1SDA073491R1 ABB E2.2H/MS 1250 3p WMP Switch Disconnector

1SDA073491R1 ABB E2.2H/MS 1250 3p WMP Switch Disconnector

ABB 1SDA073491R1 SACE Emax 2 E2.2H/MS 1250 three-pole withdrawable air switch disconnector moving part rated at 1250 A and 690 V AC with 85 kA one-second short-time withstand capability for dependable low-voltage switching and isolation.

SKU: 1SDA073491R1MPN: 1SDA073491R1
Price
List Price £6,158.75 ex VAT
Your Price (ex VAT) Save 25%
£4,619.06 25% OFF
You save £1,539.69 per unit
Manufacturer Lead Time Estimated Delivery 5 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £4,619.06
Trade pricing is personalised to your account

Manufacturer Lead Time

£4,619.06

Why Choose the ABB E2.2H/MS 1250 3p WMP Switch Disconnector?

The ABB E2.2H/MS 1250 3p WMP, order code 1SDA073491R1, is a high-performance three-pole withdrawable air switch disconnector from the ABB SACE Emax 2 family, designed for dependable switching and electrical isolation in demanding low-voltage power distribution systems. Based on the Emax 2 E2.2 platform, this H-performance model combines a 1250 A current rating with high short-time withstand capability for industrial, commercial and infrastructure switchboards.

The E2.2H/MS is designed as a switch disconnector in accordance with IEC 60947-3. Unlike an automatic air circuit breaker, the /MS version does not incorporate a protection trip unit and is intended primarily for switching and isolation. This product is the withdrawable moving part, allowing it to be disconnected from its compatible fixed part for inspection, servicing and maintenance.

With a rated uninterrupted current of 1250 A, a three-pole configuration and a rated short-time withstand current of 85 kA for 1 s, the E2.2H/MS is suited to demanding power distribution installations. Its 690 V AC rated operational voltage, 1000 V AC insulation voltage and AC-23A utilisation category provide a robust specification for high-current switching and isolation.

Key Advantages

  • High-performance 1250 A air switch disconnector for low-voltage distribution.
  • Three-pole configuration for three-phase switching and isolation.
  • 85 kA short-time withstand current for 1 s for demanding fault-level conditions.
  • 66 kA short-time withstand current for 3 s.
  • Withdrawable moving-part design supports efficient servicing and maintenance.
  • Built on the proven ABB SACE Emax 2 E2.2 platform.

Key Features

  • ABB SACE Emax 2 E2.2H/MS series.
  • 1250 A rated uninterrupted current.
  • 3-pole configuration.
  • 690 V AC rated operational voltage.
  • 1000 V AC rated insulation voltage.
  • 85 kA Icw for 1 s.
  • 66 kA Icw for 3 s.
  • AC-23A utilisation category.
  • Withdrawable moving-part construction.
  • Switch-disconnector design without an automatic protection trip unit.

Reliable Switching and Isolation for Power Distribution

ABB Emax 2 /MS switch disconnectors provide reliable switching and electrical isolation of low-voltage power circuits. When the device is open, the separation of the main contacts provides the isolation required for downstream equipment, while the absence of an automatic protection trip unit distinguishes the /MS configuration from an Emax 2 air circuit breaker.

The withdrawable E2.2H/MS architecture allows the moving part to be separated from its compatible fixed part, supporting maintenance and servicing without the limitations of a permanently fixed device. Combined with its 1250 A current rating and 85 kA one-second withstand capability, the 1SDA073491R1 is well suited to demanding low-voltage distribution assemblies.

Typical Applications

  • Main low-voltage distribution switchboards.
  • Industrial power distribution systems.
  • Commercial and infrastructure electrical installations.
  • Three-phase circuit isolation and sectionalising.
  • Withdrawable switchgear requiring service flexibility.
  • OEM switchgear and panel-building applications.

Technical Specifications

Series SACE Emax 2 E2.2
ABB order code 1SDA073491R1
Product type Air switch disconnector moving part
Rated uninterrupted current (Iu) 1250 A
Number of poles 3
Rated operational voltage (Ue) 690 V AC
Rated insulation voltage (Ui) 1000 V AC
Rated short-time withstand current (Icw), 1 s 85 kA
Rated short-time withstand current (Icw), 3 s 66 kA
Rated current, AC-21 at 400 V 1250 A
Rated current, AC-23 at 400 V 1250 A
Frequency 50 / 60 Hz
Utilisation category AC-23A
Performance level H
Installation Withdrawable
Device configuration Moving part
EAN 8015644773410
Standard IEC 60947-3

Frequently Asked Questions

What is the ABB 1SDA073491R1 used for?

The ABB 1SDA073491R1 is an Emax 2 E2.2H/MS withdrawable air switch disconnector moving part designed for switching and electrical isolation in demanding low-voltage power distribution systems.

What is the current rating of the ABB E2.2H/MS 1250?

The switch disconnector has a rated uninterrupted current of 1250 A.

What short-time current can the E2.2H/MS 1250 withstand?

The device has a rated short-time withstand current of 85 kA for 1 second and 66 kA for 3 seconds.

What voltage is the ABB 1SDA073491R1 rated for?

The switch disconnector has a rated operational voltage of 690 V AC and a rated insulation voltage of 1000 V AC.

Is the ABB E2.2H/MS 1250 fixed or withdrawable?

The 1SDA073491R1 is the withdrawable moving part of the switch disconnector and is designed for use with the appropriate Emax 2 fixed part.

Trusted ABB Power Distribution Technology

ABB SACE Emax 2 switch disconnectors combine robust construction, high short-time withstand performance and flexible withdrawable installation for dependable switching and isolation in demanding low-voltage power distribution systems.