1SDA100041R1 ABB XT2S 160 Ekip Dip LIG 25 A 3-Pole Circuit Breaker

1SDA100041R1 ABB XT2S 160 Ekip Dip LIG 25 A 3-Pole Circuit Breaker

ABB 1SDA100041R1 XT2S 160 is a 25 A three-pole fixed moulded case circuit breaker with front terminals, an Ekip Dip LIG electronic trip unit and 50 kA ultimate breaking capacity at 400–415 V AC.

SKU: 1SDA100041R1MPN: 1SDA100041R1
Price
List Price £1,592.78 ex VAT
Your Price (ex VAT) Save 25%
£1,194.59 25% OFF
You save £398.20 per unit
Manufacturer Lead Time Estimated Delivery 5 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £1,194.59
Trade pricing is personalised to your account

Manufacturer Lead Time

£1,194.59

Why Choose the ABB XT2S 160 Ekip Dip LIG In=25A 3p F F Circuit Breaker?

The ABB 1SDA100041R1 is a compact three-pole moulded case circuit breaker (MCCB) from the ABB SACE Tmax XT2 range, designed for dependable protection of transformers, generators and low-voltage electrical installations. Rated at 25 A, it combines the XT2S 160 frame with an Ekip Dip LIG electronic trip unit for configurable overload, instantaneous short-circuit and ground-fault protection functions.

The Ekip Dip LIG release provides long-time (L), instantaneous (I) and ground-fault (G) protection functionality. Its electronic protection architecture allows the breaker to respond effectively to sustained overloads and severe short-circuit conditions, while the ground-fault function supports coordinated protection strategies within suitable electrical distribution systems.

The 1SDA100041R1 is supplied as a fixed three-pole breaker with front terminals and is rated for operation at up to 690 V AC. The XT2S performance level provides an ultimate short-circuit breaking capacity of 50 kA at 400–415 V AC, making this MCCB suitable for industrial, commercial and infrastructure distribution systems where compact dimensions and substantial fault interruption capability are required.

Key Advantages

  • 25 A electronic MCCB for transformer, generator and installation protection.
  • Ekip Dip LIG electronic trip unit provides long-time, instantaneous and ground-fault protection functions.
  • Instantaneous short-circuit protection adjustable from 25–250 A.
  • High 50 kA ultimate breaking capacity at 400–415 V AC.
  • Compact XT2S 160 construction helps optimise switchboard space.
  • Fixed three-pole configuration with convenient front terminals.

Key Features

  • ABB SACE Tmax XT2S 160 moulded case circuit breaker.
  • 25 A rated current.
  • Three-pole configuration.
  • Ekip Dip LIG electronic release.
  • Long-time (L) overload protection.
  • Instantaneous (I) short-circuit protection.
  • Ground-fault (G) protection function.
  • S performance level with high short-circuit interruption capability.
  • Rated voltage of 690 V AC.
  • Fixed execution with front terminals.

Electronic LIG Protection with High Breaking Capacity

The ABB Ekip Dip LIG trip unit combines multiple electronic protection functions within the compact Tmax XT2 platform. Long-time protection responds to sustained overload conditions, instantaneous protection rapidly disconnects severe short circuits, and the ground-fault function supports protection strategies addressing current flowing towards earth. This combination provides flexible protection for a wide range of low-voltage distribution applications.

The XT2S performance level combines the compact XT2 frame with substantial short-circuit interruption capability. With a 50 kA Icu at 400–415 V AC, a 25 A Ekip Dip LIG release and fixed front-terminal construction, the 1SDA100041R1 is well suited to distribution panels where low-current electronic protection must operate reliably in systems with comparatively high prospective fault currents.

Typical Applications

  • Transformer protection.
  • Generator protection.
  • Industrial low-voltage power distribution.
  • Commercial building electrical distribution.
  • Switchboards and distribution panels requiring electronic protection.
  • OEM machinery and electrical distribution assemblies.

Technical Specifications

Series SACE Tmax XT / T-Max XT 250 Range
ABB order code 1SDA100041R1
Product type Moulded case circuit breaker
Frame XT2S 160
Frame size XT2
Rated current (In) 25 A
Trip unit Ekip Dip LIG electronic release
Protection functions Long-time (L), instantaneous (I) and ground-fault (G)
Instantaneous short-circuit protection adjustment 25–250 A
Number of poles 3
Rated voltage 690 V AC
Ultimate breaking capacity (Icu) at 400–415 V AC 50 kA
Mounting / execution Fixed
Terminal position Front
Main circuit connection Bolt connection
Operating element Toggle
Complete device with protection unit Yes
Integrated motor operator No
Optional motor operator Yes
Degree of protection IP20
Power loss 0.8 W
EAN / GTIN 8056221000956
Customs tariff number 85362090

Frequently Asked Questions

What is the ABB 1SDA100041R1 used for?

The ABB 1SDA100041R1 is a 25 A three-pole moulded case circuit breaker designed for transformer, generator and installation protection in low-voltage AC distribution systems.

What protection functions does the Ekip Dip LIG trip unit provide?

The Ekip Dip LIG electronic trip unit provides long-time (L), instantaneous (I) and ground-fault (G) protection functions.

What is the rated current of the ABB XT2S 160 1SDA100041R1?

The circuit breaker has a rated current of 25 A and uses the compact ABB SACE Tmax XT2S 160 frame.

What is the breaking capacity of the ABB XT2S 160 1SDA100041R1?

The XT2S performance level provides an ultimate short-circuit breaking capacity of 50 kA at 400–415 V AC.

How is the ABB 1SDA100041R1 installed?

The 1SDA100041R1 is supplied as a fixed three-pole circuit breaker with front terminals for integration into compatible low-voltage switchboards, distribution panels and electrical assemblies.

Trusted ABB Electronic Circuit Protection for Power Distribution

ABB SACE Tmax XT moulded case circuit breakers combine compact construction, configurable electronic protection and robust short-circuit performance, with the XT2S platform providing dependable protection for transformers, generators and industrial or commercial low-voltage distribution systems.