ABB 1SDA100070R1 XT2H 160 is a 10 A three-pole fixed moulded case circuit breaker with front terminals, an Ekip Dip LIG electronic trip unit and 70 kA ultimate and service breaking capacity at 415 V AC.
£1,056.12
The ABB 1SDA100070R1 is a high-performance three-pole moulded case circuit breaker (MCCB) from the ABB SACE Tmax XT2 range, designed for dependable protection of low-voltage AC distribution systems. Rated at 10 A, it combines the compact XT2H 160 frame with an Ekip Dip LIG electronic trip unit for overload, instantaneous short-circuit and ground-fault protection.
The Ekip Dip LIG release provides long-time (L), instantaneous (I) and ground-fault (G) protection functions. Its electronic protection architecture enables reliable response to sustained overloads and severe short circuits, while the G function provides dedicated ground-fault protection for applications where earth-fault detection and disconnection are required.
The 1SDA100070R1 is supplied as a fixed three-pole circuit breaker with front terminals and supports operating voltages up to 690 V AC. The XT2H performance level delivers both an ultimate and service short-circuit breaking capacity of 70 kA at 415 V AC, providing substantial fault interruption performance in a compact MCCB format.
The ABB Ekip Dip LIG trip unit combines three complementary electronic protection functions within the compact Tmax XT2 platform. Long-time protection responds to sustained overload conditions, instantaneous protection provides rapid interruption of severe short circuits, and the ground-fault function supports protection against faults involving current flowing towards earth. This combination makes the breaker particularly useful where overcurrent and ground-fault protection are required from the same MCCB.
The XT2H performance level is designed for installations with substantial prospective short-circuit currents. With 70 kA Icu and Ics at 415 V AC, a 10 A Ekip Dip LIG release and fixed front-terminal construction, the 1SDA100070R1 provides high fault interruption capability while retaining the compact dimensions of the XT2 frame.
| Series | SACE Tmax XT / T-Max XT 250 Range |
|---|---|
| ABB order code | 1SDA100070R1 |
| Product type | Moulded case circuit breaker |
| Frame | XT2H 160 |
| Frame size | XT2 |
| Rated uninterrupted frame current (Iu) | 160 A |
| Rated trip current (In) | 10 A |
| Trip unit | Ekip Dip LIG electronic release |
| Protection functions | Long-time (L), instantaneous (I) and ground-fault (G) |
| Instantaneous short-circuit protection adjustment | 10–100 A |
| Number of poles | 3 |
| Performance level | H |
| Rated operational voltage | 690 V AC |
| Rated insulation voltage (Ui) | 1000 V |
| Rated impulse withstand voltage (Uimp) | 8 kV |
| Ultimate breaking capacity (Icu) at 220–240 V AC | 100 kA |
| Ultimate breaking capacity (Icu) at 380 V AC | 70 kA |
| Ultimate breaking capacity (Icu) at 415 V AC | 70 kA |
| Ultimate breaking capacity (Icu) at 440 V AC | 65 kA |
| Ultimate breaking capacity (Icu) at 500 V AC | 50 kA |
| Ultimate breaking capacity (Icu) at 525 V AC | 30 kA |
| Ultimate breaking capacity (Icu) at 690 V AC | 15 kA |
| Service breaking capacity (Ics) at 415 V AC | 70 kA |
| Mounting / execution | Fixed |
| Terminal position | Front |
| Main circuit connection | Bolt connection |
| Operating element | Toggle / handle |
| Reference standard | IEC 60947-2 |
| Power loss per pole at rated operating conditions | 0.1 W |
| EAN / GTIN | 8056221001243 |
The ABB 1SDA100070R1 is a 10 A three-pole moulded case circuit breaker designed to provide overload, instantaneous short-circuit and ground-fault protection in demanding low-voltage AC distribution systems.
The Ekip Dip LIG electronic trip unit provides long-time (L), instantaneous (I) and ground-fault (G) protection functions.
The instantaneous short-circuit protection can be adjusted from 10–100 A, corresponding to a range of 1–10 times the 10 A rated trip current.
The XT2H performance level provides both an ultimate short-circuit breaking capacity Icu and service breaking capacity Ics of 70 kA at 415 V AC.
The 1SDA100070R1 is supplied as a fixed three-pole circuit breaker with front terminals for integration into compatible low-voltage switchboards, distribution panels and electrical assemblies.
ABB SACE Tmax XT moulded case circuit breakers combine compact construction, configurable electronic protection and robust short-circuit performance, with the XT2H Ekip Dip LIG platform providing high interruption capability plus overload, instantaneous and ground-fault protection for demanding low-voltage distribution systems.