1SDA100175R1 ABB XT4N 250 Ekip Dip LSI 250 A 3-Pole MCCB

1SDA100175R1 ABB XT4N 250 Ekip Dip LSI 250 A 3-Pole MCCB

ABB 1SDA100175R1 is a 250 A SACE Tmax XT4N three-pole fixed moulded case circuit breaker with front terminals and an Ekip Dip LSI electronic trip unit for low-voltage AC power distribution protection.

SKU: 1SDA100175R1MPN: 1SDA100175R1
Price
List Price £1,974.70 ex VAT
Your Price (ex VAT) Save 25%
£1,481.03 25% OFF
You save £493.68 per unit
Manufacturer Lead Time Estimated Delivery 6 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £1,481.03
Trade pricing is personalised to your account

Manufacturer Lead Time

£1,481.03

Why Choose the ABB 1SDA100175R1 XT4N 250 Circuit Breaker?

The ABB 1SDA100175R1 is a SACE Tmax XT4N 250 moulded case circuit breaker designed for dependable protection of low-voltage AC power distribution systems. Part of the ABB SACE Tmax XT range, this fixed three-pole breaker combines the compact XT4 frame with an Ekip Dip LSI electronic trip unit for configurable overload and short-circuit protection.

Rated at 250 A, the breaker incorporates LSI protection functions covering long-time overload, short-time short-circuit and instantaneous short-circuit protection. The long-time protection setting covers 100–250 A, while the short-time and instantaneous thresholds provide adjustable protection for coordinating the breaker with upstream and downstream protective devices.

The XT4N designation identifies the normal breaking-capacity version of the XT4 platform, while the 3p F F configuration specifies a three-pole, fixed circuit breaker with front terminals. With a rated operational voltage of up to 690 V AC and an ultimate short-circuit breaking capacity of 36 kA at 415 V AC, the 1SDA100175R1 is well suited to industrial, commercial and infrastructure distribution systems.

Key Advantages

  • Complete ABB SACE Tmax XT4N 250 moulded case circuit breaker for low-voltage distribution protection.
  • 250 A rated current with Ekip Dip electronic protection.
  • LSI protection provides long-time, short-time and instantaneous fault protection.
  • 100–250 A long-time protection setting range supports flexible circuit coordination.
  • 36 kA breaking capacity at 415 V AC for robust short-circuit protection.
  • Fixed three-pole configuration with front terminals for conventional switchboard installation.
  • Compact XT4 construction supports space-efficient electrical distribution assemblies.

Key Features

  • ABB SACE Tmax XT4 moulded case circuit breaker.
  • XT4N 250 configuration.
  • Ekip Dip LSI solid-state electronic trip unit.
  • 250 A rated current.
  • Three-pole configuration.
  • Fixed mounting arrangement.
  • Front terminals for power connections.
  • Long-time overload protection.
  • Short-time short-circuit protection.
  • Instantaneous short-circuit protection.
  • Suitable for low-voltage AC power distribution systems.

Electronic MCCB Protection for Low-Voltage Distribution

Moulded case circuit breakers protect electrical distribution circuits against overload and short-circuit conditions while also providing circuit isolation. The ABB SACE Tmax XT4 platform combines a compact 250 A frame with electronic trip technology, providing accurate protection settings and dependable fault interruption for modern low-voltage distribution systems.

The Ekip Dip LSI release provides long-time protection against sustained overloads, short-time protection for coordinated response to short-circuit conditions and instantaneous protection against severe fault currents. Combined with the XT4N breaking capacity, fixed mounting and front-terminal configuration, the 1SDA100175R1 provides a versatile solution for protecting feeders and distribution circuits up to 250 A.

Typical Applications

  • Industrial low-voltage distribution boards.
  • Commercial electrical switchboards.
  • Three-phase feeder circuit protection.
  • Main and sub-distribution panels.
  • Manufacturing and process-industry electrical systems.
  • Building services and infrastructure power distribution.

Technical Specifications

Series SACE Tmax XT
Product group T-Max XT 250 Range
Order code 1SDA100175R1
Product type Moulded case circuit breaker (MCCB)
Frame XT4
Frame rating 250 A
Breaking-capacity class N
Rated current 250 A
Long-time protection setting 100–250 A
Short-time protection setting 1–10 × In
Instantaneous protection setting 1–10 × In
Rated operational voltage Up to 690 V AC
Ultimate breaking capacity at 415 V AC 36 kA
Number of poles 3
Trip unit Ekip Dip LSI
Protection functions LSI
Long-time protection L
Short-time protection S
Instantaneous protection I
Mounting Fixed
Terminals Front terminals
Application AC power distribution
Standard IEC

Frequently Asked Questions

What is the ABB 1SDA100175R1?

The ABB 1SDA100175R1 is an XT4N 250 three-pole moulded case circuit breaker with a 250 A Ekip Dip LSI electronic trip unit, fixed mounting and front terminals.

What protection functions does the Ekip Dip LSI trip unit provide?

The Ekip Dip LSI trip unit provides long-time, short-time and instantaneous protection, protecting the circuit against sustained overloads and short-circuit fault conditions while supporting protection coordination.

What is the current setting range of the ABB 1SDA100175R1?

The breaker has a rated current of 250 A, with its long-time protection setting adjustable across 100–250 A.

What does 3p F F mean on the ABB 1SDA100175R1?

The designation identifies a three-pole, fixed circuit breaker with front terminals, making it suitable for conventional three-phase switchboard and distribution-panel installations.

What is the breaking capacity of the ABB XT4N 250?

The XT4N 250 configuration provides an ultimate short-circuit breaking capacity of 36 kA at 415 V AC, making it suitable for a wide range of industrial and commercial low-voltage distribution applications.

Trusted Circuit Protection from ABB

ABB SACE Tmax XT moulded case circuit breakers combine compact construction, configurable electronic protection and dependable interruption performance, providing flexible circuit protection for industrial, commercial and infrastructure low-voltage distribution systems.