1SDA073638R1 ABB E2.2S 250 Ekip Dip LI 4p F HR Emax 2 Air Circuit Breaker

1SDA073638R1 ABB E2.2S 250 Ekip Dip LI 4p F HR Emax 2 Air Circuit Breaker

ABB 1SDA073638R1 E2.2S 250 Ekip Dip LI 4p F HR is a 250 A four-pole fixed SACE Emax 2 air circuit breaker with rear horizontal terminals, Ekip Dip LI electronic protection, a rated operational voltage of 690 V AC and an 85 kA ultimate breaking capacity at 400/415 V AC.

SKU: 1SDA073638R1MPN: 1SDA073638R1
Price
List Price £7,932.31 ex VAT
Your Price (ex VAT) Save 25%
£5,949.23 25% OFF
You save £1,983.08 per unit
Manufacturer Lead Time Estimated Delivery 5 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £5,949.23
Trade pricing is personalised to your account

Manufacturer Lead Time

£5,949.23

Why Choose the ABB E2.2S 250 Ekip Dip LI 4p F HR Emax 2 Air Circuit Breaker?

The ABB E2.2S 250 Ekip Dip LI 4p F HR, order code 1SDA073638R1, is a 250 A four-pole fixed air circuit breaker from the ABB SACE Emax 2 range. Designed for low-voltage power distribution, it combines the E2.2 frame with S-level breaking performance, rear horizontal terminals and the electronic Ekip Dip LI trip unit.

This Emax 2 circuit breaker provides a rated ultimate short-circuit breaking capacity of 85 kA at 400/415 V AC and 66 kA at 690 V AC. Its rated short-time withstand current is 66 kA for 1 s, providing robust fault-handling performance for industrial, commercial and infrastructure distribution systems.

The fitted Ekip Dip LI electronic protection release provides adjustable long-time overload protection (L) and instantaneous short-circuit protection (I). Protection settings are configured using DIP switches, providing straightforward adjustment while retaining dependable electronic protection for the connected electrical distribution system.

Key Advantages

  • 250 A four-pole air circuit breaker for low-voltage power distribution.
  • 85 kA ultimate breaking capacity at 400/415 V AC.
  • 66 kA breaking capacity at 690 V AC.
  • 66 kA rated short-time withstand current for 1 s.
  • Ekip Dip LI electronic trip unit provides overload and instantaneous short-circuit protection.
  • Long-time protection adjustable from 0.4–1 × In.
  • Instantaneous protection adjustable from 1.5–15 × In.
  • Four-pole fixed construction with rear horizontal terminals for switchboard installation.

Key Features

  • ABB SACE Emax 2 E2.2S series.
  • 250 A rated current.
  • Four-pole configuration.
  • Fixed installation.
  • Rear horizontal terminals.
  • Ekip Dip LI solid-state electronic release.
  • Long-time (L) overload protection.
  • Instantaneous (I) short-circuit protection.
  • 690 V AC rated operational voltage (Ue).
  • 1000 V AC rated insulation voltage (Ui).
  • 50/60 Hz rated frequency.
  • Protection settings configured using DIP switches.
  • Supplied with four auxiliary contacts.
  • Open/closed circuit-breaker position indication.
  • Designed in accordance with IEC 60947-2.

Reliable Electronic Protection for Low-Voltage Distribution

The ABB E2.2S 250 combines the switching and fault-interruption capabilities of an Emax 2 air circuit breaker with the electronic protection functions of the Ekip Dip LI release. The long-time protection function responds to sustained overload conditions, while the instantaneous function provides rapid operation when high short-circuit currents are detected.

With an ultimate breaking capacity of 85 kA at 400/415 V AC, the breaker is suitable for distribution systems with substantial prospective fault levels. Its fixed four-pole construction and rear horizontal terminals provide a practical arrangement for permanent installation in compatible low-voltage switchboards and power distribution assemblies.

Typical Applications

  • Industrial low-voltage switchboards.
  • Main incoming and distribution circuit protection.
  • Four-pole power distribution systems.
  • Commercial building electrical distribution.
  • Manufacturing and process facilities.
  • Infrastructure power distribution.
  • Generator and transformer distribution systems.
  • Installations requiring adjustable electronic overload and instantaneous short-circuit protection.

Technical Specifications

Series SACE Emax 2
Order code / MPN 1SDA073638R1
Product type Air circuit breaker
Frame E2.2
Performance level S
Rated current (In) 250 A
Number of poles 4
Installation Fixed
Terminal arrangement Rear horizontal
Trip unit Ekip Dip LI
Protection functions L, I
Long-time overload setting 0.4–1 × In
Instantaneous protection setting 1.5–15 × In
Rated operational voltage (Ue) 690 V AC
Rated insulation voltage (Ui) 1000 V AC
Rated frequency 50/60 Hz
Ultimate short-circuit breaking capacity (Icu) at 380 V AC 85 kA
Ultimate short-circuit breaking capacity (Icu) at 400/415 V AC 85 kA
Ultimate short-circuit breaking capacity (Icu) at 440 V AC 85 kA
Ultimate short-circuit breaking capacity (Icu) at 500/525 V AC 66 kA
Ultimate short-circuit breaking capacity (Icu) at 690 V AC 66 kA
Rated short-time withstand current (Icw) 66 kA for 1 s
Auxiliary contacts 4
Position indication Circuit breaker open/closed
EAN 8015644775711
Standard IEC 60947-2

Frequently Asked Questions

What is the ABB 1SDA073638R1 used for?

The ABB 1SDA073638R1 is a four-pole fixed SACE Emax 2 air circuit breaker designed for switching, overload protection and short-circuit protection in low-voltage electrical distribution systems.

What is the current rating of the E2.2S 250 Ekip Dip LI?

The circuit breaker has a rated current of 250 A and uses an Ekip Dip LI electronic protection release.

What is the breaking capacity of the ABB E2.2S 250?

The breaker has an ultimate short-circuit breaking capacity of 85 kA at 380–440 V AC and 66 kA at 500–690 V AC.

What protection does the Ekip Dip LI trip unit provide?

The Ekip Dip LI provides long-time overload protection and instantaneous short-circuit protection. The long-time threshold is adjustable from 0.4–1 × In, while instantaneous protection is adjustable from 1.5–15 × In.

Is the ABB 1SDA073638R1 fixed or withdrawable?

The 1SDA073638R1 is a fixed four-pole Emax 2 circuit breaker with rear horizontal terminals.

Trusted ABB Circuit Protection Technology

ABB SACE Emax 2 air circuit breakers combine high breaking performance, electronic protection and flexible installation options for dependable low-voltage power distribution in industrial, commercial and infrastructure applications.