1SDA100190R1 ABB XT4N 250 Ekip Dip LSI 250 A 4-Pole Circuit Breaker

1SDA100190R1 ABB XT4N 250 Ekip Dip LSI 250 A 4-Pole Circuit Breaker

ABB 1SDA100190R1 SACE Tmax XT4N 250 fixed 4-pole moulded-case circuit breaker with a 250 A Ekip Dip LSI electronic trip unit, front terminals and 36 kA breaking capacity at 380–415 V AC for low-voltage power distribution protection.

SKU: 1SDA100190R1MPN: 1SDA100190R1
Price
List Price £2,567.53 ex VAT
Your Price (ex VAT) Save 25%
£1,925.65 25% OFF
You save £641.88 per unit
Manufacturer Lead Time Estimated Delivery 3 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £1,925.65
Trade pricing is personalised to your account

Manufacturer Lead Time

£1,925.65

Why Choose the ABB 1SDA100190R1 XT4N 250 Ekip Dip LSI Circuit Breaker?

The ABB 1SDA100190R1 is a SACE Tmax XT4N 250 moulded-case circuit breaker (MCCB) designed for reliable protection of low-voltage AC power distribution systems. This fixed, four-pole circuit breaker features an Ekip Dip LSI solid-state electronic trip unit rated at 250 A, providing configurable protection against overloads and short circuits in demanding industrial, commercial and infrastructure installations.

As part of the ABB SACE Tmax XT series, the XT4N combines compact construction with microprocessor-based electronic protection. The Ekip Dip LSI release provides long-time overload, short-time selective short-circuit and instantaneous short-circuit protection, enabling effective protection coordination between feeders, cables and downstream electrical equipment.

The 1SDA100190R1 is supplied in a fixed, 4-pole configuration with front terminals and has a rated uninterrupted current of 250 A. The XT4N performance class provides a rated ultimate and service short-circuit breaking capacity of 36 kA at 380–415 V AC, while its 690 V AC rated operational voltage makes it suitable for a broad range of low-voltage distribution applications.

Key Advantages

  • Complete ABB SACE Tmax XT4N 250 moulded-case circuit breaker for low-voltage power distribution.
  • 250 A Ekip Dip LSI electronic trip unit for configurable microprocessor-based protection.
  • LSI protection functions cover long-time overload, short-time selective short circuit and instantaneous short circuit.
  • 4-pole fixed configuration for four-pole AC distribution applications.
  • Front terminals provide straightforward switchboard connection.
  • 36 kA breaking capacity at 380–415 V AC for demanding distribution systems.
  • 690 V AC rated operational voltage supports a wide range of low-voltage installations.
  • High mechanical and electrical endurance for dependable service in industrial switchgear.

Key Features

  • ABB SACE Tmax XT4N 250 moulded-case circuit breaker.
  • 250 A rated uninterrupted current.
  • Ekip Dip LSI 250 A solid-state electronic release.
  • 4-pole configuration.
  • Fixed mounting.
  • Front terminals.
  • Long-time overload protection (L).
  • Short-time selective short-circuit protection (S).
  • Instantaneous short-circuit protection (I).
  • Instantaneous protection adjustment approximately 250–2,500 A.
  • 690 V AC rated operational voltage.
  • 1,000 V AC rated insulation voltage.
  • 8 kV rated impulse withstand voltage.
  • 50 / 60 Hz rated frequency.
  • Designed and specified for IEC low-voltage applications.

Reliable LSI Protection for Power Distribution

The ABB Ekip Dip electronic trip unit uses microprocessor-based technology to monitor current through the circuit breaker and initiate tripping when configured thresholds are exceeded. Its LSI functionality combines long-time overload, short-time selective short-circuit and instantaneous short-circuit protection, helping engineers coordinate protective devices while safeguarding cables, feeders and connected equipment.

The SACE Tmax XT4 platform combines compact dimensions, high breaking performance and flexible installation with ABB's electronic protection technology. With its four-pole construction, fixed mounting and front terminals, the 1SDA100190R1 is particularly suitable for switchboards and distribution assemblies requiring dependable isolation and coordinated protection at currents up to 250 A.

Typical Applications

  • Low-voltage power distribution switchboards.
  • Industrial feeder and distribution-circuit protection.
  • Commercial building electrical distribution.
  • Manufacturing and production facilities.
  • Machinery and automation power distribution.
  • Infrastructure electrical systems.
  • Four-pole distribution and switchgear assemblies.
  • Transformer, generator and installation protection applications.

Technical Specifications

Series SACE Tmax XT
Product range T-Max XT 250 Range
Order code 1SDA100190R1
Product type Moulded-case circuit breaker (MCCB)
Frame XT4
Breaking-capacity class N
Rated uninterrupted current (Iu) 250 A
Trip unit Ekip Dip LSI
Trip-unit rated current (In) 250 A
Instantaneous protection range approx. 250–2,500 A
Number of poles 4
Rated operational voltage (Ue) 690 V AC
Rated insulation voltage (Ui) 1,000 V AC
Rated impulse withstand voltage (Uimp) 8 kV
Rated frequency 50 / 60 Hz
Rated ultimate breaking capacity (Icu) at 380–415 V AC 36 kA
Rated service breaking capacity (Ics) at 380–415 V AC 36 kA
Protection functions L, S and I
Release technology Solid-state electronic
Mounting execution Fixed
Terminal arrangement Front terminals
Dimensions (H × W × D) 160 × 140 × 82.5 mm
Power loss at rated operating conditions 16.4 W per pole
Mechanical endurance 25,000 operations
Electrical endurance 8,000 operations
Standards IEC
Net weight 3.5 kg
GTIN / EAN 8056221002448

Frequently Asked Questions

What is the ABB 1SDA100190R1 used for?

The ABB 1SDA100190R1 is a SACE Tmax XT4N 250 moulded-case circuit breaker designed to provide overload and short-circuit protection for low-voltage AC power distribution systems.

What is the current rating of the ABB 1SDA100190R1?

The circuit breaker has a rated uninterrupted current of 250 A and is equipped with an Ekip Dip LSI electronic trip unit rated at 250 A.

What does LSI protection mean?

LSI provides long-time overload, short-time selective short-circuit and instantaneous short-circuit protection, allowing coordinated electronic protection of low-voltage distribution circuits and connected equipment.

What is the breaking capacity of the ABB 1SDA100190R1?

The XT4N has a rated ultimate and service short-circuit breaking capacity of 36 kA at 380–415 V AC.

How is the ABB 1SDA100190R1 installed?

The breaker is supplied in a fixed, 4-pole configuration with front terminals for installation in low-voltage switchboards, distribution panels and industrial electrical assemblies.

Trusted Protection for Low-Voltage Distribution

ABB SACE Tmax XT moulded-case circuit breakers combine compact construction, high breaking performance and configurable electronic protection to safeguard modern industrial, commercial and infrastructure power distribution systems.