ABB 1SDA074784R1 XT2S 125 is an 80 A four-pole fixed moulded case circuit breaker with front terminals, an adjustable TMA thermomagnetic trip unit, 400-800 A magnetic protection range and 35 kA interruption rating at 480 V AC.

SKU: 1SDA074784R1MPN: 1SDA074784R1
Price
List Price £651.87 ex VAT
Your Price (ex VAT) Save 25%
£488.90 25% OFF
You save £162.97 per unit
Manufacturer Lead Time Estimated Delivery 5 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £488.90
Trade pricing is personalised to your account

Manufacturer Lead Time

£488.90

Why Choose the ABB XT2S 125 TMA 80-400..800 4p F F UL/CSA?

The ABB XT2S 125 TMA 80-400..800 4p F F UL/CSA, order code 1SDA074784R1, is a four-pole moulded case circuit breaker (MCCB) designed for reliable overload and short-circuit protection in low-voltage power distribution systems. Part of the ABB SACE Tmax XT2 range, it combines a compact 125 A frame with an 80 A TMA adjustable thermomagnetic trip unit.

The TMA thermomagnetic release provides adjustable thermal overload protection together with adjustable magnetic short-circuit protection. This configuration has a rated current of 80 A, with thermal adjustment down to 56 A and a magnetic protection setting adjustable from 400–800 A, allowing the protection characteristics to be matched more closely to the connected circuit.

Configured as a four-pole fixed circuit breaker with front terminals, the 1SDA074784R1 is rated at 600 V and provides an interruption rating of 35 kA at 480 V AC. Its UL-certified configuration and adjustable TMA protection make it well suited to industrial machinery, distribution equipment and OEM electrical panels requiring flexible protection within the compact Tmax XT platform.

Key Advantages

  • Compact ABB SACE Tmax XT2S moulded case circuit breaker for low-voltage distribution.
  • 80 A rated current within the XT2 125 A frame.
  • TMA adjustable thermomagnetic release for flexible overload and short-circuit protection.
  • Thermal overload adjustment range of 56–80 A.
  • Adjustable magnetic protection range of 400–800 A.
  • 35 kA interruption rating at 480 V AC.
  • Four-pole fixed construction with front terminals for straightforward panel integration.
  • UL/CSA configuration for applicable North American electrical equipment applications.

Key Features

  • ABB SACE Tmax XT2S 125 MCCB.
  • 80 A rated current.
  • 125 A frame size.
  • 4-pole configuration.
  • TMA adjustable thermomagnetic trip unit.
  • Adjustable thermal overload protection.
  • Adjustable magnetic short-circuit protection.
  • 56–80 A thermal adjustment range.
  • 400–800 A magnetic protection range.
  • S interruption-performance class.
  • 35 kA interruption rating at 480 V AC.
  • Rated voltage of 600 V.
  • Fixed mounting with front terminals.
  • UL-certified configuration.

Adjustable Thermomagnetic Protection for Low-Voltage Distribution

TMA thermomagnetic moulded case circuit breakers combine thermal overload protection with magnetic short-circuit protection while providing adjustment of the protection thresholds. The adjustable thermal element allows the overload setting to be matched to the protected circuit, while the adjustable magnetic element enables the instantaneous response to be coordinated with expected operating and fault currents.

The ABB XT2S 125 1SDA074784R1 combines this adjustable protection with the compact Tmax XT2 platform. Its 80 A rated current, 56–80 A thermal adjustment range, 400–800 A magnetic adjustment range and 35 kA interruption rating at 480 V AC make it a flexible solution for feeders, machinery supplies and four-pole distribution circuits requiring dependable protection.

Typical Applications

  • Industrial low-voltage power distribution systems.
  • Commercial switchboards and distribution panels.
  • Four-pole feeder and branch-circuit protection.
  • Machinery and industrial automation power supplies.
  • Circuits requiring adjustable overload and short-circuit protection.
  • OEM electrical equipment for applicable North American markets.
  • Control panels requiring UL-configured circuit protection.

Technical Specifications

Series SACE Tmax XT
Product group T-Max XT 250 Range
Order code 1SDA074784R1
Alternate catalogue number XT2SU4080BFF000XXX
Product type Moulded case circuit breaker
Frame size XT2
Frame rating 125 A
Performance level S
Rated current (In) 80 A
Number of poles 4
Trip unit TMA adjustable thermomagnetic release
Thermal overload adjustment 56–80 A
Magnetic protection adjustment 400–800 A
Rated voltage 600 V
Interruption rating 35 kA at 480 V AC
Mounting type Fixed
Terminal type Front terminals
Standard UL
Certification UL
EAN / UPC 8015644787615

Frequently Asked Questions

What is the ABB 1SDA074784R1 used for?

The ABB 1SDA074784R1 is an 80 A four-pole moulded case circuit breaker designed to provide adjustable thermomagnetic overload and short-circuit protection in low-voltage electrical distribution systems.

What trip unit is fitted to the ABB XT2S 125 1SDA074784R1?

The circuit breaker is fitted with an ABB TMA adjustable thermomagnetic release, providing adjustable thermal overload protection and adjustable magnetic short-circuit protection.

What does 80-400..800 mean on the XT2S 125 TMA?

The designation identifies an 80 A rated current together with an adjustable magnetic protection range of 400–800 A. The thermal overload setting can also be adjusted over a 56–80 A range.

What is the interruption rating of the ABB XT2S 1SDA074784R1?

The XT2S configuration has an interruption rating of 35 kA at 480 V AC, providing robust short-circuit protection for applicable low-voltage distribution systems.

How is the ABB XT2S 125 TMA 1SDA074784R1 installed?

This version is a fixed four-pole circuit breaker with front terminals, designed for permanent installation within compatible low-voltage switchboards, distribution panels and OEM electrical assemblies.

Trusted ABB Low-Voltage Circuit Protection

ABB SACE Tmax XT moulded case circuit breakers combine compact construction, adjustable protection technology and robust short-circuit interruption performance for industrial, commercial and OEM low-voltage power distribution systems.