1SDA073665R1 ABB E2.2S 250 Ekip Hi-Touch LSI 4p WMP Emax 2 Air Circuit Breaker

1SDA073665R1 ABB E2.2S 250 Ekip Hi-Touch LSI 4p WMP Emax 2 Air Circuit Breaker

ABB 1SDA073665R1 E2.2S 250 Ekip Hi-Touch LSI 4p WMP is a 250 A four-pole withdrawable SACE Emax 2 air circuit breaker moving part with Ekip Hi-Touch LSI electronic protection, operation up to 690 V AC and an 85 kA ultimate short-circuit breaking capacity at 400-440 V AC.

SKU: 1SDA073665R1MPN: 1SDA073665R1
Price
List Price £11,791.22 ex VAT
Your Price (ex VAT) Save 25%
£8,843.42 25% OFF
You save £2,947.81 per unit
Manufacturer Lead Time Estimated Delivery 5 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £8,843.42
Trade pricing is personalised to your account

Manufacturer Lead Time

£8,843.42

Why Choose the ABB E2.2S 250 Ekip Hi-Touch LSI 4p WMP Emax 2 Air Circuit Breaker?

The ABB E2.2S 250 Ekip Hi-Touch LSI 4p WMP, order code 1SDA073665R1, is a 250 A four-pole withdrawable air circuit breaker moving part from the ABB SACE Emax 2 range. It combines the E2.2 frame with S-level short-circuit performance and the advanced Ekip Hi-Touch LSI electronic trip unit for sophisticated protection and management of low-voltage electrical distribution systems.

The E2.2S provides an ultimate short-circuit breaking capacity of 85 kA at 400–440 V AC and 66 kA at 500–690 V AC. Its rated short-time withstand current is 66 kA for 1 s and 50 kA for 3 s, while the service short-circuit breaking capacity is rated at 100% of Icu.

The fitted Ekip Hi-Touch LSI electronic release provides long-time overload protection (L), short-time short-circuit protection (S) and instantaneous short-circuit protection (I). Its four-pole configuration features a neutral pole rated at 100% of Iu, while the withdrawable construction supports efficient inspection, servicing and replacement within compatible ABB SACE Emax 2 switchgear.

Key Advantages

  • 250 A four-pole air circuit breaker for demanding low-voltage power distribution.
  • 85 kA ultimate short-circuit breaking capacity at 400–440 V AC.
  • 66 kA ultimate breaking capacity at 500–690 V AC.
  • 66 kA rated short-time withstand current for 1 s and 50 kA for 3 s.
  • 100% Ics/Icu ratio for robust service short-circuit performance.
  • Ekip Hi-Touch LSI electronic trip unit provides overload, selective short-circuit and instantaneous protection.
  • Four-pole design with a neutral pole rated at 100% of Iu.
  • Withdrawable moving-part construction supports maintenance, inspection and replacement.

Key Features

  • ABB SACE Emax 2 E2.2S series.
  • 250 A rated current.
  • 250 A rated uninterrupted current (Iu).
  • Four-pole configuration.
  • Neutral pole current: 100% of Iu.
  • Withdrawable moving part (WMP).
  • Ekip Hi-Touch LSI electronic release.
  • Long-time (L) overload protection.
  • Short-time (S) short-circuit protection.
  • Instantaneous (I) short-circuit protection.
  • 690 V AC rated operational voltage.
  • 1000 V AC rated insulation voltage.
  • 12 kV rated impulse withstand voltage.
  • IP30 front-side protection.
  • Suitable for IT networks up to 690 V.

Advanced Hi-Touch LSI Protection for Low-Voltage Distribution

The ABB E2.2S 250 combines the high-performance switching and fault-interruption capabilities of the SACE Emax 2 platform with the advanced electronic protection functionality of the Ekip Hi-Touch LSI release. Long-time protection responds to sustained overload conditions, short-time protection supports selective coordination between protective devices, and instantaneous protection provides rapid interruption when severe short-circuit currents occur.

