1SDA073548R1 ABB E6.2X/MS 4000 4p WMP Switch-Disconnector

1SDA073548R1 ABB E6.2X/MS 4000 4p WMP Switch-Disconnector

ABB 1SDA073548R1 E6.2X/MS 4000 4p WMP is a four-pole 4000 A SACE Emax 2 withdrawable air switch-disconnector moving part with a maximum operational voltage of 690 V AC and 120 kA 1-second short-time withstand capability for demanding low-voltage power distribution systems.

SKU: 1SDA073548R1MPN: 1SDA073548R1
Price
List Price £27,577.85 ex VAT
Your Price (ex VAT) Save 25%
£20,683.39 25% OFF
You save £6,894.46 per unit
Manufacturer Lead Time Estimated Delivery 6 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £20,683.39
Trade pricing is personalised to your account

Manufacturer Lead Time

£20,683.39

Why Choose the ABB E6.2X/MS 4000 4p WMP Switch-Disconnector?

The ABB E6.2X/MS 4000 4p WMP, order code 1SDA073548R1, is a high-current four-pole withdrawable air switch-disconnector moving part from the ABB SACE Emax 2 range. Designed for demanding low-voltage power distribution systems, it provides a rated uninterrupted current of 4000 A and is suitable for operational voltages up to 690 V AC.

This E6.2X/MS configuration is the moving part of a withdrawable switch-disconnector, designed for installation with the corresponding Emax 2 fixed part. Its withdrawable architecture supports inspection, servicing and replacement in high-capacity switchboards, while the four-pole arrangement enables simultaneous switching and isolation of three phase conductors and the neutral.

With a rated short-time withstand current of 120 kA for 1 s, the E6.2X/MS 4000 delivers exceptional withstand capability for demanding distribution systems. Its combination of 4000 A current capacity, X performance level and four-pole withdrawable construction makes it particularly suitable for industrial and infrastructure installations with high prospective fault levels.

Key Advantages

  • Very high 4000 A rated uninterrupted current for major low-voltage distribution systems.
  • Exceptional 120 kA short-time withstand current for 1 s.
  • Four-pole configuration supports switching and isolation of three-phase systems with neutral.
  • Withdrawable moving-part design facilitates inspection, servicing and replacement.
  • Suitable for operational voltages up to 690 V AC.
  • 4000 A AC-21 and AC-23 operational current at 400 V.
  • X performance level provides higher short-time withstand capability than the corresponding E6.2H/MS configuration.
  • Part of ABB's established SACE Emax 2 high-current power distribution platform.

Key Features

  • ABB SACE Emax 2 E6.2X/MS series.
  • 4000 A rated uninterrupted current.
  • Four-pole switching configuration.
  • Maximum rated operational voltage of 690 V AC.
  • 120 kA rated short-time withstand current for 1 s.
  • Withdrawable moving part for use with the corresponding Emax 2 fixed part.
  • X performance level for demanding short-time withstand requirements.
  • Bolt connection for the main electrical circuit.
  • IP30 front-side protection.
  • Motor operator and voltage release available as optional equipment.

Reliable High-Current Withdrawable Switching and Isolation

The ABB E6.2X/MS provides a dependable means of switching and electrically isolating very high-current sections of low-voltage power distribution systems. Its withdrawable construction enables the moving part to be separated from the corresponding fixed part, supporting planned inspection, servicing and replacement while retaining the robust high-current architecture of the SACE Emax 2 platform.

With a 4000 A uninterrupted current rating and exceptional 120 kA for 1 s short-time withstand capability, the E6.2X/MS 4000 is engineered for substantial distribution loads and installations with demanding fault-withstand requirements. Its four-pole arrangement makes it particularly suitable for three-phase systems where the neutral conductor must also be switched and isolated.

Typical Applications

  • High-capacity low-voltage main distribution switchboards.
  • Industrial three-phase power distribution systems with neutral switching.
  • Large commercial and infrastructure electrical installations.
  • Switchboards requiring withdrawable high-current isolation devices.
  • Manufacturing, utilities and process plant power distribution systems.
  • Electrical assemblies requiring 4000 A switching with very high short-time withstand capability.

Technical Specifications

Series SACE Emax 2 E6.2
ABB order code 1SDA073548R1
EAN / GTIN 8015644773984
Product type Air switch-disconnector moving part
Frame / subtype E6.2X/MS
Performance level X
Rated uninterrupted current (Iu) 4000 A
Maximum rated operational voltage (Ue), AC 690 V
Rated short-time withstand current (Icw), 1 s 120 kA
Rated operational current, AC-21 at 400 V 4000 A
Rated operational current, AC-23 at 400 V 4000 A
Number of poles 4
Version Withdrawable moving part (WMP)
Main-circuit connection Bolt connection
Front-side protection rating IP30
Interlockable Yes
Motor operator Optional
Voltage release Optional
Power loss 544 W
Product net weight 134 kg
ABB product group Emax2 Air Circuit Breaker

Frequently Asked Questions

What is the ABB 1SDA073548R1 used for?

The ABB 1SDA073548R1 is a 4000 A four-pole withdrawable air switch-disconnector moving part designed for high-current switching and isolation duties in demanding low-voltage power distribution systems.

What is the rated current of the E6.2X/MS 4000 4p WMP?

The E6.2X/MS 4000 has a rated uninterrupted current of 4000 A.

What does WMP mean on the ABB E6.2X/MS 4000?

WMP identifies the moving part of the withdrawable configuration, designed for installation with the corresponding ABB SACE Emax 2 fixed part.

What is the short-time withstand current of the ABB 1SDA073548R1?

The E6.2X/MS 4000 has a rated short-time withstand current of 120 kA for 1 s.

What voltage is the E6.2X/MS 4000 designed for?

The ABB E6.2X/MS 4000 is designed for low-voltage applications with a maximum rated operational voltage of 690 V AC.

What is the difference between the E6.2X/MS and E6.2H/MS 4000 versions?

The E6.2X/MS provides a higher rated short-time withstand current of 120 kA for 1 s, compared with 100 kA for 1 s for the corresponding E6.2H/MS 4000 configuration.

Trusted by Power Distribution Professionals Worldwide

ABB SACE Emax 2 switch-disconnectors are engineered for demanding low-voltage power distribution systems where dependable isolation, very high current-carrying capability, robust short-time withstand performance and maintainable withdrawable construction are required.