1SDA100056R1 ABB XT2S 160 Ekip Dip LIG 25 A 4-Pole Circuit Breaker

1SDA100056R1 ABB XT2S 160 Ekip Dip LIG 25 A 4-Pole Circuit Breaker

ABB 1SDA100056R1 is an XT2S 160 four-pole fixed moulded case circuit breaker with a 25 A Ekip Dip LIG electronic trip unit and 50 kA breaking capacity at 415 V AC for reliable low-voltage circuit protection.

SKU: 1SDA100056R1MPN: 1SDA100056R1
Price
List Price £2,026.52 ex VAT
Your Price (ex VAT) Save 25%
£1,519.89 25% OFF
You save £506.63 per unit
Manufacturer Lead Time Estimated Delivery 5 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £1,519.89
Trade pricing is personalised to your account

Manufacturer Lead Time

£1,519.89

Why Choose the ABB 1SDA100056R1 XT2S 160 Ekip Dip LIG Circuit Breaker?

The ABB 1SDA100056R1 is a high-performance four-pole moulded case circuit breaker (MCCB) designed for reliable protection of low-voltage AC electrical distribution systems. Part of the advanced ABB SACE Tmax XT range, this XT2S 160 circuit breaker combines compact construction, high short-circuit performance and electronic protection for demanding industrial and commercial installations.

This circuit breaker is equipped with an Ekip Dip LIG electronic trip unit, providing long-time, instantaneous and ground-fault protection functions. The solid-state release provides accurate protection for electrical circuits while the four-pole configuration enables switching and protection across three phases and neutral in suitable distribution systems.

With a rated trip current of 25 A, a 160 A XT2 frame and a rated operational voltage of up to 690 V AC, the 1SDA100056R1 is suitable for installation, transformer and generator protection applications. The XT2S performance level provides an ultimate short-circuit breaking capacity of 50 kA at 415 V AC, while its fixed construction and front terminals support straightforward switchboard installation.

Key Advantages

  • Compact ABB SACE Tmax XT moulded case circuit breaker for low-voltage distribution.
  • 25 A Ekip Dip LIG electronic trip unit for accurate circuit protection.
  • Four-pole fixed configuration suitable for three-phase and neutral distribution systems.
  • 50 kA ultimate breaking capacity at 415 V AC for robust short-circuit protection.
  • Long-time, instantaneous and ground-fault protection functions.
  • 690 V AC rated operational voltage supports demanding industrial applications.
  • Front-terminal arrangement simplifies installation within electrical switchboards.

Key Features

  • ABB SACE Tmax XT series.
  • XT2S 160 frame.
  • 25 A rated trip current.
  • Ekip Dip LIG electronic trip unit.
  • Four-pole configuration.
  • Fixed circuit breaker construction.
  • Front terminals for main circuit connections.
  • 50 kA breaking capacity at 415 V AC.
  • 8 kV rated impulse withstand voltage.
  • Electronic long-time, instantaneous and ground-fault protection.

Reliable Electronic Protection for Power Distribution

Moulded case circuit breakers such as the ABB Tmax XT2 protect electrical installations against damaging overcurrents and short circuits while providing dependable circuit switching and isolation. The electronic Ekip Dip trip technology enables accurate protection characteristics for modern industrial and commercial low-voltage distribution systems.

The Ekip Dip LIG release combines long-time protection against sustained overloads, instantaneous protection against severe short-circuit currents and ground-fault protection. Together with the XT2S breaker’s high interruption capability, four-pole construction and compact dimensions, these functions make the 1SDA100056R1 particularly suitable for demanding distribution boards and industrial electrical installations.

Typical Applications

  • Industrial low-voltage distribution boards.
  • Commercial electrical switchboards.
  • Transformer protection systems.
  • Generator protection and distribution circuits.
  • Three-phase and neutral electrical distribution systems.
  • Manufacturing and process-industry electrical installations.

Technical Specifications

Series SACE Tmax XT
Product group T-Max XT 250 Range
Order code 1SDA100056R1
EAN / GTIN 8056221001106
Product type Moulded case circuit breaker (MCCB)
Frame XT2 160
Short-circuit performance level S
Rated current 25 A
Rated uninterrupted current 160 A
Rated operational voltage 690 V AC
Rated insulation voltage 1000 V
Rated impulse withstand voltage 8 kV
Number of poles 4
Trip unit Ekip Dip LIG electronic release
Protection functions Long-time, instantaneous and ground fault
Ultimate breaking capacity at 220–240 V AC 85 kA
Ultimate breaking capacity at 380–440 V AC 50 kA
Ultimate breaking capacity at 500 V AC 36 kA
Ultimate breaking capacity at 525 V AC 25 kA
Ultimate breaking capacity at 690 V AC 12 kA
Standard IEC 60947-2
Installation Fixed
Terminal type Front terminals
Dimensions (H × W × D) 130 × 120 × 82.5 mm
Net weight approx. 1.5 kg

Frequently Asked Questions

What is the ABB 1SDA100056R1 used for?

The ABB 1SDA100056R1 is a four-pole moulded case circuit breaker designed to protect low-voltage AC electrical distribution circuits against overloads, short circuits and ground faults.

What is the rated current of the ABB 1SDA100056R1?

The circuit breaker is fitted with an Ekip Dip LIG electronic trip unit rated at 25 A and uses the ABB XT2 160 frame.

What protection functions does the Ekip Dip LIG trip unit provide?

The Ekip Dip LIG electronic trip unit provides long-time, instantaneous and ground-fault protection for reliable protection of low-voltage electrical circuits.

What is the breaking capacity of the ABB XT2S 160?

The XT2S performance level provides an ultimate short-circuit breaking capacity of 50 kA at 415 V AC, with breaking performance dependent on the system voltage.

How is the ABB 1SDA100056R1 installed?

The 1SDA100056R1 is a fixed four-pole circuit breaker with front terminals, making it suitable for installation in electrical switchboards and industrial distribution panels.

Trusted Protection from ABB

ABB SACE Tmax XT moulded case circuit breakers provide compact and reliable protection for industrial and commercial low-voltage distribution systems, combining robust interruption performance with advanced electronic protection technology.