1SDA075125R1 ABB XT3N 225 TMF 150-1500 4-Pole Circuit Breaker

1SDA075125R1 ABB XT3N 225 TMF 150-1500 4-Pole Circuit Breaker

ABB 1SDA075125R1 XT3N 225 TMF 150-1500 is a 150 A four-pole fixed moulded case circuit breaker with a fully rated neutral, TMF thermomagnetic protection and a 1500 A instantaneous short-circuit setting.

SKU: 1SDA075125R1MPN: 1SDA075125R1
Price
List Price £1,067.35 ex VAT
Your Price (ex VAT) Save 25%
£800.51 25% OFF
You save £266.84 per unit
Manufacturer Lead Time Estimated Delivery 5 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £800.51
Trade pricing is personalised to your account

Manufacturer Lead Time

£800.51

Why Choose the ABB XT3N 225 TMF 150-1500 1SDA075125R1 Circuit Breaker?

The ABB 1SDA075125R1 is a robust four-pole moulded case circuit breaker (MCCB) designed for reliable protection and isolation of low-voltage electrical distribution systems. As part of the ABB SACE Tmax XT / T-Max XT 250 range, this XT3N 225 breaker combines a compact fixed design with dependable thermomagnetic protection for industrial, commercial and infrastructure applications.

This circuit breaker incorporates an ABB TMF thermomagnetic trip unit, providing thermal overload protection together with instantaneous magnetic short-circuit protection. Its fixed installation, front terminals and fully rated neutral make it particularly suitable for three-phase four-wire distribution systems and straightforward integration into switchboards and electrical panels.

With a rated current of 150 A, an instantaneous short-circuit current setting of 1500 A and a rated voltage of 600Y/347 V AC, the XT3N 225 TMF 150-1500 provides dependable protection for demanding power distribution circuits. The N short-circuit performance level and UL/CSA configuration make it suitable for applications requiring North American circuit-breaker specifications.

Key Advantages

  • Robust ABB SACE Tmax XT3 moulded case circuit breaker for low-voltage distribution.
  • 150 A rated current for industrial and commercial power circuits.
  • Four-pole configuration with fully rated neutral for three-phase four-wire systems.
  • Integrated TMF thermomagnetic trip unit provides overload and short-circuit protection.
  • 1500 A instantaneous short-circuit current setting for rapid fault protection.
  • 600Y/347 V AC rated voltage for UL/CSA distribution applications.
  • Fixed installation with front terminals simplifies switchboard and panel integration.

Key Features

  • ABB SACE Tmax XT3N 225 series.
  • 150 A rated current.
  • 1500 A instantaneous short-circuit current setting.
  • Four-pole circuit breaker.
  • Fully rated neutral.
  • TMF thermomagnetic release.
  • 600Y/347 V AC rated voltage.
  • 500 V DC rated operational voltage.
  • N short-circuit performance level.
  • Fixed mounting configuration.
  • Front-positioned main circuit terminals.
  • Bolt connection for the main electrical circuit.
  • Manual toggle operating mechanism.
  • Optional motor operation.
  • IP20 protection rating.
  • Designed for UL/CSA applications.

Reliable Circuit Protection for Electrical Distribution

Moulded case circuit breakers such as the ABB XT3N 225 protect electrical circuits, cables and connected equipment against damaging overcurrents caused by overload and short-circuit conditions. The TMF thermomagnetic release combines thermal protection for sustained overloads with instantaneous magnetic operation during high-current faults, providing dependable circuit protection without requiring a separate electronic trip unit.

The ABB SACE Tmax XT range is engineered for efficient integration into modern low-voltage distribution equipment. The four-pole configuration and fully rated neutral of the 1SDA075125R1 make it especially suitable for three-phase four-wire systems, while its fixed mounting arrangement and front terminals provide a practical solution for switchboard builders, panel builders and industrial electrical installations.

Typical Applications

  • Industrial low-voltage distribution boards.
  • Commercial electrical distribution systems.
  • Three-phase four-wire electrical networks.
  • Electrical switchboards and control panels.
  • Machine and production-line power distribution.
  • Building services and infrastructure installations.
  • OEM machinery and industrial electrical systems.

Technical Specifications

Series SACE Tmax XT / T-Max XT 250 Range
Frame size XT3
ABB order code 1SDA075125R1
Product type Moulded case circuit breaker (MCCB)
Frame rated uninterrupted current (Iu) 225 A
Rated current (In) 150 A
Thermal overload setting 150 A
Instantaneous short-circuit current setting (Ii) 1500 A
Rated voltage 600Y/347 V AC
Rated operational voltage 600Y/347 V AC / 500 V DC
Number of poles 4
Neutral Fully rated
Trip unit TMF thermomagnetic
Release type Thermomagnetic
Short-circuit performance level N
Installation Fixed
Terminal position Front
Terminal type Bolt connection
Operating mechanism Toggle
Motor operation Optional
Integrated earth-fault protection No
Protection rating IP20
Power loss at rated operating conditions per pole 6.9 W
Standard UL / CSA configuration
EAN 8015644791025

Frequently Asked Questions

What is the ABB 1SDA075125R1 used for?

The ABB 1SDA075125R1 is a four-pole moulded case circuit breaker designed to protect low-voltage electrical distribution circuits against overloads and short circuits in industrial, commercial and infrastructure applications.

What is the rated current of the ABB XT3N 225 1SDA075125R1?

The circuit breaker has a rated current of 150 A and uses the ABB XT3 frame with a rated uninterrupted current of 225 A.

What is the short-circuit trip setting of the ABB 1SDA075125R1?

The TMF release has an instantaneous short-circuit current setting of 1500 A, providing rapid magnetic operation during high-current fault conditions.

Does the ABB 1SDA075125R1 have a fully rated neutral?

Yes. This is a four-pole circuit breaker with a fully rated neutral, making it suitable for three-phase four-wire distribution systems where the neutral requires full current-carrying capability.

What type of trip unit does the ABB 1SDA075125R1 use?

The breaker uses an integrated TMF thermomagnetic trip unit, combining thermal overload protection at 150 A with instantaneous magnetic short-circuit protection at 1500 A.

Trusted for Low-Voltage Electrical Protection

ABB SACE Tmax XT moulded case circuit breakers are widely used in industrial, commercial and OEM electrical systems, providing compact and dependable protection for modern low-voltage power distribution equipment.