1SDA073629R1 ABB E2.2S 250 Ekip Dip LSI 3p FHR Air Circuit Breaker

1SDA073629R1 ABB E2.2S 250 Ekip Dip LSI 3p FHR Air Circuit Breaker

ABB 1SDA073629R1 E2.2S 250 Ekip Dip LSI 3p FHR is a 250 A three-pole fixed SACE Emax 2 air circuit breaker with horizontal rear terminals, LSI electronic protection and 85 kA ultimate breaking capacity at 400/415 V AC.

SKU: 1SDA073629R1MPN: 1SDA073629R1
Price
List Price £6,645.97 ex VAT
Your Price (ex VAT) Save 25%
£4,984.48 25% OFF
You save £1,661.49 per unit
Manufacturer Lead Time Estimated Delivery 5 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £4,984.48
Trade pricing is personalised to your account

Manufacturer Lead Time

£4,984.48

Why Choose the ABB E2.2S 250 Ekip Dip LSI 3p FHR Air Circuit Breaker?

The ABB E2.2S 250 Ekip Dip LSI 3p FHR, order code 1SDA073629R1, is a 250 A three-pole fixed SACE Emax 2 air circuit breaker designed for protection and switching in low-voltage power distribution systems. It combines the ABB E2.2S frame with an Ekip Dip LSI electronic trip unit and horizontal rear terminals for integration into fixed switchboard assemblies.

The fitted Ekip Dip LSI release provides long-time overload, selective short-time short-circuit and instantaneous short-circuit protection. The long-time threshold is adjustable from 0.4–1 × In, while the protection settings are configured using DIP switches for straightforward coordination with downstream and upstream protective devices.

With a rated operational voltage of 690 V AC, rated insulation voltage of 1000 V AC, ultimate short-circuit breaking capacity of 85 kA at 400 / 415 V AC and rated short-time withstand current of 66 kA for 1 s, the E2.2S 250 provides robust protection for industrial, commercial and infrastructure power distribution systems.

Key Advantages

  • 250 A rated current for low-voltage power distribution circuits.
  • Ekip Dip LSI electronic trip unit provides three-stage overcurrent protection.
  • Long-time (L) protection protects circuits against sustained overload conditions.
  • Short-time (S) protection supports selective short-circuit protection and coordination.
  • Instantaneous (I) protection responds rapidly to high short-circuit currents.
  • High ultimate breaking capacity of 85 kA at 400 / 415 V AC.
  • Three-pole fixed construction for three-phase power distribution systems.
  • Horizontal rear terminals support practical rear-connected switchboard layouts.
  • Part of ABB's established SACE Emax 2 air circuit breaker platform.

Key Features

  • ABB SACE Emax 2 E2.2S air circuit breaker.
  • 250 A rated current.
  • Three-pole configuration.
  • Fixed installation.
  • Horizontal rear terminals.
  • Ekip Dip LSI electronic trip unit.
  • L, S and I protection functions.
  • 690 V AC rated operational voltage.
  • 85 kA Icu at 380–440 V AC.
  • 66 kA Icw for 1 s for robust short-time fault withstand capability.

Selective LSI Protection for Low-Voltage Distribution

The Ekip Dip LSI electronic release provides three complementary protection functions for power distribution circuits. Long-time protection responds to sustained overloads, short-time protection provides controlled response to short-circuit currents and supports selective coordination, while instantaneous protection provides rapid tripping when very high fault currents occur.

The E2.2S performance level provides an ultimate short-circuit breaking capacity of 85 kA at 400 / 415 V AC together with a rated short-time withstand current of 66 kA for 1 s. Combined with fixed mounting and horizontal rear terminals, ABB 1SDA073629R1 is well suited to switchboards requiring high breaking performance and adjustable LSI protection.

Typical Applications

  • Low-voltage main and sub-distribution switchboards.
  • Industrial three-phase power distribution systems.
  • Manufacturing and process plant electrical distribution.
  • Commercial building power distribution.
  • Infrastructure and utility low-voltage switchgear.
  • Distribution systems requiring selective short-circuit coordination and adjustable electronic protection.

Technical Specifications

Series SACE Emax 2 E2.2
ABB order code 1SDA073629R1
Product type Air circuit breaker
Frame / performance level E2.2S
Rated current 250 A
Rated operational voltage (Ue) 690 V AC
Rated insulation voltage (Ui) 1000 V AC
Frequency 50 / 60 Hz
Ultimate short-circuit breaking capacity (Icu) at 380 V AC 85 kA
Ultimate short-circuit breaking capacity (Icu) at 400 / 415 V AC 85 kA
Ultimate short-circuit breaking capacity (Icu) at 440 V AC 85 kA
Ultimate short-circuit breaking capacity (Icu) at 500 / 525 V AC 66 kA
Ultimate short-circuit breaking capacity (Icu) at 690 V AC 66 kA
Rated short-time withstand current (Icw), 1 s 66 kA
Trip unit Ekip Dip LSI
Protection functions Long-time (L), short-time (S), instantaneous (I)
Overload protection adjustment 0.4–1 × In
Instantaneous protection adjustment 1.5–15 × In
Trip-unit adjustment method DIP switches
Number of poles 3
Installation Fixed
Terminal arrangement Horizontal rear terminals
Standard IEC 60947-2

Frequently Asked Questions

What is the ABB 1SDA073629R1?

The ABB 1SDA073629R1 is an E2.2S 250 Ekip Dip LSI three-pole fixed SACE Emax 2 air circuit breaker with horizontal rear terminals and a rated current of 250 A.

What protection functions does the Ekip Dip LSI trip unit provide?

The Ekip Dip LSI trip unit provides long-time overload (L), short-time short-circuit (S) and instantaneous short-circuit (I) protection.

What is the breaking capacity of the ABB E2.2S 250?

The breaker has an ultimate short-circuit breaking capacity of 85 kA at 380–440 V AC and 66 kA at 500–690 V AC.

What is the difference between Ekip Dip LI and Ekip Dip LSI?

Ekip Dip LI provides long-time and instantaneous protection, while Ekip Dip LSI adds short-time selective protection, providing an additional protection stage for improved coordination within power distribution systems.

What does FHR mean on the ABB E2.2S 250?

FHR identifies this configuration as a fixed circuit breaker with horizontal rear terminals, providing rear-facing connections for integration into compatible switchboard assemblies.

What voltage is the ABB 1SDA073629R1 rated for?

The circuit breaker has a rated operational voltage of 690 V AC and a rated insulation voltage of 1000 V AC.