1SDA100046R1 ABB XT2S 160 Ekip Dip LSI In=25A 4P Moulded Case Circuit Breaker

1SDA100046R1 ABB XT2S 160 Ekip Dip LSI In=25A 4P Moulded Case Circuit Breaker

ABB 1SDA100046R1 is an XT2S 160 four-pole fixed moulded case circuit breaker with front terminals and a 25 A Ekip Dip electronic trip unit providing LSI overload and short-circuit protection.

SKU: 1SDA100046R1MPN: 1SDA100046R1
Price
List Price £1,692.95 ex VAT
Your Price (ex VAT) Save 25%
£1,269.71 25% OFF
You save £423.24 per unit
Manufacturer Lead Time Estimated Delivery 4 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £1,269.71
Trade pricing is personalised to your account

Manufacturer Lead Time

£1,269.71

Why Choose the ABB XT2S 160 Ekip Dip LSI In=25A 4P Circuit Breaker?

The ABB XT2S 160 Ekip Dip LSI In=25A 4P, order code 1SDA100046R1, is a compact moulded case circuit breaker (MCCB) from the ABB SACE Tmax XT range. It combines the XT2S 160 frame with a 25 A Ekip Dip electronic trip unit for advanced protection of low-voltage industrial, commercial and OEM electrical distribution systems.

The Ekip Dip LSI trip unit provides long-time (L), short-time (S) and instantaneous (I) protection. These electronic protection functions provide coordinated response to sustained overloads, short-circuit conditions requiring time-selective operation and severe faults requiring rapid instantaneous interruption.

The 1SDA100046R1 is supplied as a four-pole fixed circuit breaker with front terminals. Its XT2S performance level provides substantial short-circuit interruption capability, while the four-pole configuration makes it suitable for distribution systems requiring simultaneous switching and protection across all four poles.

Key Advantages

  • Compact ABB SACE Tmax XT2 moulded case circuit breaker.
  • 25 A Ekip Dip electronic trip unit for precise circuit protection.
  • LSI protection functions cover overload, short-time and instantaneous short-circuit conditions.
  • S short-circuit performance level for demanding distribution applications.
  • Four-pole configuration for systems requiring four-pole switching and protection.
  • Electronic protection supports effective selectivity and coordination within electrical distribution systems.
  • Fixed execution with front terminals for straightforward switchboard integration.

Key Features

  • ABB SACE Tmax XT2S 160 platform.
  • 160 A frame size.
  • 25 A rated trip-unit current.
  • Ekip Dip electronic trip unit.
  • LSI electronic protection.
  • L – Long-time overload protection.
  • S – Short-time short-circuit protection.
  • I – Instantaneous short-circuit protection.
  • S short-circuit performance level.
  • 4-pole configuration.
  • Fixed mounting with front terminals.

Advanced LSI Electronic Circuit Protection

The ABB Ekip Dip LSI trip unit combines three complementary protection functions. Long-time protection responds to sustained overloads, short-time protection allows controlled response to short-circuit currents for improved selectivity with other protective devices, and instantaneous protection provides rapid interruption when severe fault currents occur.

By combining these electronic protection functions with the compact XT2S frame, the ABB 1SDA100046R1 provides a flexible solution for sophisticated low-voltage distribution systems. Its 25 A trip-unit rating, four-pole construction and fixed front-terminal arrangement make it particularly suitable for low-current feeders and circuits where coordinated electronic protection is required.

Typical Applications

  • Industrial low-voltage distribution boards.
  • Commercial building power distribution.
  • Four-pole feeder and branch-circuit protection.
  • Switchboards requiring electronic protection and selectivity.
  • Industrial machinery and control panels.
  • OEM electrical distribution assemblies.
  • Circuits requiring LSI overload and short-circuit protection.

Technical Specifications

Series SACE Tmax XT
ABB order code 1SDA100046R1
Product type Moulded case circuit breaker
Frame XT2S
Frame size 160 A
Rated trip-unit current (In) 25 A
Trip unit Ekip Dip electronic
Protection functions LSI
Long-time protection L
Short-time protection S
Instantaneous protection I
Short-circuit performance level S
Number of poles 4
Mounting execution Fixed
Terminal arrangement Front terminals

Frequently Asked Questions

What is the ABB 1SDA100046R1?

The ABB 1SDA100046R1 is an XT2S 160 four-pole fixed moulded case circuit breaker with front terminals and a 25 A Ekip Dip LSI electronic trip unit.

What is the trip-unit current rating of the ABB 1SDA100046R1?

The Ekip Dip electronic trip unit has a rated current of 25 A and is installed in the XT2S 160 frame.

What does LSI mean on the ABB Ekip Dip trip unit?

LSI represents long-time, short-time and instantaneous protection, providing electronic protection against overloads and different levels of short-circuit fault current.

Does the ABB 1SDA100046R1 provide earth-fault protection?

This specific trip unit is an LSI configuration, so its stated protection functions are long-time, short-time and instantaneous protection; a G earth-fault function is not included in the LSI designation.

What frame does the ABB 1SDA100046R1 use?

The circuit breaker uses the ABB XT2S 160 frame and is equipped with a 25 A Ekip Dip electronic trip unit.

How many poles does the ABB 1SDA100046R1 have?

The breaker has four poles, making it suitable for systems requiring simultaneous four-pole switching and circuit protection.

How is the ABB XT2S 160 1SDA100046R1 installed?

This model is supplied in a fixed configuration with front terminals for permanent integration into compatible switchboards, distribution panels and industrial electrical assemblies.

Trusted by Electrical Professionals Worldwide

ABB SACE Tmax XT moulded case circuit breakers are used by panel builders, electrical engineers, machine builders and OEMs for dependable electronic overload and short-circuit protection in commercial and industrial low-voltage distribution systems.