1SDA073451R1 ABB E2.2N/MS 2000 4p F HR Switch Disconnector

1SDA073451R1 ABB E2.2N/MS 2000 4p F HR Switch Disconnector

ABB 1SDA073451R1 SACE Emax 2 E2.2N/MS 2000 four-pole fixed switch disconnector with horizontal rear terminals, a 2000 A rated uninterrupted current, 690 V AC operational voltage and 66 kA short-time withstand capability for high-current low-voltage switching and isolation.

SKU: 1SDA073451R1MPN: 1SDA073451R1
Price
List Price £10,232.04 ex VAT
Your Price (ex VAT) Save 25%
£7,674.03 25% OFF
You save £2,558.01 per unit
Manufacturer Lead Time Estimated Delivery 5 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £7,674.03
Trade pricing is personalised to your account

Manufacturer Lead Time

£7,674.03

Why Choose the ABB E2.2N/MS 2000 4p F HR Switch Disconnector?

The ABB E2.2N/MS 2000 4p F HR, order code 1SDA073451R1, is a SACE Emax 2 switch disconnector designed for dependable switching and isolation in high-current low-voltage electrical distribution systems. Built on ABB's E2.2 platform, this fixed four-pole device provides a 2000 A rated uninterrupted current and is suited to industrial, commercial and infrastructure switchboards requiring robust four-pole isolation.

The E2.2N/MS configuration is derived from the Emax 2 circuit breaker platform but operates as a switch disconnector without an integral electronic protection trip unit. It is designed to make, carry and isolate circuits while overload and short-circuit protection is provided separately within the electrical installation. Its four-pole construction provides simultaneous switching and isolation of four conductors in suitable three-phase four-wire systems.

Rated for operation at up to 690 V AC, with a 1000 V AC insulation voltage and 12 kV impulse withstand voltage, the E2.2N/MS 2000 provides a rated short-time withstand current of 66 kA for 1 s and 50 kA for 3 s. Its fixed construction and horizontal rear terminals (HR) support efficient integration with high-current switchboard busbars.

Key Advantages

  • High 2000 A rated uninterrupted current for demanding low-voltage distribution systems.
  • Four-pole configuration for switching and isolation in suitable three-phase four-wire networks.
  • 66 kA short-time withstand current for 1 s for high fault-level installations.
  • 50 kA short-time withstand current for 3 s supports demanding coordination requirements.
  • Rated for operation at up to 690 V AC.
  • Horizontal rear terminals support efficient high-current busbar connections.
  • Fixed installation provides a robust and straightforward switchboard configuration.
  • Based on ABB's modular SACE Emax 2 platform with extensive accessory compatibility.

Key Features

  • ABB SACE Emax 2 E2.2N/MS switch disconnector.
  • 2000 A rated uninterrupted current.
  • Four-pole configuration with 100% neutral-pole current capability.
  • Fixed installation.
  • Horizontal rear terminals (HR).
  • 690 V AC rated operational voltage.
  • 1000 V AC rated insulation voltage.
  • 12 kV rated impulse withstand voltage.
  • 66 kA rated short-time withstand current for 1 s.
  • 50 kA rated short-time withstand current for 3 s.
  • 2000 A AC-21 switching current at 400 V AC.
  • 2000 A AC-23 switching current at 400 V AC.
  • Electrical durability of 10000 cycles at ≤440 V AC.
  • Electrical durability of 8000 cycles at 500–690 V AC.
  • Mechanical durability of 25000 cycles.

Four-Pole High-Current Switching and Isolation

Switch disconnectors provide a dependable means of making, carrying and isolating electrical circuits while dedicated protective devices elsewhere in the installation provide overload and short-circuit protection. Four-pole devices are particularly useful in suitable three-phase four-wire distribution systems where simultaneous switching and isolation of all four conductors is required.

The ABB E2.2N/MS 2000 combines a 2000 A continuous-current rating with a 66 kA short-time withstand capability for 1 s. Its fixed four-pole construction, 100% neutral-pole current capability and horizontal rear terminals make it well suited to main switchboards and high-current distribution systems requiring dependable isolation and efficient busbar integration.

Typical Applications

  • Main switchboard switching and isolation.
  • Three-phase four-wire low-voltage distribution systems.
  • Industrial power distribution switchboards.
  • High-current feeder switching and isolation.
  • Transformer secondary distribution systems.
  • Busbar and bus-section isolation.
  • Commercial buildings and critical infrastructure.
  • Manufacturing and process plant electrical systems.

Technical Specifications

Series SACE Emax 2
Order code / MPN 1SDA073451R1
EAN / GTIN 8015644773014
Product type Circuit-breaker switch disconnector
Product group Emax 2 Air Circuit Breaker
Frame E2.2
Performance level N/MS
Short-circuit performance level N
Rated current (In) 2000 A
Rated uninterrupted current (Iu) 2000 A
Number of poles 4
Neutral pole current 100% of Iu
Current type AC
Rated operational voltage (Ue) 690 V AC
Rated insulation voltage (Ui) 1000 V AC
Rated impulse withstand voltage (Uimp) 12 kV
Frequency 50/60 Hz
Rated short-time withstand current (Icw), 1 s 66 kA
Rated short-time withstand current (Icw), 3 s 50 kA
Rated current, AC-21 at 400 V 2000 A
Rated current, AC-23 at 400 V 2000 A
Utilisation category AC-23A
Electrical durability at Ue ≤ 440 V 10000 cycles
Electrical durability at Ue 500–690 V 8000 cycles
Electrical operating frequency 30 cycles per hour
Mechanical durability 25000 cycles
Mechanical operating frequency 60 cycles per hour
Power loss 212 W
Connecting capacity 1800 mm²
Main-circuit connection Bolted connection
Recommended connection hardware M12
Tightening torque 70 N·m
Installation Fixed
Terminal configuration Rear flat horizontal (HR)
Dimensions (W × H × D) 366 × 371 × 270 mm
Net weight 53 kg
Standard IEC 60947-3

Frequently Asked Questions

What is the ABB 1SDA073451R1?

The ABB 1SDA073451R1 is an Emax 2 E2.2N/MS 2000 four-pole circuit-breaker switch disconnector with fixed installation and horizontal rear terminals, designed for high-current low-voltage switching and isolation.

What is the rated current of the ABB E2.2N/MS 2000?

The E2.2N/MS 2000 has a rated uninterrupted current of 2000 A and a rated operational voltage of up to 690 V AC.

What is the short-time withstand current of the ABB 1SDA073451R1?

The E2.2N/MS 2000 has a rated short-time withstand current of 66 kA for 1 s and 50 kA for 3 s.

Is the ABB E2.2N/MS 2000 a circuit breaker or switch disconnector?

The 1SDA073451R1 is a circuit-breaker switch disconnector derived from the ABB SACE Emax 2 platform. It is designed for switching and isolation and does not incorporate the electronic protection trip unit used on protective Emax 2 air circuit breakers.

What does 4p F HR mean on the ABB E2.2N/MS 2000?

The 4p designation identifies a four-pole device, F identifies the fixed installation configuration and HR identifies the horizontal rear terminal arrangement.

Trusted High-Current Switching and Isolation from ABB

ABB SACE Emax 2 switch disconnectors combine dependable isolation, high short-time withstand performance and robust switchboard integration for demanding industrial, commercial and infrastructure low-voltage power distribution systems.