1SDA073646R1 ABB E2.2S 250 Ekip Hi-Touch LSIG 4p F HR Air Circuit Breaker 250 A

1SDA073646R1 ABB E2.2S 250 Ekip Hi-Touch LSIG 4p F HR Air Circuit Breaker 250 A

ABB 1SDA073646R1 E2.2S 250 Ekip Hi-Touch LSIG 4p F HR is a 250 A four-pole fixed SACE Emax 2 air circuit breaker with advanced LSIG electronic protection, integrated measurement and an 85 kA ultimate breaking capacity at 440 V AC.

SKU: 1SDA073646R1MPN: 1SDA073646R1
Price
List Price £12,570.79 ex VAT
Your Price (ex VAT) Save 25%
£9,428.09 25% OFF
You save £3,142.70 per unit
Manufacturer Lead Time Estimated Delivery 5 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £9,428.09
Trade pricing is personalised to your account

Manufacturer Lead Time

£9,428.09

Why Choose the ABB E2.2S 250 Ekip Hi-Touch LSIG 4p F HR Air Circuit Breaker?

The ABB E2.2S 250 Ekip Hi-Touch LSIG 4p F HR, order code 1SDA073646R1, is a high-performance four-pole fixed air circuit breaker from the ABB SACE Emax 2 range, designed for advanced protection, monitoring and control of low-voltage power distribution systems. Rated at 250 A, it combines the E2.2S performance level with the sophisticated Ekip Hi-Touch LSIG electronic trip unit.

The Ekip Hi-Touch LSIG release provides long-time, short-time, instantaneous and earth-fault protection together with advanced measurement capabilities. Integrated Ekip Measuring Pro and Network Analyzer functionality support detailed electrical monitoring, while the touch-sensitive display provides an accessible interface for protection settings, measurements and system information.

The E2.2S frame provides an ultimate short-circuit breaking capacity of 85 kA at 440 V AC and 66 kA at 690 V AC, together with a rated short-time withstand current of 66 kA for 1 s. Its fixed four-pole construction and rear horizontal terminals make the 1SDA073646R1 particularly suitable for sophisticated industrial, commercial and infrastructure distribution switchboards.

Key Advantages

  • 250 A ABB SACE Emax 2 air circuit breaker for advanced low-voltage power distribution.
  • Ekip Hi-Touch LSIG electronic trip unit provides comprehensive overload, short-circuit and earth-fault protection.
  • 85 kA ultimate short-circuit breaking capacity at 440 V AC.
  • 66 kA ultimate short-circuit breaking capacity at 690 V AC.
  • 66 kA short-time withstand current for 1 s supports demanding selective distribution systems.
  • Integrated Ekip Measuring Pro and Network Analyzer functionality for advanced electrical monitoring.
  • Four-pole fixed construction with 100% neutral pole current capability.
  • Rear horizontal terminals support practical switchboard and busbar integration.

Key Features

  • ABB SACE Emax 2 E2.2S series.
  • 250 A rated uninterrupted current (Iu).
  • Four-pole construction.
  • 100% neutral pole current rating.
  • 690 V AC rated operational voltage (Ue).
  • 1000 V AC rated insulation voltage (Ui).
  • 12 kV rated impulse withstand voltage (Uimp).
  • Ekip Hi-Touch LSIG electronic protection release.
  • Long-time (L), short-time (S), instantaneous (I) and earth-fault (G) protection.
  • Ekip Measuring Pro integrated measurement functionality.
  • Network Analyzer functionality for advanced power-quality monitoring.
  • 85 kA Icu at 380–440 V AC.
  • 66 kA Icu at 500–690 V AC.
  • 66 kA Icw for 1 s and 50 kA Icw for 3 s.
  • Fixed (F) installation version with rear horizontal terminals.

