Standard delivery
£8 ex VAT · free over £200UK parcel delivery is £8 ex VAT, or free on orders over £200 ex VAT.
Heavier items may be charged at a weight-based or pallet rate, shown at checkout.
ABB 1SDA100262R1 XT4V 250 3-pole fixed MCCB breaking part with front terminals, 250 A rated uninterrupted current and 150 kA short-circuit breaking capacity at 415 V AC for high-fault-level low-voltage distribution applications.
£765.38
The ABB 1SDA100262R1 is a Tmax XT4V 250 breaking part designed for use within ABB's XT4 moulded case circuit breaker platform. It features a 250 A rated uninterrupted current, 3-pole fixed construction and front terminals, providing the high-performance interruption section required when assembling a compatible XT4V circuit breaker.
The V short-circuit performance level is engineered for electrical distribution systems with high prospective fault currents. The XT4V 250 provides a rated ultimate short-circuit breaking capacity of 150 kA at 415 V AC, making it suitable for demanding industrial, commercial and infrastructure installations where robust fault interruption is essential.
The 1SDA100262R1 is supplied as the breaking part rather than a complete protective circuit breaker. A compatible ABB XT4 trip unit must be selected separately to create the required complete breaker configuration, allowing the protection characteristics to be matched to the electrical installation while retaining the XT4V platform's high breaking capacity.
The breaking part forms the interruption section of a modular ABB Tmax XT4V circuit breaker assembly. Its function is to safely interrupt fault current when operated by the associated protection trip unit, while the separately selected trip unit determines the overload and short-circuit protection characteristics required for the installation.
With rated service and ultimate short-circuit breaking capacities of 150 kA at 415 V AC, the XT4V 250 platform is designed for electrical systems where prospective fault currents can be substantially higher than those encountered in conventional distribution applications. Combining the 1SDA100262R1 with a compatible ABB XT4 trip unit creates a complete protective circuit breaker tailored to the required application.
| Series | Tmax XT |
|---|---|
| Product range | T-Max XT 250 Range |
| Order code | 1SDA100262R1 |
| EAN | 8056221003162 |
| Product type | MCCB breaking part |
| Frame | XT4 |
| Rated uninterrupted current (Iu) | 250 A |
| Short-circuit performance level | V |
| Rated operational voltage | 690 V AC / 750 V DC |
| Rated insulation voltage (Ui) | 1,000 V |
| Rated impulse withstand voltage (Uimp) | 8 kV |
| Rated service short-circuit breaking capacity (Ics) at 380 V AC | 150 kA |
| Rated service short-circuit breaking capacity (Ics) at 415 V AC | 150 kA |
| Rated service short-circuit breaking capacity (Ics) at 440 V AC | 150 kA |
| Rated service short-circuit breaking capacity (Ics) at 500 V AC | 85 kA |
| Rated service short-circuit breaking capacity (Ics) at 525 V AC | 70 kA |
| Rated service short-circuit breaking capacity (Ics) at 690 V AC | 50 kA |
| Rated ultimate short-circuit breaking capacity (Icu) at 380 V AC | 150 kA |
| Rated ultimate short-circuit breaking capacity (Icu) at 415 V AC | 150 kA |
| Rated ultimate short-circuit breaking capacity (Icu) at 440 V AC | 150 kA |
| Rated ultimate short-circuit breaking capacity (Icu) at 500 V AC | 85 kA |
| Rated ultimate short-circuit breaking capacity (Icu) at 525 V AC | 70 kA |
| Rated ultimate short-circuit breaking capacity (Icu) at 690 V AC | 50 kA |
| Number of poles | 3 |
| Installation | Fixed |
| Terminal configuration | Front terminals |
| Standard | IEC |
| Dimensions (W × H × D) | 105 × 160 × 82.5 mm |
| Electrical durability | 10,000 cycles |
| Mechanical durability | 25,000 cycles |
| Net weight | 8.2 kg |
The ABB 1SDA100262R1 is an XT4V 250 breaking part for the Tmax XT4 moulded case circuit breaker platform, featuring a 250 A rated uninterrupted current, fixed 3-pole construction and front terminals.
No. The 1SDA100262R1 is the breaking part of an XT4V circuit breaker assembly. A compatible ABB XT4 trip unit must be selected separately to create the required complete protective circuit breaker.
The XT4V 250 breaking part has rated service and ultimate short-circuit breaking capacities of 150 kA at 415 V AC, making it suitable for installations with very high prospective fault currents.
The XT4V 250 breaking part has a rated uninterrupted current of 250 A.
The 1SDA100262R1 has a fixed 3-pole configuration with front terminals and is designed for integration into a compatible ABB Tmax XT4V circuit breaker assembly.
ABB Tmax XT moulded case circuit breaker technology combines compact construction, modular protection options and high short-circuit performance, with the XT4V platform providing robust fault interruption for demanding industrial, commercial and infrastructure low-voltage distribution systems.