1SDA074913R1 ABB XT2S 125 Ekip LS/I 100A 3-Pole UL/CSA Circuit Breaker

1SDA074913R1 ABB XT2S 125 Ekip LS/I 100A 3-Pole UL/CSA Circuit Breaker

ABB 1SDA074913R1 XT2S 125 is a fixed three-pole 100 A moulded case circuit breaker with front terminals, an Ekip Dip LS/I solid-state electronic release and a 35 kA interruption rating at 480 V AC for UL/CSA low-voltage applications.

SKU: 1SDA074913R1MPN: 1SDA074913R1
Price
List Price £657.08 ex VAT
Your Price (ex VAT) Save 25%
£492.81 25% OFF
You save £164.27 per unit
Manufacturer Lead Time Estimated Delivery 5 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £492.81
Trade pricing is personalised to your account

Manufacturer Lead Time

£492.81

Why Choose the ABB 1SDA074913R1 XT2S 125 Ekip LS/I 100A 3-Pole Circuit Breaker?

The ABB 1SDA074913R1, designated XT2S 125 Ekip LS/I In=100A 3p F F UL/CSA, is a fixed three-pole moulded case circuit breaker (MCCB) from the ABB SACE Tmax XT range. Built on the XT2S 125 frame, it has a rated current of 100 A and incorporates an Ekip Dip LS/I solid-state electronic trip unit for precise overload and short-circuit protection.

The Ekip LS/I release provides long-time overload (L), short-time short-circuit (S) and instantaneous short-circuit (I) protection functions. Electronic current measurement provides accurate and repeatable protection characteristics, making the breaker suitable for coordinated industrial, commercial and OEM low-voltage distribution systems.

Designed for UL/CSA applications, the 1SDA074913R1 is supplied as a fixed three-pole breaker with front terminals. ABB specifies a rated voltage of 600 V and an XT2S interruption rating of 35 kA at 480 V AC, providing robust protection in a compact 125 A frame.

Key Advantages

  • Genuine ABB SACE Tmax XT2S 125 moulded case circuit breaker.
  • 100 A rated current for low-voltage distribution protection.
  • Ekip Dip LS/I solid-state electronic trip unit for accurate protection.
  • Provides long-time, short-time and instantaneous overcurrent protection functions.
  • XT2S interruption rating of 35 kA at 480 V AC.
  • Rated for systems up to 600 V.
  • Designed for UL/CSA applications.
  • Fixed mounting with front terminals supports straightforward panel and switchboard integration.

Key Features

  • ABB SACE Tmax XT2S 125 frame.
  • 100 A rated current.
  • 3-pole configuration.
  • Ekip Dip LS/I solid-state electronic release.
  • L – long-time overload protection.
  • S – short-time short-circuit protection.
  • I – instantaneous short-circuit protection.
  • 600 V rated voltage.
  • 35 kA at 480 V AC interruption rating.
  • Fixed installation with front terminals.
  • UL-certified configuration for North American applications.

Electronic LS/I Protection for Coordinated Distribution Systems

The Ekip Dip LS/I release uses solid-state electronic current measurement to provide precise protection against the principal overcurrent conditions encountered in low-voltage distribution systems. Long-time protection responds to sustained overloads, short-time protection enables controlled response and coordination during short-circuit conditions, and instantaneous protection provides rapid interruption of severe faults.

For the ABB 1SDA074913R1, these protection functions are combined with a rated current of 100 A and XT2S interruption performance of 35 kA at 480 V AC. This makes the breaker well suited to applications where electronic protection and improved coordination are preferred over conventional thermal-magnetic protection.

Typical Applications

  • Industrial low-voltage distribution panels.
  • Commercial building electrical distribution systems.
  • Three-phase feeder and branch circuits.
  • OEM machinery and electrical equipment.
  • Control panels and power distribution enclosures.
  • Distribution circuits requiring electronic LS/I protection and coordination.
  • UL/CSA-oriented switchboards and electrical assemblies.

Technical Specifications

Series SACE Tmax XT
Product group T-Max XT 250 Range
Frame / size XT2S 125
ABB order code 1SDA074913R1
Alternate catalogue number XT2SU3100EFF000XXX
EAN / GTIN 8015644788902
Product type Moulded case circuit breaker
Application Low-voltage power distribution
Rated current (In) 100 A
Frame rated current 125 A
Number of poles 3
Trip unit Ekip Dip LS/I solid-state electronic release
Protection functions Long-time, short-time and instantaneous (LS/I)
Rated voltage 600 V
Interruption rating S – 35 kA at 480 V AC
Installation Fixed
Main connection Front terminals
Standard / certification UL
Rated configuration 80% rated

Frequently Asked Questions

What is the ABB 1SDA074913R1?

The ABB 1SDA074913R1 is an XT2S 125 three-pole moulded case circuit breaker rated at 100 A, with an Ekip Dip LS/I solid-state electronic release, fixed mounting and front terminals for UL/CSA applications.

What protection functions does the Ekip LS/I trip unit provide?

The Ekip LS/I release provides long-time overload (L), short-time short-circuit (S) and instantaneous short-circuit (I) protection.

What is the interruption rating of the ABB 1SDA074913R1?

The XT2S performance level provides an interruption rating of 35 kA at 480 V AC for this UL configuration.

What is the rated current and voltage of the ABB 1SDA074913R1?

The breaker has a rated current of 100 A and ABB specifies a rated voltage of 600 V.

How is the ABB 1SDA074913R1 installed?

The breaker is supplied as a fixed three-pole unit with front terminals for integration into compatible low-voltage switchboards, distribution panels and electrical equipment.

Trusted ABB Electronic Circuit Protection

ABB SACE Tmax XT moulded case circuit breakers combine compact construction with advanced electronic protection, and the XT2S 125 Ekip LS/I 100 A provides precise long-time, short-time and instantaneous protection for demanding UL/CSA industrial, commercial and OEM low-voltage applications.