1SDA073460R1 ABB E4.2N/MS 4000 4p FHR Switch Disconnector

1SDA073460R1 ABB E4.2N/MS 4000 4p FHR Switch Disconnector

ABB 1SDA073460R1 E4.2N/MS 4000 four-pole fixed air switch disconnector with a 4000 A rated current, 690 V AC operational voltage and 66 kA 1-second short-time withstand capability for high-current low-voltage power distribution and isolation.

SKU: 1SDA073460R1MPN: 1SDA073460R1
Price
List Price £23,329.12 ex VAT
Your Price (ex VAT) Save 25%
£17,496.84 25% OFF
You save £5,832.28 per unit
Manufacturer Lead Time Estimated Delivery 5 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £17,496.84
Trade pricing is personalised to your account

Manufacturer Lead Time

£17,496.84

Why Choose the ABB E4.2N/MS 4000 4p FHR Switch Disconnector?

The ABB E4.2N/MS 4000 4p FHR, order code 1SDA073460R1, is a high-current four-pole air switch disconnector from the ABB SACE Emax 2 range, designed for dependable switching and isolation in demanding low-voltage power distribution systems. Based on the E4.2 frame, this /MS version provides a substantial 4000 A rated uninterrupted current for major industrial, commercial and infrastructure electrical installations.

The E4.2N/MS performance level provides a rated short-time withstand current of 66 kA for 1 s, enabling the device to withstand high fault-current conditions while appropriately coordinated protective equipment provides automatic circuit protection. The /MS switch-disconnector configuration is designed to satisfy the isolation requirements of IEC 60947-3.

This model is supplied in a fixed four-pole configuration with horizontal rear terminals (FHR). With a rated operational voltage of 690 V AC, its high current capacity, robust Emax 2 construction and rear-connected arrangement make it particularly suitable for integration into high-power low-voltage switchboards.

Key Advantages

  • High-capacity 4000 A four-pole air switch disconnector.
  • 66 kA short-time withstand current for 1 s for demanding power distribution systems.
  • Four-pole switching enables simultaneous isolation of four conductors.
  • 690 V AC rated operational voltage suitable for industrial low-voltage networks.
  • Fixed E4.2 construction for permanent switchboard installation.
  • Horizontal rear terminals support efficient busbar and conductor connections.
  • Part of the proven ABB SACE Emax 2 power distribution platform.

Key Features

  • ABB SACE Emax 2 E4.2N/MS switch disconnector.
  • 4000 A rated uninterrupted current (Iu).
  • Four-pole configuration.
  • 66 kA rated short-time withstand current (Icw) for 1 s.
  • 690 V AC rated operational voltage.
  • Switch-disconnector designed to meet IEC 60947-3 isolation requirements.
  • Fixed installation configuration.
  • Horizontal rear terminals (FHR).
  • Robust E4.2 frame for high-current low-voltage distribution.
  • Suitable for main switching and isolation duties in electrical switchboards.

Reliable High-Current Isolation for Power Distribution

ABB Emax 2 /MS switch disconnectors are designed for controlled switching and electrical isolation rather than automatic overcurrent protection. They provide a clear means of isolating sections of a low-voltage installation while dedicated protective equipment within the electrical system provides the required overload and short-circuit protection.

With its 4000 A continuous current rating and 66 kA 1-second short-time withstand capability, the E4.2N/MS is engineered for substantial power distribution loads. Its fixed four-pole design and horizontal rear connections make it particularly suitable for high-current switchboards where robust performance, dependable isolation and efficient busbar integration are required.

Typical Applications

  • Main low-voltage distribution switchboards.
  • Industrial power distribution systems.
  • High-current incoming and outgoing isolation duties.
  • Transformer secondary distribution systems.
  • Generator and standby power installations.
  • Commercial and infrastructure electrical distribution.
  • Manufacturing and process plant switchgear.

Technical Specifications

Series SACE Emax 2
Order code 1SDA073460R1
EAN 8015644773106
Product type Air switch disconnector
Frame E4.2
Performance level N
Rated uninterrupted current (Iu) 4000 A
Number of poles 4
Rated operational voltage 690 V AC
Rated short-time withstand current (Icw), 1 s 66 kA
Installation Fixed
Terminal configuration Horizontal rear terminals (FHR)
Power loss 465 W
Isolation standard IEC 60947-3

Frequently Asked Questions

What is the ABB 1SDA073460R1 used for?

The ABB 1SDA073460R1 is an E4.2N/MS air switch disconnector designed for high-current switching and electrical isolation in low-voltage power distribution systems.

What is the current rating of the E4.2N/MS 4000?

The E4.2N/MS 4000 has a rated uninterrupted current of 4000 A.

What is the short-time withstand rating of this switch disconnector?

The E4.2N/MS 4000 has a rated short-time withstand current of 66 kA for 1 s.

How many poles does the ABB 1SDA073460R1 have?

The 1SDA073460R1 has a four-pole configuration, allowing four conductors to be switched and isolated together.

How is the ABB E4.2N/MS 4000 4p FHR installed?

This model is supplied in a fixed configuration with horizontal rear terminals, making it suitable for permanent integration into high-current low-voltage switchboards.

Trusted ABB Power Distribution Technology

ABB SACE Emax 2 switch disconnectors provide robust high-current switching and dependable electrical isolation for industrial, commercial and infrastructure power systems, with the E4.2N/MS platform engineered for demanding low-voltage distribution applications.