architecture provides accurate fault detection while retaining the compact and modular construction of the SACE Tmax XT platform.

The 1SDA100367R1 is supplied as a fixed three-pole breaker with front terminals. Its N performance level provides both ultimate and service short-circuit breaking capacities of 36 kA at 415 V AC, while ratings of 690 V AC operational voltage, 1000 V insulation voltage and 8 kV impulse withstand voltage support demanding industrial installations.

Key Advantages

  • Complete ABB SACE Tmax XT5N moulded case circuit breaker.
  • 320 A Ekip M Dip I electronic release for motor-oriented circuit protection.
  • XT5 400 A frame with N short-circuit performance level.
  • Three-pole configuration for three-phase AC applications.
  • Electronic instantaneous short-circuit protection.
  • 36 kA Icu and Ics at 415 V AC.
  • Fixed mounting with front terminals for straightforward switchboard integration.
  • Suitable for applications where motor overload protection is coordinated separately.

Key Features

  • ABB SACE Tmax XT series.
  • XT5N 400 frame.
  • 320 A rated trip-unit current.
  • 400 A rated uninterrupted frame current.
  • Three poles.
  • Ekip M Dip I solid-state electronic release.
  • Instantaneous (I) protection against short-circuit currents.
  • Fixed execution.
  • Front terminal connections.
  • Compliant with IEC 60947-2.

Electronic Short-Circuit Protection for Motor Circuits

The ABB Ekip M Dip I release is designed to provide electronic instantaneous protection against high short-circuit currents. This makes the XT5N configuration particularly suitable for motor circuits where overload protection is handled by a separate motor protection device, allowing the circuit breaker to concentrate on rapid interruption of damaging fault currents.

With a 320 A electronic release, 36 kA breaking capacity at 415 V AC and fixed front-terminal construction, the 1SDA100367R1 provides a robust protection solution for motor control centres, industrial switchboards and other three-phase power applications requiring an XT5-class MCCB.

Typical Applications

  • Industrial motor circuits.
  • Motor control centres (MCCs).
  • Industrial low-voltage switchboards.
  • Manufacturing and process installations.
  • Pumps, fans and compressor circuits.
  • Conveyor and material-handling systems.
  • Three-phase machinery power circuits.
  • Applications using separate motor overload protection.

Technical Specifications

Series SACE Tmax XT
Product group T-Max XT 250 Range
ABB order code 1SDA100367R1
Product type Moulded case circuit breaker (MCCB)
Frame size XT5
Breaking-performance class N
Rated uninterrupted current (Iu) 400 A
Rated current (In) 320 A
Number of poles 3
Trip unit Ekip M Dip I
Release type Solid-state electronic
Protection function Instantaneous short-circuit (I)
Rated operational voltage 690 V AC
Rated insulation voltage (Ui) 1000 V
Rated impulse withstand voltage (Uimp) 8 kV
Ultimate short-circuit breaking capacity (Icu) at 415 V AC 36 kA
Service short-circuit breaking capacity (Ics) at 415 V AC 36 kA
Rated short-time withstand current (Icw) 5 kA
Power loss 11.6 W
Mounting Fixed
Terminal connection Front
Standard IEC 60947-2
Dimensions (W × H × D) 140 × 205 × 103.5 mm
Net weight 4.82 kg
EAN 8056221004442

Frequently Asked Questions

What is the ABB 1SDA100367R1?

The ABB 1SDA100367R1 is an XT5N 400 fixed three-pole moulded case circuit breaker with front terminals and a 320 A Ekip M Dip I solid-state electronic release.

What is the rated current of the ABB XT5N 1SDA100367R1?

The Ekip M Dip I release has a rated current of 320 A, while the XT5 frame has a rated uninterrupted current of 400 A.

What protection does the Ekip M Dip I release provide?

The Ekip M Dip I provides electronic instantaneous short-circuit protection and is particularly suited to motor applications where overload protection is provided separately.

What is the breaking capacity of the ABB 1SDA100367R1?

The XT5N configuration has an ultimate and service short-circuit breaking capacity of 36 kA at 415 V AC.

How is the ABB 1SDA100367R1 mounted and connected?

The 1SDA100367R1 is supplied as a fixed three-pole circuit breaker with front terminals for integration into compatible low-voltage switchboards, motor control centres and distribution assemblies.

Trusted ABB Circuit Protection

ABB SACE Tmax XT moulded case circuit breakers combine compact construction, solid-state electronic protection and dependable short-circuit performance for motor control, industrial machinery and low-voltage power-distribution systems.