1SDA073640R1 ABB E2.2S 250 Ekip Dip LSIG 4p FHR Air Circuit Breaker

1SDA073640R1 ABB E2.2S 250 Ekip Dip LSIG 4p FHR Air Circuit Breaker

ABB 1SDA073640R1 Emax 2 E2.2S 250 four-pole fixed air circuit breaker with Ekip Dip LSIG electronic protection, rear horizontal terminals, 690 V AC operational voltage and 85 kA ultimate breaking capacity at 400/415 V AC.

SKU: 1SDA073640R1MPN: 1SDA073640R1
Price
List Price £8,965.24 ex VAT
Your Price (ex VAT) Save 25%
£6,723.93 25% OFF
You save £2,241.31 per unit
Manufacturer Lead Time Estimated Delivery 5 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £6,723.93
Trade pricing is personalised to your account

Manufacturer Lead Time

£6,723.93

Why Choose the ABB E2.2S 250 Ekip Dip LSIG 4p FHR Air Circuit Breaker?

The ABB E2.2S 250 Ekip Dip LSIG 4p FHR, order code 1SDA073640R1, is a 250 A four-pole fixed air circuit breaker from the ABB SACE Emax 2 range. Combining the E2.2 frame with S-level breaking performance and an Ekip Dip LSIG electronic trip unit, it provides comprehensive protection and switching for low-voltage industrial, commercial and infrastructure power distribution systems.

The E2.2S platform provides a rated ultimate short-circuit breaking capacity of 85 kA at 380–440 V AC and 66 kA at 500–690 V AC, together with a rated short-time withstand current of 66 kA for 1 s. These characteristics make the breaker suitable for distribution systems requiring strong fault-clearing capability and selective coordination.

The integrated Ekip Dip LSIG trip unit provides long-time overload, short-time selective short-circuit, instantaneous short-circuit and earth-fault protection. Settings are configured through DIP switches, providing a practical means of adapting the breaker protection to the requirements of the electrical installation.

Key Advantages

  • 250 A rated current for low-voltage power distribution and feeder protection.
  • Four-pole construction provides switching and protection across a four-pole circuit.
  • 85 kA ultimate breaking capacity at 380–440 V AC for demanding fault levels.
  • 66 kA breaking capacity at 500–690 V AC extends protection across higher-voltage networks.
  • 66 kA 1-second short-time withstand current supports selective system coordination.
  • Ekip Dip LSIG electronic trip unit combines overload, selective short-circuit, instantaneous and earth-fault protection.
  • DIP-switch adjustment provides straightforward protection configuration.
  • Fixed installation with rear horizontal terminals supports clean switchboard integration.

Key Features

  • ABB SACE Emax 2 E2.2S air circuit breaker.
  • 250 A rated current.
  • Four-pole configuration.
  • Ekip Dip LSIG electronic protection trip unit.
  • Long-time (L) overload protection.
  • Short-time (S) selective short-circuit protection.
  • Instantaneous (I) short-circuit protection.
  • Ground-fault (G) protection.
  • 85 kA Icu at 380/400/415/440 V AC.
  • 66 kA Icu at 500/525/690 V AC.
  • 66 kA rated short-time withstand current (Icw) for 1 s.
  • 690 V AC rated operational voltage (Ue).
  • 1000 V AC rated insulation voltage (Ui).
  • 50/60 Hz rated frequency.
  • Fixed installation.
  • Rear horizontal terminals (FHR).

Reliable LSIG Protection for Low-Voltage Distribution

The Ekip Dip LSIG trip unit gives the ABB 1SDA073640R1 four complementary protection functions. Long-time protection responds to sustained overload conditions, short-time protection enables selective response to short-circuit currents, instantaneous protection provides rapid intervention for severe faults, and ground-fault protection detects earth-fault conditions. This combination supports comprehensive protection of low-voltage distribution circuits.

The E2.2S frame complements this protection functionality with substantial fault-interruption performance, including 85 kA Icu at 400/415 V AC and a 66 kA 1-second short-time withstand rating. Its fixed construction and rear horizontal terminals make it particularly suitable for permanent integration into main distribution boards and industrial switchgear assemblies.

Typical Applications

  • Main low-voltage distribution switchboards.
  • Industrial power distribution systems.
  • Commercial building electrical distribution.
  • Feeder and distribution circuit protection.
  • Transformer secondary protection.
  • Manufacturing and process plant switchgear.
  • Infrastructure and utility distribution assemblies.
  • Systems requiring LSIG protection and selective fault coordination.

Technical Specifications

Series SACE Emax 2
Order code 1SDA073640R1
Product type Air circuit breaker
Frame E2.2
Performance level S
Rated current 250 A
Number of poles 4
Trip unit Ekip Dip LSIG
Protection functions L, S, I, G
Long-time overload setting 0.4–1 × In
Instantaneous protection setting 1.5–15 × In
Earth-fault protection setting 0.1–1 × In
Rated operational voltage (Ue) 690 V AC
Rated insulation voltage (Ui) 1000 V AC
Rated frequency 50/60 Hz
Ultimate breaking capacity (Icu) at 380 V AC 85 kA
Ultimate breaking capacity (Icu) at 400/415 V AC 85 kA
Ultimate breaking capacity (Icu) at 440 V AC 85 kA
Ultimate breaking capacity (Icu) at 500/525 V AC 66 kA
Ultimate breaking capacity (Icu) at 690 V AC 66 kA
Rated short-time withstand current (Icw), 1 s 66 kA
Installation Fixed
Terminal arrangement Rear horizontal (FHR)
Protection adjustment DIP switches

Frequently Asked Questions

What is the ABB 1SDA073640R1 used for?

The ABB 1SDA073640R1 is an Emax 2 E2.2S air circuit breaker designed for switching and comprehensive overload, short-circuit and earth-fault protection in low-voltage power distribution systems.

What is the current rating of the ABB E2.2S 1SDA073640R1?

This E2.2S air circuit breaker has a rated current of 250 A.

What protection functions does the Ekip Dip LSIG trip unit provide?

The Ekip Dip LSIG provides long-time overload (L), short-time short-circuit (S), instantaneous short-circuit (I) and ground-fault (G) protection.

What is the breaking capacity of the ABB 1SDA073640R1?

The breaker has an ultimate short-circuit breaking capacity of 85 kA at 380–440 V AC and 66 kA at 500–690 V AC.

What does FHR mean on the ABB E2.2S 250?

FHR identifies this model as a fixed breaker with rear horizontal terminals, providing a permanent switchboard installation with rear-connected main conductors.

Trusted ABB Power Distribution Technology

ABB SACE Emax 2 air circuit breakers combine dependable switching, high fault-breaking performance and configurable electronic protection, with the E2.2S 250 Ekip Dip LSIG providing comprehensive four-pole protection for demanding low-voltage distribution systems.