1SDA080837R1 ABB XT1H 160 TMD 25-450 3P F F Circuit Breaker

1SDA080837R1 ABB XT1H 160 TMD 25-450 3P F F Circuit Breaker

ABB 1SDA080837R1 is a 25 A three-pole SACE Tmax XT1H 160 moulded case circuit breaker with TMD thermomagnetic protection, fixed mounting, front terminals and 70 kA ultimate breaking capacity at 415 V AC.

SKU: 1SDA080837R1Alt SKU: XT1H 160MPN: 1SDA080837R1
Price
List Price £396.43 ex VAT
Your Price (ex VAT) Save 25%
£297.32 25% OFF
You save £99.11 per unit
Manufacturer Lead Time Estimated Delivery 5 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £297.32
Trade pricing is personalised to your account

Manufacturer Lead Time

£297.32

Why Choose the ABB XT1H 160 TMD 25-450 3P Circuit Breaker?

The ABB XT1H 160 TMD 25-450 3P F F, order code 1SDA080837R1, is a three-pole moulded case circuit breaker (MCCB) from the ABB SACE Tmax XT range. Built on the compact XT1 160 A frame, it combines high breaking performance with thermomagnetic protection for low-voltage power-distribution applications.

This XT1H breaker has a 25 A rated current and uses an ABB TMD thermomagnetic trip unit providing overload and short-circuit protection. The product designation specifies a 25–450 A protection range, while the H performance class provides a high short-circuit breaking capability, including 70 kA Icu at 415 V AC.

The 1SDA080837R1 is supplied as a fixed three-pole circuit breaker with front terminals. With a rated operational voltage up to 690 V AC, it is suitable for industrial switchboards, commercial distribution systems, machinery panels and other installations requiring compact and dependable circuit protection.

Key Advantages

  • 25 A three-pole MCCB from the ABB SACE Tmax XT family.
  • XT1H high-breaking-capacity version for demanding distribution applications.
  • TMD thermomagnetic trip unit provides overload and short-circuit protection.
  • 70 kA Icu at 415 V AC for high fault-current capability.
  • Compact XT1 160 A frame supports space-efficient panel design.
  • Fixed installation for straightforward switchboard integration.
  • Front terminals provide practical conductor access during installation.
  • Rated operational voltage up to 690 V AC.

Key Features

  • ABB SACE Tmax XT series.
  • XT1 frame size.
  • H breaking-capacity class.
  • 160 A frame rating.
  • 25 A rated current.
  • TMD thermomagnetic release.
  • 25–450 A product protection range.
  • Three-pole configuration.
  • Fixed mounting.
  • Front terminals.
  • Rated operational voltage up to 690 V AC.
  • Designed for IEC low-voltage distribution applications.

High-Performance Thermomagnetic Circuit Protection

The ABB TMD release combines thermal overload protection with magnetic short-circuit protection. The thermal function responds to sustained overcurrent conditions that could damage cables and connected equipment, while the magnetic function provides rapid operation when a high short-circuit current occurs.

Combined with the XT1H high-breaking-capacity platform, this protection system makes the 1SDA080837R1 suitable for circuits where dependable fault interruption and compact dimensions are important. Its fixed construction and front terminals also simplify integration into compatible low-voltage switchboards and distribution assemblies.

Typical Applications

  • Industrial low-voltage distribution boards.
  • Commercial electrical distribution systems.
  • Feeder and cable protection.
  • Electrical switchboards and panel assemblies.
  • Industrial machinery power circuits.
  • Manufacturing and process equipment.
  • Building electrical distribution systems.
  • OEM low-voltage electrical equipment.

Technical Specifications

Series SACE Tmax XT
ABB order code 1SDA080837R1
Alternate catalogue number XT1HE3025AFF000XXX
Product type Moulded case circuit breaker (MCCB)
Frame XT1
Frame rating 160 A
Breaking-capacity class H
Rated current (In) 25 A
Trip unit TMD thermomagnetic
Protection Overload and short circuit
Product protection range 25–450 A
Number of poles 3
Installation Fixed
Terminal configuration Front terminals
Rated operational voltage Up to 690 V AC
Rated insulation voltage (Ui) 800 V
Rated impulse withstand voltage (Uimp) 8 kV
Ultimate short-circuit breaking capacity (Icu) at 415 V AC 70 kA
Standards IEC
EAN/UPC 8015644873653

Frequently Asked Questions

What is the ABB 1SDA080837R1?

The ABB 1SDA080837R1 is an XT1H 160 three-pole moulded case circuit breaker with a 25 A rated current, TMD thermomagnetic protection, fixed mounting and front terminals.

What is the rated current of the ABB XT1H 1SDA080837R1?

The circuit breaker has a rated current of 25 A and uses the ABB XT1 frame, which has a 160 A frame rating.

What protection does the TMD trip unit provide?

The TMD thermomagnetic trip unit provides thermal overload protection and magnetic short-circuit protection for the connected circuit.

What is the breaking capacity of the ABB XT1H 160?

The H-performance XT1 version provides an ultimate short-circuit breaking capacity of 70 kA at 415 V AC.

How is the ABB 1SDA080837R1 installed?

The 1SDA080837R1 is a fixed three-pole circuit breaker with front terminals, making it suitable for integration into compatible switchboards, distribution panels and electrical assemblies.

Trusted by Electrical Professionals Worldwide

ABB SACE Tmax XT moulded case circuit breakers combine compact construction, dependable circuit protection and high short-circuit performance for industrial and commercial low-voltage distribution systems.