1SDA100012R1 ABB XT2N 160 Ekip Dip LIG 63A 3P F F Circuit Breaker

1SDA100012R1 ABB XT2N 160 Ekip Dip LIG 63A 3P F F Circuit Breaker

ABB 1SDA100012R1 is a 63 A three-pole SACE Tmax XT2N 160 moulded case circuit breaker with Ekip Dip LIG electronic overload, instantaneous short-circuit and ground-fault protection, fixed mounting, front terminals and 36 kA Icu/Ics at 415 V AC.

SKU: 1SDA100012R1MPN: 1SDA100012R1
Price
List Price £1,551.02 ex VAT
Your Price (ex VAT) Save 25%
£1,163.27 25% OFF
You save £387.76 per unit
Manufacturer Lead Time Estimated Delivery 5 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £1,163.27
Trade pricing is personalised to your account

Manufacturer Lead Time

£1,163.27

Why Choose the ABB XT2N 160 Ekip Dip LIG 63A 3P Circuit Breaker?

The ABB XT2N 160 Ekip Dip LIG In=63A 3P F F, order code 1SDA100012R1, is a three-pole moulded case circuit breaker (MCCB) from the ABB SACE Tmax XT range. Built on the compact XT2 160 A frame, it combines electronic protection with the XT2N short-circuit performance level for industrial and commercial low-voltage power distribution.

This circuit breaker has a 63 A rated current and incorporates an Ekip Dip LIG solid-state electronic trip unit. Its protection functions include long-time overload (L), instantaneous short-circuit (I) and ground-fault protection (G), with adjustable thresholds for effective coordination with the protected circuit.

The 1SDA100012R1 is supplied as a fixed three-pole circuit breaker with front terminals. It has a rated operational voltage of up to 690 V AC and provides both ultimate and service short-circuit breaking capacities of 36 kA at 415 V AC, making it suitable for distribution, transformer, generator and installation protection.

Key Advantages

  • 63 A three-pole MCCB from the ABB SACE Tmax XT range.
  • Compact XT2 160 A frame for space-efficient panel integration.
  • Ekip Dip LIG electronic trip unit provides configurable protection.
  • Long-time (L) protection for sustained overload conditions.
  • Instantaneous (I) protection for high short-circuit currents.
  • Ground-fault (G) protection for earth-fault conditions.
  • Icu and Ics of 36 kA at 415 V AC for dependable fault interruption.
  • Fixed mounting with front terminals for practical switchboard installation.

Key Features

  • ABB SACE Tmax XT series.
  • XT2 frame size.
  • N short-circuit performance level.
  • 160 A rated uninterrupted current.
  • 63 A rated current.
  • Ekip Dip LIG electronic release.
  • L, I and G protection functions.
  • Long-time protection threshold adjustable from 0.4–1 × In.
  • Instantaneous protection threshold adjustable from 1–10 × In, with OFF setting.
  • Ground-fault protection threshold adjustable from 0.2–1 × In, with OFF setting.
  • Three-pole configuration.
  • Fixed installation with front terminals.
  • Rated operational voltage up to 690 V AC.

Configurable Electronic LIG Protection for Critical Circuits

The Ekip Dip LIG release provides three complementary protection functions. Long-time protection responds to sustained overloads, instantaneous protection provides rapid operation during severe short circuits, and the ground-fault function detects earth-fault currents that require dedicated protection.

The adjustable thresholds allow the 1SDA100012R1 to be coordinated with the characteristics of the protected installation. Combined with the XT2N platform, which provides Icu and Ics ratings of 36 kA at 415 V AC, the breaker offers a compact electronic protection solution for demanding low-voltage distribution systems.

Typical Applications

  • Industrial low-voltage distribution boards.
  • Commercial electrical distribution systems.
  • Feeder and cable protection.
  • Transformer protection.
  • Generator protection circuits.
  • Electrical switchboards and panel assemblies.
  • Industrial machinery and process installations.
  • OEM switchgear and electrical equipment.

Technical Specifications

Series SACE Tmax XT
Product family T-Max XT 250 Range
ABB order code 1SDA100012R1
EAN 8056221000673
Product type Moulded case circuit breaker (MCCB)
Frame XT2
Rated uninterrupted current (Iu) 160 A
Short-circuit performance level N / 36 kA
Rated current (In) 63 A
Trip unit Ekip Dip LIG solid-state electronic release
Protection functions Long-time overload, instantaneous short circuit and ground fault (LIG)
Long-time protection threshold 0.4–1 × In in 0.04 steps
Instantaneous protection threshold OFF / 1–10 × In
Ground-fault protection threshold OFF / 0.2–1 × In
Number of poles 3
Installation Fixed
Terminal configuration Front terminals
Rated operational voltage 690 V AC
Rated insulation voltage (Ui) 1000 V
Rated impulse withstand voltage (Uimp) 8 kV
Ultimate short-circuit breaking capacity (Icu) at 415 V AC 36 kA
Service short-circuit breaking capacity (Ics) at 415 V AC 36 kA
Product net width 90 mm
Product net height 130 mm
Product net depth 82.5 mm
Product net weight 1.12 kg
Standard IEC 60947

Frequently Asked Questions

What is the ABB 1SDA100012R1?

The ABB 1SDA100012R1 is an XT2N 160 three-pole moulded case circuit breaker with a 63 A rated current, Ekip Dip LIG electronic protection, fixed mounting and front terminals.

What protection functions does the Ekip Dip LIG release provide?

The Ekip Dip LIG release provides long-time overload protection (L), instantaneous short-circuit protection (I) and ground-fault protection (G).

What are the adjustable protection thresholds on the ABB 1SDA100012R1?

Long-time protection is adjustable from 0.4–1 × In, instantaneous protection from 1–10 × In with an OFF setting, and ground-fault protection from 0.2–1 × In with an OFF setting.

What is the breaking capacity of the ABB XT2N 1SDA100012R1?

At 415 V AC, the XT2N version provides both an ultimate short-circuit breaking capacity (Icu) and service short-circuit breaking capacity (Ics) of 36 kA.