1SDA100255R1 ABB XT4H 250 Ekip Dip LSIG 250 A 4-Pole Circuit Breaker

1SDA100255R1 ABB XT4H 250 Ekip Dip LSIG 250 A 4-Pole Circuit Breaker

ABB 1SDA100255R1 SACE Tmax XT4H 250 fixed 4-pole moulded-case circuit breaker with a 250 A Ekip Dip LSIG electronic trip unit, front terminals and 70 kA breaking capacity at 380–415 V AC for demanding low-voltage power distribution protection.

SKU: 1SDA100255R1MPN: 1SDA100255R1
Price
List Price £3,134.71 ex VAT
Your Price (ex VAT) Save 25%
£2,351.03 25% OFF
You save £783.68 per unit
Manufacturer Lead Time Estimated Delivery 7 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £2,351.03
Trade pricing is personalised to your account

Manufacturer Lead Time

£2,351.03

Why Choose the ABB 1SDA100255R1 XT4H 250 Ekip Dip LSIG Circuit Breaker?

The ABB 1SDA100255R1 is a high-performance SACE Tmax XT4H 250 moulded-case circuit breaker (MCCB) designed for comprehensive protection of low-voltage AC power distribution systems. This fixed, four-pole circuit breaker combines the compact XT4 platform with an Ekip Dip LSIG electronic trip unit rated at 250 A, providing protection against overloads, short circuits and earth faults.

As part of the ABB SACE Tmax XT series, the XT4H combines high short-circuit performance with microprocessor-based electronic protection for industrial, commercial and infrastructure applications. The Ekip Dip LSIG release provides long-time overload, short-time selective short-circuit, instantaneous short-circuit and earth-fault protection, supporting effective coordination of feeders, cables and connected electrical equipment.

The 1SDA100255R1 is supplied in a fixed, 4-pole configuration with front terminals. Its H performance class provides a rated short-circuit breaking capacity of 70 kA at 380–415 V AC, while the 250 A Ekip Dip LSIG release provides instantaneous protection adjustment from approximately 250–2,500 A, making it suitable for demanding distribution systems with high prospective fault currents.

Key Advantages

  • High-performance ABB SACE Tmax XT4H 250 moulded-case circuit breaker for demanding low-voltage distribution.
  • 250 A Ekip Dip LSIG electronic trip unit provides configurable microprocessor-based protection.
  • LSIG protection functions cover overload, selective short circuit, instantaneous short circuit and earth fault.
  • 4-pole fixed configuration supports four-pole AC distribution applications.
  • Front terminals provide convenient connections for conventional switchboard installation.
  • 70 kA breaking capacity at 380–415 V AC supports systems with high prospective fault levels.
  • Electronic trip technology provides greater protection flexibility than conventional fixed thermal-magnetic releases.
  • Compatible with the broad ABB SACE Tmax XT accessory and installation ecosystem.

Key Features

  • ABB SACE Tmax XT4H 250 moulded-case circuit breaker.
  • 250 A rated current.
  • 250 A Ekip Dip LSIG solid-state electronic release.
  • 4-pole configuration.
  • Fixed mounting.
  • Front terminals.
  • Long-time overload protection (L).
  • Short-time selective short-circuit protection (S).
  • Instantaneous short-circuit protection (I).
  • Earth-fault protection (G).
  • Instantaneous protection adjustment approximately 250–2,500 A.
  • H high-breaking-capacity performance level.
  • 70 kA breaking capacity at 380–415 V AC.
  • Microprocessor-based protection for AC distribution systems.

High-Performance LSIG Protection for Power Distribution

The ABB Ekip Dip LSIG electronic trip unit uses microprocessor technology to combine multiple protection functions within a single compact circuit breaker. Long-time protection responds to sustained overload conditions, short-time protection supports selective coordination, instantaneous protection rapidly responds to severe short circuits, and the earth-fault function adds protection against ground-fault currents.

The SACE Tmax XT4H platform is designed for installations where higher prospective short-circuit currents demand increased interruption performance. With its 250 A electronic release, four-pole construction, fixed mounting, front terminals and 70 kA breaking capacity at 380–415 V AC, the 1SDA100255R1 provides a robust solution for demanding low-voltage switchboards and power distribution assemblies.

Typical Applications

  • Low-voltage power distribution switchboards.
  • Industrial main and sub-distribution systems.
  • Commercial building electrical distribution.
  • Manufacturing and production facilities.
  • Transformer and generator protection.
  • Infrastructure and utility electrical systems.
  • Four-pole switchgear and distribution assemblies.
  • Circuits requiring high breaking capacity and electronic earth-fault protection.

Technical Specifications

Series SACE Tmax XT
Product range T-Max XT 250 Range
Order code 1SDA100255R1
Product type Moulded-case circuit breaker (MCCB)
Frame XT4
Performance level H
Rated current 250 A
Trip unit Ekip Dip LSIG
Trip-unit rated current (In) 250 A
Instantaneous protection adjustment approx. 250–2,500 A
Number of poles 4
Current type AC
Breaking capacity at 380–415 V AC 70 kA
Protection functions L, S, I and G
Release technology Solid-state electronic / microprocessor
Mounting execution Fixed
Terminal arrangement Front terminals
Application Transformer, generator and installation protection
Net weight 3.5 kg
GTIN / EAN 8056221003094
Commodity code 85362090

Frequently Asked Questions

What is the ABB 1SDA100255R1 used for?

The ABB 1SDA100255R1 is a SACE Tmax XT4H 250 moulded-case circuit breaker designed to protect low-voltage AC distribution systems against overloads, short circuits and earth faults, including transformer, generator and installation protection applications.

What is the current rating of the ABB 1SDA100255R1?

The circuit breaker is rated at 250 A and is equipped with an Ekip Dip LSIG electronic trip unit rated at 250 A.

What does LSIG protection mean?

LSIG provides long-time overload, short-time selective short-circuit, instantaneous short-circuit and earth-fault protection, giving the breaker comprehensive electronic protection for low-voltage distribution systems.

What is the breaking capacity of the ABB 1SDA100255R1?

The XT4H performance level provides a short-circuit breaking capacity of 70 kA at 380–415 V AC, making it suitable for demanding installations with high prospective fault currents.

How is the ABB 1SDA100255R1 installed?

The breaker is supplied in a fixed, 4-pole configuration with front terminals for installation in low-voltage switchboards, distribution panels and industrial electrical assemblies.

Trusted Protection for High-Fault-Level Distribution Systems

ABB SACE Tmax XT moulded-case circuit breakers combine compact construction, high short-circuit performance and configurable electronic protection to safeguard modern industrial, commercial and infrastructure power distribution systems.