1SDA074648R1 ABB XT1N 125 TMF 125-1250 3p F F UL/CSA Moulded Case Circuit Breaker

1SDA074648R1 ABB XT1N 125 TMF 125-1250 3p F F UL/CSA Moulded Case Circuit Breaker

ABB XT1N 125 TMF 125-1250 3p F F UL/CSA moulded case circuit breaker with thermomagnetic protection for reliable low-voltage AC and DC electrical distribution systems.

SKU: 1SDA074648R1Alt SKU: XT1N125TMFMPN: 1SDA074648R1
Price
List Price £451.88 ex VAT
Your Price (ex VAT) Save 25%
£338.91 25% OFF
You save £112.97 per unit
Manufacturer Lead Time Estimated Delivery 5 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £338.91
Trade pricing is personalised to your account

Manufacturer Lead Time

£338.91

Why Choose the ABB XT1N 125 TMF 125-1250 3p F F UL/CSA Moulded Case Circuit Breaker?

The ABB XT1N 125 TMF 125-1250 3p F F UL/CSA is a compact and reliable moulded case circuit breaker (MCCB) designed for dependable protection of low-voltage electrical distribution systems. As part of the advanced ABB SACE Tmax XT1 series, it provides thermal-magnetic protection for industrial, commercial and infrastructure applications requiring reliable circuit interruption and overload protection.

This circuit breaker features a three-pole fixed configuration with front terminals and an integrated TMF thermomagnetic release, combining thermal overload protection with magnetic short-circuit protection. Its compact XT1 frame design enables efficient installation in switchboards while maintaining ABB’s established standards for safety, performance and reliability.

With a 125 A rated current, 125 A frame size, and a 1250 A instantaneous magnetic trip setting, the XT1N 125 TMF 125-1250 3p F F UL/CSA is suitable for AC and DC power distribution applications requiring UL489 and CSA compliant circuit protection.

Key Advantages

  • Compact ABB SACE Tmax XT moulded case circuit breaker for reliable electrical protection.
  • 125 A frame size suitable for industrial and commercial distribution systems.
  • TMF thermomagnetic release provides dependable overload and short-circuit protection.
  • Three-pole fixed design with front terminals for straightforward installation.
  • UL489 and CSA compliant construction for North American electrical installations.
  • Suitable for demanding AC and DC protection applications.

Key Features

  • ABB SACE Tmax XT1 series moulded case circuit breaker.
  • 125 A rated current.
  • 125 A frame size.
  • Three-pole (3P) fixed version.
  • Front terminal connection.
  • TMF thermomagnetic fixed release.
  • 1250 A instantaneous magnetic trip setting.
  • 600Y/347 V AC rated operational voltage.
  • 500 V DC rated voltage.
  • Designed for UL/CSA certified protection applications.

Reliable Protection for Industrial Power Distribution

Moulded case circuit breakers such as the ABB XT1N 125 protect electrical installations by automatically disconnecting circuits during overload and short-circuit conditions. The integrated TMF release combines thermal protection for sustained overloads with magnetic protection for fault currents.

The Tmax XT platform combines compact construction with advanced protection technology, making it suitable for modern switchboards, machinery systems and industrial electrical distribution networks where dependable performance is required.

Typical Applications

  • Industrial electrical distribution boards.
  • Machine control panels and automation systems.
  • Commercial power distribution installations.
  • Motor and equipment feeder protection.
  • Low-voltage switchboards.
  • AC/DC electrical protection systems.

Technical Specifications

Series SACE Tmax XT
Order code 1SDA074648R1
Product type Moulded case circuit breaker (MCCB)
Frame size XT1
Number of poles 3P
Rated current (In) 125 A
Rated uninterrupted current (Iu) 125 A
Release type TMF thermomagnetic release
Release setting 125 A
Magnetic trip setting 1250 A
Rated operational voltage 600Y/347 V AC
Rated DC voltage 500 V DC
Terminal connection Front terminals
Mounting type Fixed installation
Standards UL489 / CSA

Frequently Asked Questions

What is the ABB XT1N 125 TMF 125-1250 3p F F UL/CSA used for?

This ABB moulded case circuit breaker provides overload and short-circuit protection for low-voltage AC and DC electrical distribution systems.

What type of release does this circuit breaker use?

The XT1N 125 TMF 125-1250 3p F F UL/CSA uses a TMF thermomagnetic release for thermal overload and magnetic short-circuit protection.

How many poles does the ABB XT1N 125 have?

This circuit breaker is a three-pole (3P) fixed version with front terminals.

What is the rated current of this ABB MCCB?

The circuit breaker has a rated current of 125 A with a 125 A XT1 frame size.

Which standards does this circuit breaker comply with?

The ABB XT1N 125 TMF 125-1250 3p F F UL/CSA is designed for UL489 and CSA compliant electrical installations.

Trusted by Electrical Engineers Worldwide

ABB SACE Tmax XT circuit breakers are trusted worldwide for reliable protection, compact installation and dependable performance in modern low-voltage electrical distribution systems.