1SDA073666R1 ABB E2.2S 250 Ekip Hi-Touch LSIG 4p WMP Air Circuit Breaker

1SDA073666R1 ABB E2.2S 250 Ekip Hi-Touch LSIG 4p WMP Air Circuit Breaker

ABB 1SDA073666R1 Emax 2 E2.2S 250 four-pole withdrawable moving-part air circuit breaker with Ekip Hi-Touch LSIG electronic protection, 690 V AC operational voltage, 85 kA ultimate breaking capacity at 440 V AC and 66 kA 1-second short-time withstand capability.

SKU: 1SDA073666R1MPN: 1SDA073666R1
Price
List Price £12,356.45 ex VAT
Your Price (ex VAT) Save 25%
£9,267.34 25% OFF
You save £3,089.11 per unit
Manufacturer Lead Time Estimated Delivery 5 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £9,267.34
Trade pricing is personalised to your account

Manufacturer Lead Time

£9,267.34

Why Choose the ABB E2.2S 250 Ekip Hi-Touch LSIG 4p WMP Air Circuit Breaker?

The ABB E2.2S 250 Ekip Hi-Touch LSIG 4p WMP, order code 1SDA073666R1, is a 250 A four-pole withdrawable air circuit breaker moving part from the ABB SACE Emax 2 range. Combining the E2.2 frame with S-level short-circuit performance and the advanced Ekip Hi-Touch LSIG electronic trip unit, it provides comprehensive protection for demanding low-voltage industrial, commercial and infrastructure power-distribution systems.

The E2.2S platform provides an ultimate short-circuit breaking capacity of 85 kA at 440 V AC together with a rated short-time withstand current of 66 kA for 1 s. This combination delivers strong fault-interruption and withstand performance, supporting selective coordination in installations where continuity and dependable protection are important.

The integrated Ekip Hi-Touch LSIG trip unit provides long-time overload (L), short-time selective short-circuit (S), instantaneous short-circuit (I) and ground-fault (G) protection. Supplied as the withdrawable moving part (WMP) in a four-pole configuration, the 1SDA073666R1 is designed for use with the corresponding Emax 2 fixed portion, providing a serviceable architecture for critical switchboards.

Key Advantages

  • 250 A rated uninterrupted current for low-voltage feeder and distribution protection.
  • Four-pole construction for comprehensive switching and protection.
  • 85 kA ultimate breaking capacity at 440 V AC for demanding fault levels.
  • 66 kA 1-second short-time withstand current supports selective fault coordination.
  • Ekip Hi-Touch LSIG electronic protection combines overload, selective short-circuit, instantaneous and ground-fault protection.
  • Advanced touchscreen interface supports intuitive configuration, monitoring and interaction with the trip unit.
  • Withdrawable moving-part construction supports inspection, maintenance and equipment replacement.
  • Part of the proven ABB SACE Emax 2 platform for high-performance low-voltage power distribution.

Key Features

  • ABB SACE Emax 2 E2.2S air circuit breaker moving part.
  • 250 A rated uninterrupted current (Iu).
  • Four-pole configuration.
  • Ekip Hi-Touch LSIG electronic trip unit.
  • Long-time (L) overload protection.
  • Short-time (S) selective short-circuit protection.
  • Instantaneous (I) short-circuit protection.
  • Ground-fault (G) protection.
  • 85 kA ultimate short-circuit breaking capacity (Icu) at 440 V AC.
  • 66 kA rated short-time withstand current (Icw) for 1 s.
  • 690 V AC rated operational voltage.
  • 1000 V AC rated insulation voltage.
  • 12 kV rated impulse withstand voltage.
  • Withdrawable moving part (WMP) configuration.
  • Designed for use with the corresponding Emax 2 fixed portion.
  • Compliant with IEC 60947-2.

Advanced LSIG Protection with Withdrawable Serviceability

The Ekip Hi-Touch LSIG trip unit equips the ABB 1SDA073666R1 with four complementary electronic protection functions. Long-time protection responds to sustained overloads, short-time protection supports selective coordination during short-circuit conditions, instantaneous protection provides rapid intervention against severe faults, and ground-fault protection adds dedicated protection against earth-fault conditions.

The E2.2S frame complements this advanced protection functionality with 85 kA ultimate breaking capacity at 440 V AC and 66 kA 1-second short-time withstand capability. Its withdrawable moving-part construction allows the breaker to be used with the corresponding fixed portion of an Emax 2 assembly, providing a practical architecture for inspection, maintenance and replacement in important power-distribution switchboards.

Typical Applications

  • Main low-voltage distribution switchboards.
  • Industrial power distribution systems.
  • Commercial and infrastructure electrical distribution.
  • Feeder and distribution circuit protection.
  • Transformer secondary protection.
  • Manufacturing and process plant switchgear.
  • Critical-power and serviceable withdrawable switchboards.
  • Systems requiring advanced LSIG protection and selective fault coordination.

Technical Specifications

Series SACE Emax 2
Order code 1SDA073666R1
EAN 8015644775995
Product type Air circuit breaker moving part
Frame E2.2
Performance level S
Rated uninterrupted current (Iu) 250 A
Number of poles 4
Trip unit Ekip Hi-Touch LSIG
Trip-unit technology Electronic
Protection functions L, S, I, G
Rated operational voltage (Ue) 690 V AC
Rated insulation voltage (Ui) 1000 V AC
Rated impulse withstand voltage (Uimp) 12 kV
Ultimate breaking capacity (Icu) at 440 V AC 85 kA
Rated short-time withstand current (Icw), 1 s 66 kA
Installation Withdrawable
Configuration Moving part (WMP)
Standard IEC 60947-2

Frequently Asked Questions

What is the ABB 1SDA073666R1 used for?

The ABB 1SDA073666R1 is an Emax 2 E2.2S withdrawable air circuit breaker moving part designed for switching and comprehensive overload, short-circuit and ground-fault protection in low-voltage power distribution systems.

What is the current rating of the ABB E2.2S 1SDA073666R1?

The E2.2S 1SDA073666R1 has a rated uninterrupted current of 250 A.

What protection functions does the Ekip Hi-Touch LSIG trip unit provide?

The Ekip Hi-Touch LSIG provides long-time overload (L), short-time selective short-circuit (S), instantaneous short-circuit (I) and ground-fault (G) protection.

What is the breaking capacity of the ABB 1SDA073666R1?

The E2.2S frame provides an ultimate short-circuit breaking capacity of 85 kA at 440 V AC and a rated short-time withstand current of 66 kA for 1 s.

What does WMP mean on the ABB E2.2S 250?

WMP identifies the withdrawable moving part of the air circuit breaker, designed for use with the corresponding fixed portion of an ABB Emax 2 withdrawable switchboard assembly.

Trusted ABB Power Distribution Technology

ABB SACE Emax 2 air circuit breakers combine high fault-breaking performance, advanced electronic protection and serviceable switchgear architecture, with the E2.2S 250 Ekip Hi-Touch LSIG providing comprehensive four-pole LSIG protection and withdrawable functionality for demanding low-voltage distribution systems.