ABB 1SDA075197R1 XT4S 250 is a three-pole fixed UL/CSA moulded case circuit breaker with front terminals, a 100 A TMA thermomagnetic release, 70–100 A adjustable overload protection and 500–1000 A adjustable instantaneous short-circuit protection.

SKU: 1SDA075197R1MPN: 1SDA075197R1
Price
List Price £697.03 ex VAT
Your Price (ex VAT) Save 25%
£522.77 25% OFF
You save £174.26 per unit
Manufacturer Lead Time Estimated Delivery 5 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £522.77
Trade pricing is personalised to your account

Manufacturer Lead Time

£522.77

Why Choose the ABB XT4S 250 TMA 100 500..1000 3p F F UL/CSA Circuit Breaker?

The ABB XT4S 250 TMA 100 500..1000 3p F F UL/CSA, order code 1SDA075197R1, is a three-pole moulded case circuit breaker designed for dependable overload and short-circuit protection in low-voltage electrical distribution systems. Part of the ABB SACE Tmax XT / T-Max XT 250 Range, it combines the compact XT4 frame with an adjustable thermomagnetic release for industrial and commercial power distribution applications.

The breaker incorporates an ABB TMA thermomagnetic release with a nominal setting of 100 A. Its overload protection is adjustable from 70–100 A, while the instantaneous magnetic short-circuit release can be adjusted from 500–1000 A, allowing protection settings to be matched to the requirements of the connected circuit.

This XT4S configuration features a three-pole fixed construction with front terminals and is designed for operation on systems up to 600 V AC. The S-performance XT4 provides a short-circuit breaking capacity of 35 kA, making the 1SDA075197R1 a practical UL/CSA solution for switchboards, distribution panels, machinery and other demanding electrical installations.

Key Advantages

  • Compact ABB SACE Tmax XT4 moulded case circuit breaker.
  • 100 A TMA thermomagnetic release with adjustable overload protection.
  • 70–100 A overload adjustment range for application flexibility.
  • 500–1000 A adjustable instantaneous magnetic trip for short-circuit protection.
  • S-class 35 kA short-circuit breaking capacity.
  • Three-pole fixed construction with front terminals for straightforward panel integration.

Key Features

  • ABB SACE Tmax XT4S 250 frame.
  • TMA adjustable thermomagnetic trip unit.
  • 100 A nominal trip-unit rating.
  • 70–100 A adjustable thermal overload setting.
  • 500–1000 A adjustable instantaneous magnetic setting.
  • Three-pole construction.
  • Up to 600 V AC rated voltage.
  • 35 kA S-performance short-circuit breaking capacity.
  • Fixed mounting with front terminals.
  • UL/CSA configuration for North American electrical distribution applications.

Adjustable Thermomagnetic Circuit Protection

The TMA thermomagnetic release provides adjustable protection against both overload and short-circuit conditions. Its thermal element can be set between 70 and 100 A, allowing the breaker to be coordinated with the protected conductors and load, while the magnetic element provides rapid fault interruption with an adjustable 500–1000 A instantaneous trip range.

The ABB Tmax XT4 platform combines compact dimensions with flexible protection and installation options. The fixed three-pole construction and front-terminal arrangement of the 1SDA075197R1 make it suitable for integration into switchboards, distribution assemblies, machinery panels and other low-voltage installations.

Typical Applications

  • Industrial low-voltage distribution boards.
  • Commercial electrical switchboards.
  • UL/CSA power distribution assemblies.
  • Feeder and distribution circuit protection.
  • Transformer and generator protection circuits.
  • Industrial machinery and OEM electrical panels.

Technical Specifications

Series SACE Tmax XT / T-Max XT 250 Range
ABB order code 1SDA075197R1
Extended product type XT4S 250 TMA 100 500..1000 3p F F UL/CSA
Product type Moulded case circuit breaker
Frame size XT4
Frame designation XT4S 250
Performance level S
Trip unit TMA thermomagnetic
Trip-unit rating 100 A
Overload release adjustment 70–100 A
Instantaneous short-circuit release adjustment 500–1000 A
Number of poles 3
Rated voltage up to 600 V AC
Short-circuit breaking capacity 35 kA
Mounting type Fixed
Terminal type Front terminals
Main-circuit connection Bolt connection
Degree of protection IP20
Certification UL / CSA
EAN 8015644791742

Frequently Asked Questions

What is the ABB 1SDA075197R1 used for?

It is a three-pole moulded case circuit breaker designed to provide adjustable overload and short-circuit protection in low-voltage electrical distribution systems.

What is the current rating of the ABB XT4S 250 TMA 1SDA075197R1?

The TMA thermomagnetic release has a nominal rating of 100 A, with its overload protection adjustable from 70–100 A.

What does 500..1000 mean in the model designation?

It identifies the adjustable instantaneous magnetic short-circuit trip range of 500–1000 A.

What is the short-circuit breaking capacity of the XT4S?

The XT4S is the S-performance version of the Tmax XT4 and provides a short-circuit breaking capacity of 35 kA.

How is the ABB XT4S 1SDA075197R1 installed?

This model is a fixed three-pole circuit breaker with front terminals, designed for installation in compatible switchboards, distribution panels and industrial electrical assemblies.

Trusted ABB Circuit Protection

ABB SACE Tmax XT moulded case circuit breakers provide compact and dependable protection for industrial and commercial electrical distribution systems, with adjustable thermomagnetic releases offering flexible overload and short-circuit protection for demanding applications.