With an ultimate breaking capacity of 85 kA at 400–440 V AC, service breaking capacity equal to 100% of Icu and a rated short-time withstand current of 66 kA for 1 s, the breaker is engineered for distribution systems with substantial prospective fault levels. Its four-pole withdrawable construction further supports maintainable switchgear designs and applications where switching and protection of a four-wire distribution system are required.

Typical Applications

  • Industrial low-voltage switchboards.
  • Main incoming and distribution circuit protection.
  • Four-pole and four-wire power distribution systems.
  • Commercial building electrical distribution.
  • Manufacturing and process facilities.
  • Infrastructure and critical-power systems.
  • Transformer and generator distribution systems.
  • Installations requiring advanced overload, selective short-circuit and instantaneous protection.

Technical Specifications

Series SACE Emax 2
Order code / MPN 1SDA073665R1
Product group Emax2 Air Circuit Breaker
Product type Air circuit breaker moving part
Frame / sub-type E2.2
Short-circuit performance level S
Version W / withdrawable
Number of poles 4
Neutral pole current 100% of Iu
Rated current (In) 250 A
Rated uninterrupted current (Iu) 250 A
Trip unit Ekip Hi-Touch LSI
Release type Electronic (EL)
Protection functions L, S, I
Overload release current setting 100–250 A
Short-time delayed short-circuit release setting 150–2500 A
Instantaneous short-circuit release setting 375–3750 A
Rated operational voltage (Ue) 690 V AC
Rated voltage (Ur) 690 V
Rated insulation voltage (Ui) 1000 V AC
Rated impulse withstand voltage (Uimp) 12 kV
Ultimate short-circuit breaking capacity (Icu) at 400 V AC 85 kA
Ultimate short-circuit breaking capacity (Icu) at 415 V AC 85 kA
Ultimate short-circuit breaking capacity (Icu) at 440 V AC 85 kA
Ultimate short-circuit breaking capacity (Icu) at 500 V AC 66 kA
Ultimate short-circuit breaking capacity (Icu) at 525 V AC 66 kA
Ultimate short-circuit breaking capacity (Icu) at 690 V AC 66 kA
Service short-circuit breaking capacity (Ics) at 400–440 V AC 85 kA
Service short-circuit breaking capacity (Ics) at 500–690 V AC 66 kA
Ics as percentage of Icu 100%
Rated short-time withstand current (Icw) 66 kA for 1 s
Rated short-time withstand current 50 kA for 3 s
Power loss 100 W
Auxiliary change-over contacts 4
Integrated earth-fault protection No
Operating element Push button
Motor drive Optional
Protection rating IP30
Suitable for IT networks Yes, up to 690 V
EAN 8015644775988
Standard IEC 60947-2

Frequently Asked Questions

What is the ABB 1SDA073665R1 used for?

The ABB 1SDA073665R1 is a four-pole withdrawable SACE Emax 2 air circuit breaker moving part designed for switching and advanced electronic protection in low-voltage electrical distribution systems.

What is the current rating of the E2.2S 250 Ekip Hi-Touch LSI?

The circuit breaker has a rated uninterrupted current of 250 A. Its four-pole configuration includes a neutral pole rated at 100% of Iu.

What is the breaking capacity of the ABB E2.2S 250?

The breaker has an ultimate short-circuit breaking capacity of 85 kA at 400–440 V AC and 66 kA at 500–690 V AC. Its service short-circuit breaking capacity is rated at 100% of Icu.

What protection does the Ekip Hi-Touch LSI trip unit provide?

The Ekip Hi-Touch LSI provides long-time overload protection, short-time short-circuit protection and instantaneous short-circuit protection, represented by the L, S and I functions.

Is the ABB 1SDA073665R1 fixed or withdrawable?

The ABB 1SDA073665R1 is a four-pole withdrawable moving part designed for use with a compatible ABB SACE Emax 2 E2.2 fixed part.

Trusted ABB Circuit Protection Technology

ABB SACE Emax 2 air circuit breakers combine high short-circuit performance, advanced electronic protection and maintainable withdrawable construction for dependable low-voltage power distribution in industrial, commercial, infrastructure and critical-power applications.