Advanced LSIG Protection and Power Monitoring

Air circuit breakers protect low-voltage distribution systems by interrupting abnormal currents before cables, busbars and connected equipment are exposed to unacceptable thermal or electrodynamic stress. The ABB E2.2S 250 combines high short-circuit performance with an advanced electronic protection platform, delivering an 85 kA breaking capacity at 440 V AC and comprehensive LSIG protection for demanding distribution networks.

The Ekip Hi-Touch LSIG trip unit provides adjustable long-time overload, short-time selective, instantaneous short-circuit and earth-fault protection. Its integrated Ekip Measuring Pro and Network Analyzer functions extend the breaker beyond circuit protection by providing detailed electrical measurements and power-quality information for monitoring and management of modern electrical installations.

Typical Applications

  • Main and sub-main low-voltage power distribution switchboards.
  • Industrial manufacturing and process facilities.
  • Commercial buildings and critical infrastructure.
  • Data centres and high-availability electrical distribution systems.
  • Feeder protection requiring advanced LSIG functionality.
  • Installations requiring integrated electrical measurement and power-quality analysis.

Technical Specifications

Series SACE Emax 2
Order code / Product ID 1SDA073646R1
Product type Air circuit breaker
ABB product group Emax2 Air Circuit Breaker
Frame E2.2
Short-circuit performance level S
Rated current (In) 250 A
Rated uninterrupted current (Iu) 250 A
Rated operational voltage (Ue) 690 V AC
Rated insulation voltage (Ui) 1000 V AC
Rated impulse withstand voltage (Uimp) 12 kV
Rated ultimate short-circuit breaking capacity (Icu), 380–440 V AC 85 kA
Rated ultimate short-circuit breaking capacity (Icu), 500–690 V AC 66 kA
Rated service short-circuit breaking capacity (Ics) 100% of Icu
Rated short-time withstand current (Icw), 1 s 66 kA
Rated short-time withstand current (Icw), 3 s 50 kA
Number of poles 4
Neutral pole current 100% of Iu
Current type AC
Trip unit Ekip Hi-Touch LSIG
Release type Electronic
Protection functions Long-time (L), short-time (S), instantaneous (I) and earth-fault (G)
Integrated measurement Ekip Measuring Pro
Power-quality analysis Network Analyzer
Installation version Fixed (F)
Terminal configuration Rear flat horizontal (HR)
Electrical durability at ≤440 V 15,000 cycles
Electrical durability at 500–690 V 15,000 cycles
Mechanical durability 25,000 cycles
Power loss 50 W
Product depth 270 mm
Net weight 53 kg
Standard IEC 60947-2
EAN 8015644775797

Frequently Asked Questions

What is the ABB 1SDA073646R1 used for?

The ABB 1SDA073646R1 is a 250 A four-pole fixed air circuit breaker designed for advanced protection, switching, monitoring and control in low-voltage power distribution systems.

What protection functions does the Ekip Hi-Touch LSIG trip unit provide?

The Ekip Hi-Touch LSIG trip unit provides long-time (L), short-time (S), instantaneous (I) and earth-fault (G) protection, together with advanced measurement and monitoring capabilities.

What is the breaking capacity of the ABB E2.2S 250?

The E2.2S 250 has a rated ultimate short-circuit breaking capacity of 85 kA at 380–440 V AC and 66 kA at 500–690 V AC.

What is the short-time withstand current of the E2.2S 250?

The E2.2S 250 has a rated short-time withstand current of 66 kA for 1 s and 50 kA for 3 s.

Does the ABB 1SDA073646R1 include advanced measurement functions?

Yes. The Ekip Hi-Touch configuration includes Ekip Measuring Pro and Network Analyzer functionality, providing advanced electrical measurement and power-quality monitoring alongside the breaker protection functions.

Trusted ABB Low-Voltage Circuit Protection Technology

ABB SACE Emax 2 air circuit breakers combine high short-circuit performance, advanced electronic protection, integrated measurement and flexible switchboard integration, providing dependable protection and control for sophisticated industrial, commercial and infrastructure low-voltage power distribution systems.