1SDA100178R1 ABB XT4N 160 Ekip Dip LSIG In=100A 3p F F MCCB

1SDA100178R1 ABB XT4N 160 Ekip Dip LSIG In=100A 3p F F MCCB

ABB 1SDA100178R1 is a Tmax XT4N 160 three-pole fixed moulded case circuit breaker with front terminals and a 100 A Ekip Dip LSIG electronic trip unit for low-voltage electrical distribution protection.

SKU: 1SDA100178R1MPN: 1SDA100178R1
Price
List Price £1,854.82 ex VAT
Your Price (ex VAT) Save 25%
£1,391.12 25% OFF
You save £463.71 per unit
Manufacturer Lead Time Estimated Delivery 3 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £1,391.12
Trade pricing is personalised to your account

Manufacturer Lead Time

£1,391.12

Why Choose the ABB XT4N 160 Ekip Dip LSIG In=100A 3p F F 1SDA100178R1?

The ABB 1SDA100178R1 is a Tmax XT4N moulded case circuit breaker (MCCB) designed for dependable protection of low-voltage electrical distribution systems. Supplied as a complete three-pole circuit breaker with an Ekip Dip LSIG electronic trip unit, it combines a 100 A rated trip current with configurable electronic protection for industrial and commercial installations.

Part of the advanced ABB SACE Tmax XT range, the XT4N 160 uses an electronic Ekip Dip release to provide long-time, short-time, instantaneous and ground-fault protection. These LSIG functions allow the breaker to protect against overloads, short circuits and earth faults while supporting effective protection coordination within low-voltage distribution systems.

The 1SDA100178R1 is a fixed, three-pole XT4N 160 breaker with front terminals and a rated current of 100 A. Its compact construction, electronic protection and 690 V AC rated operational voltage make it well suited to switchboards, distribution panels and industrial power systems where reliable circuit protection is essential.

Key Advantages

  • Complete ABB Tmax XT4N moulded case circuit breaker for low-voltage distribution.
  • 100 A Ekip Dip electronic trip unit for accurate circuit protection.
  • LSIG protection covering overload, short-time short-circuit, instantaneous short-circuit and ground-fault conditions.
  • Three-pole fixed configuration with front terminals for switchboard installation.
  • 690 V AC rated operational voltage suitable for demanding industrial distribution systems.
  • Electronic protection settings support effective coordination with upstream and downstream protective devices.

Key Features

  • ABB SACE Tmax XT4N 160 circuit breaker.
  • 100 A rated Ekip Dip trip current (In).
  • Three-pole configuration.
  • LSIG electronic protection: long-time, short-time, instantaneous and ground-fault functions.
  • Fixed mounting arrangement.
  • Front terminals for main circuit connections.
  • N breaking-capacity performance level.
  • Electronic Ekip Dip protection for configurable fault and overload protection.
  • Designed for AC low-voltage electrical distribution applications.

Advanced LSIG Protection for Electrical Distribution

Moulded case circuit breakers protect electrical installations by automatically interrupting current when abnormal operating conditions occur. The electronic Ekip Dip release used by the ABB XT4N enables more precise and configurable protection than conventional fixed thermal-magnetic protection, making it suitable for modern industrial power distribution systems.

With LSIG functionality, the 1SDA100178R1 provides long-time protection against sustained overloads, short-time protection for coordinated short-circuit response, instantaneous protection against severe short circuits and ground-fault protection for earth-fault conditions. This comprehensive protection package makes the breaker suitable for feeders, distribution circuits and other critical low-voltage applications.

Typical Applications

  • Industrial low-voltage switchboards.
  • Main and sub-distribution panels.
  • Commercial electrical distribution systems.
  • Manufacturing and process industry power systems.
  • Feeder and distribution circuit protection.
  • Plant and machinery electrical distribution.

Technical Specifications

Series SACE Tmax XT
Product group T-Max XT 250 Range
ABB order code 1SDA100178R1
Product type Moulded case circuit breaker (MCCB)
Frame XT4
Performance level N
Frame designation XT4N 160
Trip unit Ekip Dip LSIG
Protection functions LSIG
Long-time protection L
Short-time protection S
Instantaneous protection I
Ground-fault protection G
Rated trip current (In) 100 A
Rated operational voltage 690 V AC
Number of poles 3
Mounting Fixed
Terminal arrangement Front terminals
Protection rating IP20
Net weight approx. 2.5 kg
Application Low-voltage circuit protection and power distribution

Frequently Asked Questions

What is the ABB 1SDA100178R1?

The ABB 1SDA100178R1 is a Tmax XT4N 160 three-pole moulded case circuit breaker with a 100 A Ekip Dip LSIG electronic trip unit, fixed mounting and front terminals.

What protection functions does the Ekip Dip LSIG trip unit provide?

The Ekip Dip LSIG provides long-time, short-time, instantaneous and ground-fault protection, covering overloads, short circuits and earth-fault conditions.

What is the rated current of the ABB 1SDA100178R1?

The circuit breaker is equipped with an Ekip Dip electronic trip unit with a rated current, In, of 100 A.

How many poles does the 1SDA100178R1 have?

The ABB 1SDA100178R1 is a three-pole circuit breaker designed for three-phase low-voltage electrical distribution applications.

How is the ABB XT4N 160 1SDA100178R1 installed?

This model is supplied in a fixed configuration with front terminals, making it suitable for installation in low-voltage switchboards and electrical distribution panels.

Trusted Circuit Protection from ABB

ABB SACE Tmax XT moulded case circuit breakers combine compact construction with advanced electronic protection to provide dependable circuit protection and power distribution for modern industrial and commercial electrical installations.