1SDA074637R1 ABB XT1N 125 TMF 30-500 3p F F UL/CSA Moulded Case Circuit Breaker

1SDA074637R1 ABB XT1N 125 TMF 30-500 3p F F UL/CSA Moulded Case Circuit Breaker

ABB XT1N 125 TMF 30-500 3p F F UL/CSA moulded case circuit breaker with thermomagnetic protection for reliable AC and DC electrical distribution applications.

SKU: 1SDA074637R1MPN: 1SDA074637R1
Price
List Price £423.20 ex VAT
Your Price (ex VAT) Save 25%
£317.40 25% OFF
You save £105.80 per unit
Manufacturer Lead Time Estimated Delivery 5 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £317.40
Trade pricing is personalised to your account

Manufacturer Lead Time

£317.40

Why Choose the ABB XT1N 125 TMF 30-500 3p F F UL/CSA Moulded Case Circuit Breaker?

The ABB XT1N 125 TMF 30-500 3p F F UL/CSA is a compact and reliable moulded case circuit breaker (MCCB) designed for dependable protection of low-voltage electrical distribution systems. As part of the advanced ABB SACE Tmax XT1 series, it provides thermal-magnetic protection for industrial, commercial and infrastructure applications requiring reliable circuit interruption and overload protection. :chatgpt-content-reference{index="0"}

This circuit breaker features a three-pole fixed configuration with front terminals and an integrated TMF thermomagnetic release, combining thermal overload protection with magnetic short-circuit protection. Its compact XT1 frame design enables efficient installation in switchboards while maintaining ABB’s established standards for safety and performance. :chatgpt-content-reference{index="1"}

With a 125 A frame size, 30 A rated current, and a short-circuit release setting of 500 A, the XT1N 125 TMF 30-500 3p F F UL/CSA is suitable for AC and DC power distribution applications requiring UL489 and CSA compliant protection. :chatgpt-content-reference{index="2"}

Key Advantages

  • Compact ABB SACE Tmax XT moulded case circuit breaker for reliable electrical protection.
  • 125 A frame size suitable for a wide range of low-voltage distribution applications.
  • TMF thermomagnetic release provides dependable overload and short-circuit protection.
  • Three-pole fixed design with front terminals for straightforward installation.
  • Certified for UL489 and CSA requirements.
  • Suitable for both AC and DC current systems. :chatgpt-content-reference{index="3"}

Key Features

  • ABB SACE Tmax XT1 series moulded case circuit breaker.
  • 30 A rated current.
  • 125 A frame size.
  • Three-pole (3P) fixed version.
  • Front terminal connection.
  • TMF thermal-magnetic fixed release.
  • 500 A instantaneous magnetic trip setting.
  • 600Y/347 V AC rated voltage.
  • 500 V DC rated voltage.
  • Designed for UL/CSA certified electrical installations. :chatgpt-content-reference{index="4"}

Reliable Protection for Industrial Power Distribution

Moulded case circuit breakers such as the ABB XT1N 125 protect electrical installations by automatically disconnecting circuits during overload and short-circuit conditions. The integrated TMF release provides reliable thermal protection for sustained overloads and magnetic protection for high fault currents.

The Tmax XT platform combines compact construction with advanced protection technology, making it suitable for modern switchboards, machinery systems and industrial electrical distribution networks where dependable performance is required.

Typical Applications

  • Industrial electrical distribution boards.
  • Machine control panels and automation systems.
  • Commercial power distribution installations.
  • Motor and equipment feeder protection.
  • Low-voltage switchboards.
  • AC/DC electrical protection systems.

Technical Specifications

Series SACE Tmax XT
Order code 1SDA074637R1
Product type Moulded case circuit breaker (MCCB)
Frame size XT1 / 125 AF
Number of poles 3P
Rated current (In) 30 A
Rated uninterrupted current (Iu) 125 A
Release type TMF thermomagnetic release
Magnetic trip setting (Ii) 500 A
Rated operational voltage 600Y/347 V AC
Rated DC voltage 500 V DC
Interrupting rating 50 kA at 240 V AC, 25 kA at 480 V AC, 18 kA at 600Y/347 V AC
Terminal connection Front terminals
Mounting type Fixed installation
Standards UL489 / CSA
Dimensions (H × W × D) approx. 130 × 76.2 × 70 mm
Weight approx. 1 kg

Frequently Asked Questions

What is the ABB XT1N 125 TMF 30-500 3p F F UL/CSA used for?

This ABB moulded case circuit breaker provides overload and short-circuit protection for low-voltage AC and DC electrical distribution systems.

What type of release does this circuit breaker use?

The XT1N 125 TMF 30-500 3p F F UL/CSA uses a TMF thermomagnetic release for thermal overload and magnetic short-circuit protection.

How many poles does the ABB XT1N 125 have?

This circuit breaker is a three-pole (3P) fixed version with front terminals.

What is the rated current of this ABB MCCB?

The circuit breaker has a rated current of 30 A with a 125 A XT1 frame size.

Which standards does this circuit breaker comply with?

The ABB XT1N 125 TMF 30-500 3p F F UL/CSA is designed for UL489 and CSA compliant installations.