1SDA073644R1 ABB E2.2S 250 Ekip G Touch LSIG 4p FHR Air Circuit Breaker

1SDA073644R1 ABB E2.2S 250 Ekip G Touch LSIG 4p FHR Air Circuit Breaker

ABB 1SDA073644R1 E2.2S 250 Ekip G Touch LSIG 4p FHR is a 250 A four-pole fixed SACE Emax 2 air circuit breaker with horizontal rear terminals, advanced LSIG electronic protection and 85 kA ultimate breaking capacity at 400/415 V AC.

SKU: 1SDA073644R1MPN: 1SDA073644R1
Price
List Price £12,278.51 ex VAT
Your Price (ex VAT) Save 25%
£9,208.88 25% OFF
You save £3,069.63 per unit
Manufacturer Lead Time Estimated Delivery 5 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £9,208.88
Trade pricing is personalised to your account

Manufacturer Lead Time

£9,208.88

Why Choose the ABB E2.2S 250 Ekip G Touch LSIG 4p FHR Air Circuit Breaker?

The ABB E2.2S 250 Ekip G Touch LSIG 4p FHR, order code 1SDA073644R1, is a 250 A four-pole fixed SACE Emax 2 air circuit breaker designed for advanced protection and switching in low-voltage power distribution systems. It combines the E2.2S frame with an Ekip G Touch LSIG electronic trip unit and horizontal rear terminals for integration into fixed switchboard assemblies.

The fitted Ekip G Touch LSIG release provides long-time overload, short-time short-circuit, instantaneous short-circuit and earth-fault protection. The G Touch platform is designed for applications requiring advanced protection and generator-oriented functionality, while its electronic interface enables detailed configuration and management of the breaker protection functions.

With a rated uninterrupted current of 250 A, rated voltage of 690 V, ultimate short-circuit breaking capacity of 85 kA at 400 / 415 V AC and rated short-time withstand current of 66 kA for 1 s, the E2.2S 250 provides robust protection for industrial, commercial, infrastructure and power-generation distribution systems.

Key Advantages

  • 250 A rated uninterrupted current for low-voltage power distribution circuits.
  • Ekip G Touch LSIG electronic trip unit provides comprehensive overcurrent and earth-fault protection.
  • Long-time (L) protection safeguards circuits against sustained overload conditions.
  • Short-time (S) and instantaneous (I) protection provide configurable short-circuit protection.
  • Ground-fault (G) protection adds protection against earth-fault currents.
  • High ultimate breaking capacity of 85 kA at 400 / 415 V AC.
  • Four-pole fixed construction supports three-phase systems requiring neutral switching.
  • Horizontal rear terminals suit rear-connected switchboard and busbar arrangements.
  • Part of ABB's established SACE Emax 2 air circuit breaker platform.

Key Features

  • ABB SACE Emax 2 E2.2S air circuit breaker.
  • 250 A rated uninterrupted current.
  • Four-pole configuration.
  • Fixed installation.
  • Horizontal rear terminals.
  • Ekip G Touch LSIG electronic release.
  • L, S, I and G protection functions.
  • 690 V rated voltage.
  • 85 kA Icu at 400 / 415 V AC.
  • 66 kA Icw for 1 s and 50 kA Icw for 3 s.

Advanced LSIG Protection for Power Distribution

The Ekip G Touch LSIG electronic release provides a comprehensive protection package for demanding distribution and generation applications. Long-time protection responds to sustained overloads, short-time protection supports selective coordination, instantaneous protection responds rapidly to severe short circuits, and the ground-fault function detects earth-fault conditions that may not be adequately addressed by phase overcurrent protection alone.

The E2.2S performance level provides an ultimate short-circuit breaking capacity of 85 kA at 400 / 415 V AC together with a rated short-time withstand current of 66 kA for 1 s. Combined with four-pole fixed construction and horizontal rear terminals, ABB 1SDA073644R1 is well suited to switchboards requiring advanced LSIG protection, high breaking performance and dependable neutral switching.

Typical Applications

  • Low-voltage main and sub-distribution switchboards.
  • Generator and power-generation distribution systems.
  • Industrial three-phase systems requiring neutral switching.
  • Manufacturing and process plant electrical distribution.
  • Commercial and infrastructure low-voltage switchgear.
  • Power distribution systems requiring advanced LSIG electronic protection and high short-circuit performance.

Technical Specifications

Series SACE Emax 2 E2.2
ABB order code 1SDA073644R1
EAN / GTIN 8015644775773
Product type Air circuit breaker
Frame / subtype E2.2
Short-circuit performance level S
Rated uninterrupted current (Iu) 250 A
Rated voltage (Ur) 690 V
Ultimate short-circuit breaking capacity (Icu) at 400 V AC 85 kA
Ultimate short-circuit breaking capacity (Icu) at 415 V AC 85 kA
Ultimate short-circuit breaking capacity (Icu) at 440 V AC 85 kA
Ultimate short-circuit breaking capacity (Icu) at 500 V AC 66 kA
Ultimate short-circuit breaking capacity (Icu) at 525 V AC 66 kA
Ultimate short-circuit breaking capacity (Icu) at 690 V AC 66 kA
Rated service short-circuit breaking capacity (Ics) 100% of Icu
Rated short-time withstand current (Icw), 1 s 66 kA
Rated short-time withstand current (Icw), 3 s 50 kA
Trip unit Ekip G Touch LSIG
Release type Electronic (EL)
Protection functions Long-time (L), short-time (S), instantaneous (I), ground fault (G)
Overload release adjustment range 100–250 A
Short-circuit release adjustment range 150–2500 A
Number of poles 4
Installation Fixed
Terminal connection Rear flat horizontal
Auxiliary contacts 4
Suitable for IT networks Yes, up to 690 V
Standard IEC

Frequently Asked Questions

What is the ABB 1SDA073644R1?

The ABB 1SDA073644R1 is an E2.2S 250 Ekip G Touch LSIG four-pole fixed SACE Emax 2 air circuit breaker with horizontal rear terminals and a rated uninterrupted current of 250 A.

What protection functions does the Ekip G Touch LSIG trip unit provide?

The Ekip G Touch LSIG release provides long-time overload (L), short-time short-circuit (S), instantaneous short-circuit (I) and ground-fault (G) protection.

What is the breaking capacity of the ABB E2.2S 250?

The breaker has an ultimate short-circuit breaking capacity of 85 kA at 400 / 415 V AC and 66 kA at 500–690 V AC, with its rated service breaking capacity equal to 100% of Icu.

What is the short-time withstand current of ABB 1SDA073644R1?

The E2.2S 250 has a rated short-time withstand current of 66 kA for 1 s and 50 kA for 3 s.

What does FHR mean on the ABB E2.2S 250?

FHR identifies this configuration as a fixed circuit breaker with horizontal rear terminals, providing rear-facing main connections for integration into compatible switchboard assemblies.

Is the ABB 1SDA073644R1 a four-pole circuit breaker?

Yes. ABB 1SDA073644R1 is a four-pole air circuit breaker, making it suitable for three-phase distribution systems where the neutral conductor also requires switching.

Trusted by Power Distribution Professionals Worldwide

ABB SACE Emax 2 air circuit breakers combine high breaking performance, advanced electronic protection and flexible installation options for dependable low-voltage power distribution and generation applications.