Why Choose the ABB XT2N 160 Ekip Dip LIG In=100A 3p F F?

The ABB 1SDA100013R1 XT2N 160 Ekip Dip LIG In=100A 3p F F is a high-performance moulded case circuit breaker (MCCB) designed for reliable protection and control of low voltage electrical distribution systems. Part of the advanced ABB SACE Tmax XT2 range, this fixed three-pole circuit breaker combines compact construction with an electronic Ekip Dip LIG trip unit for accurate protection of industrial and commercial power installations.

The XT2N 160 provides dependable overcurrent protection through its integrated Ekip Dip LIG solid-state release, offering long-time, instantaneous and ground fault protection functions. Its fixed front terminal design enables straightforward installation in switchboards, distribution panels and industrial electrical assemblies.

With a 100 A rated current, 160 A frame size, and a three-pole configuration, the ABB XT2N 160 Ekip Dip LIG is suitable for demanding AC distribution applications requiring reliable circuit interruption and advanced protection performance. :chatgpt-content-reference{index="0"}

Key Advantages

  • ABB SACE Tmax XT2 moulded case circuit breaker designed for low voltage power distribution.
  • 100 A rated current suitable for a wide range of industrial applications.
  • Integrated Ekip Dip LIG electronic trip unit for accurate circuit protection.
  • Three-pole fixed front terminal configuration for simple switchboard installation.
  • High short-circuit breaking capability for demanding electrical networks.
  • Compact XT2 frame design reduces panel space requirements while maintaining performance.

Key Features

  • ABB SACE Tmax XT2 series.
  • XT2N 160 frame size.
  • 100 A rated uninterrupted current.
  • 3-pole AC moulded case circuit breaker.
  • Ekip Dip LIG electronic release.
  • Fixed version with front terminals.
  • Rated operational voltage up to 690 V AC.
  • Rated insulation voltage 1000 V.
  • Rated impulse withstand voltage 8 kV.
  • Compatible with ABB Tmax XT accessory systems.

Reliable Protection for Low Voltage Distribution

Moulded case circuit breakers such as the ABB Tmax XT2 provide essential protection against overloads and short circuits while enabling safe isolation and reliable operation of electrical systems. The integrated Ekip Dip electronic release continuously monitors circuit conditions and provides accurate protective tripping when required.

The Tmax XT range is developed for modern electrical distribution applications, combining compact dimensions, advanced protection technology and flexible accessories. The XT2N 160 Ekip Dip LIG is suited to engineers requiring dependable circuit protection in industrial, commercial and infrastructure installations. :chatgpt-content-reference{index="1"}

Typical Applications

  • Industrial power distribution boards.
  • Commercial electrical switchboards.
  • Motor control centres.
  • Machine and automation panels.
  • Building electrical infrastructure.
  • OEM equipment requiring reliable circuit protection.

Technical Specifications

Product code 1SDA100013R1
Series SACE Tmax XT
Product type Moulded case circuit breaker
Frame size XT2 160
Number of poles 3P
Rated current (In) 100 A
Rated uninterrupted current (Iu) 160 A
Release type Ekip Dip LIG electronic release
Rated operational voltage 690 V AC
Rated insulation voltage (Ui) 1000 V
Rated impulse withstand voltage (Uimp) 8 kV
Short-circuit performance level N
Rated service short-circuit breaking capacity (Ics) up to 65 kA
Rated ultimate short-circuit breaking capacity (Icu) up to 65 kA
Standards IEC 60947-2
Terminal connection type Front terminals
Version Fixed (F)
Dimensions (H × W × D) approx. 130 × 90 × 82.5 mm
Weight approx. 1.12 kg

Frequently Asked Questions

What is the ABB 1SDA100013R1 used for?

The ABB 1SDA100013R1 is a Tmax XT2 moulded case circuit breaker designed for protecting and controlling low voltage AC electrical distribution systems.

What is the rated current of this circuit breaker?

The XT2N 160 Ekip Dip LIG has a rated current of 100 A.

How many poles does the ABB XT2N 160 have?

This circuit breaker has a three-pole (3P) configuration.

Which trip unit is fitted to this breaker?

The circuit breaker is fitted with an Ekip Dip LIG electronic release providing advanced protection functions.

What voltage rating does the XT2N 160 support?

The breaker has a rated operational voltage of up to 690 V AC.

Trusted by Electrical Engineers Worldwide

ABB Tmax XT circuit breakers deliver reliable protection, compact installation and advanced electronic monitoring for modern low voltage electrical distribution systems.