1SDA074909R1 ABB XT2N 125 Ekip LS/I In=125A 4p F F UL/CSA Moulded Case Circuit Breaker

1SDA074909R1 ABB XT2N 125 Ekip LS/I In=125A 4p F F UL/CSA Moulded Case Circuit Breaker

ABB XT2N 125 Ekip LS/I In=125A 4p F F UL/CSA moulded case circuit breaker with electronic Ekip LS/I protection for reliable low-voltage AC distribution systems.

SKU: 1SDA074909R1MPN: 1SDA074909R1
Price
List Price £1,191.85 ex VAT
Your Price (ex VAT) Save 25%
£893.89 25% OFF
You save £297.96 per unit
Manufacturer Lead Time Estimated Delivery 5 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £893.89
Trade pricing is personalised to your account

Manufacturer Lead Time

£893.89

Why Choose the ABB XT2N 125 Ekip LS/I In=125A 4p F F UL/CSA Moulded Case Circuit Breaker?

The ABB XT2N 125 Ekip LS/I In=125A 4p F F UL/CSA is an advanced moulded case circuit breaker (MCCB) designed for accurate protection and reliable switching in low-voltage electrical distribution systems. Part of the ABB SACE Tmax XT2 series, it combines a compact fixed MCCB design with an electronic Ekip Dip LS/I trip unit to provide precise long-time, short-time and instantaneous protection functions.

This circuit breaker features a four-pole fixed configuration with front terminals and an Ekip LS/I electronic release rated at 125 A. The electronic trip technology enables accurate protection settings, improved selectivity and enhanced system reliability compared with conventional thermal-magnetic protection solutions.

With a 125 A rated current, XT2 frame size and UL/CSA compliant construction, the ABB XT2N 125 Ekip LS/I In=125A 4p F F UL/CSA is suitable for demanding industrial and commercial power distribution applications requiring dependable circuit protection.

Key Advantages

  • Advanced ABB SACE Tmax XT2 moulded case circuit breaker with electronic protection.
  • Ekip Dip LS/I trip unit provides accurate overload and short-circuit protection.
  • 125 A rated current suitable for low-voltage distribution applications.
  • Four-pole fixed design with front terminals for straightforward installation.
  • UL489 compliant construction for North American electrical installations.
  • Compact XT2 design supports efficient switchboard layouts.

Key Features

  • ABB SACE Tmax XT2 series moulded case circuit breaker.
  • Ekip Dip LS/I electronic trip unit.
  • 125 A rated current.
  • Four-pole (4P) fixed version.
  • Front terminal connection.
  • Long-time, short-time and instantaneous protection functions (LS/I).
  • 600 V AC rated operational voltage.
  • 50/60 Hz frequency compatibility.
  • Designed for UL/CSA certified electrical protection systems.

Reliable Protection for Intelligent Power Distribution

The ABB XT2N Ekip LS/I range combines advanced electronic protection technology with the compact Tmax XT platform. The Ekip Dip trip unit continuously manages protection functions, helping improve electrical system reliability and providing accurate fault response.

Electronic MCCBs such as the XT2N 125 Ekip LS/I provide modern switchboards with dependable protection, improved coordination and enhanced operational control for industrial and commercial power systems.

Typical Applications

  • Industrial electrical distribution boards.
  • Machine control panels and automation systems.
  • Commercial power distribution installations.
  • Equipment feeder protection.
  • Low-voltage switchboards.
  • Industrial AC power protection systems.

Technical Specifications

Series SACE Tmax XT
Order code 1SDA074909R1
Product type Moulded case circuit breaker (MCCB)
Frame size XT2
Number of poles 4P
Rated current (In) 125 A
Rated uninterrupted current (Iu) 125 A
Release type Ekip Dip LS/I electronic trip unit
Protection functions Long-time, short-time and instantaneous protection
Rated operational voltage 600 V AC
Rated frequency 50/60 Hz
Terminal connection Front terminals
Mounting type Fixed installation
Standards UL489

Frequently Asked Questions

What is the ABB XT2N 125 Ekip LS/I In=125A 4p F F UL/CSA used for?

This ABB moulded case circuit breaker provides electronic overload, short-circuit and instantaneous protection for low-voltage AC distribution systems.

What type of trip unit does this circuit breaker use?

The XT2N 125 Ekip LS/I uses an Ekip Dip LS/I electronic trip unit for advanced circuit protection.

How many poles does the ABB XT2N 125 Ekip LS/I have?

This circuit breaker is a four-pole (4P) fixed version with front terminals.

What is the rated current of this ABB MCCB?

The circuit breaker has a rated current of 125 A with an XT2 frame size.

Which standards does this circuit breaker comply with?

The ABB XT2N 125 Ekip LS/I In=125A 4p F F UL/CSA is designed for UL489 compliant electrical installations.

Trusted by Electrical Engineers Worldwide

ABB SACE Tmax XT circuit breakers are trusted worldwide for reliable protection, intelligent monitoring and dependable performance in modern low-voltage electrical distribution systems.