1SDA073450R1 ABB E2.2B/MS 2000 4p F HR Switch-Disconnector

1SDA073450R1 ABB E2.2B/MS 2000 4p F HR Switch-Disconnector

ABB 1SDA073450R1 E2.2B/MS 2000 4p F HR is a 2000 A four-pole fixed SACE Emax 2 air switch-disconnector with rear horizontal terminals, 690 V AC operational voltage and a 42 kA short-time withstand rating for dependable low-voltage switching and isolation.

SKU: 1SDA073450R1MPN: 1SDA073450R1
Price
List Price £9,725.34 ex VAT
Your Price (ex VAT) Save 25%
£7,294.01 25% OFF
You save £2,431.34 per unit
Manufacturer Lead Time Estimated Delivery 5 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £7,294.01
Trade pricing is personalised to your account

Manufacturer Lead Time

£7,294.01

Why Choose the ABB E2.2B/MS 2000 4p F HR Switch-Disconnector?

The ABB E2.2B/MS 2000 4p F HR, order code 1SDA073450R1, is a high-current four-pole fixed air switch-disconnector from the ABB SACE Emax 2 range. Rated at 2000 A, it is designed for dependable switching and isolation in low-voltage power distribution systems where substantial continuous-current capacity and four-pole circuit separation are required.

The E2.2B/MS is a switch-disconnector rather than an automatic circuit breaker fitted with an electronic protection release. It provides a rated short-time withstand current of 42 kA for 1 s and 42 kA for 3 s, enabling the device to withstand prospective fault current while appropriately coordinated protective devices provide automatic overload and short-circuit protection.

This version combines a fixed four-pole configuration with rear horizontal (HR) terminals for integration into high-current switchboards. With a rated operational voltage of 690 V AC, rated insulation voltage of 1000 V AC, 50/60 Hz frequency and an AC-23A utilisation category, the E2.2B/MS 2000 provides robust switching and isolation for industrial, commercial and infrastructure power distribution applications.

Key Advantages

  • High-current 2000 A four-pole switch-disconnector for low-voltage power distribution.
  • 42 kA short-time withstand current for 1 s for coordinated electrical systems.
  • 42 kA short-time withstand current for 3 s supports time-selective protection arrangements.
  • Four-pole construction enables switching and isolation across four conductors.
  • Rated for operation at up to 690 V AC.
  • 1000 V AC insulation voltage supports robust electrical isolation.
  • AC-23A utilisation category for demanding switching duties.
  • Provides switching and isolation without an integrated electronic overcurrent trip unit.
  • Fixed installation with rear horizontal terminals provides a robust high-current switchboard arrangement.
  • Optional motor operation provides flexibility for electrically controlled installations.
  • Part of the proven ABB SACE Emax 2 low-voltage switching platform.

Key Features

  • ABB SACE Emax 2 E2.2B/MS switch-disconnector.
  • 2000 A rated uninterrupted current.
  • Four-pole (4P) configuration.
  • Fixed (F) installation.
  • Rear horizontal (HR) main terminals.
  • 690 V AC rated operational voltage.
  • 1000 V AC rated insulation voltage.
  • 50/60 Hz rated frequency.
  • 42 kA rated short-time withstand current for 1 s.
  • 42 kA rated short-time withstand current for 3 s.
  • AC-23A utilisation category.
  • B short-time withstand performance level.
  • Switch-disconnector construction for switching and isolation duties.
  • No integrated electronic overcurrent protection release.
  • Bolt-type main-circuit connection.
  • Push-button operating element.
  • Lockable construction.
  • Optional motor drive.
  • Optional voltage release.
  • IP30 degree of protection at the front.
  • Designed in accordance with IEC 60947-3.

High-Current Four-Pole Switching and Isolation

The ABB Emax 2 E2.2B/MS is designed for installations requiring reliable high-current switching and four-pole circuit isolation without integrated automatic overcurrent protection. Its combination of a 2000 A continuous current rating, 690 V AC operational capability and 42 kA short-time withstand current makes it suitable for coordinated power distribution systems where separate protective devices provide automatic fault protection.

The fixed four-pole construction and rear horizontal terminals make the 1SDA073450R1 particularly suitable for integration into high-current low-voltage switchboards. Its AC-23A switching capability, optional motor drive and voltage release, and Emax 2 architecture provide a flexible solution for industrial facilities, infrastructure and critical electrical distribution systems.

Typical Applications

  • Main and secondary isolation in low-voltage switchboards.
  • Four-pole power distribution systems requiring neutral switching and isolation.
  • Industrial power distribution installations.
  • Bus-section and bus-coupler switching applications.
  • Transformer secondary distribution systems.
  • Manufacturing plants and process facilities.
  • Data centres and critical power infrastructure.
  • Large commercial and infrastructure electrical installations.
  • Utility and energy distribution systems.
  • Switchboards using separate upstream or downstream overcurrent protection.

Technical Specifications

Series SACE Emax 2
Product group Emax2 Air Circuit Breaker
Frame / type E2.2B/MS
Order code / MPN 1SDA073450R1
EAN / GTIN 8015644773007
Product type Air switch-disconnector
Rated uninterrupted current (Iu) 2000 A
Rated operational current, AC-21 at 400 V AC 2000 A
Number of poles 4P
Current type AC
Rated operational voltage (Ue) 690 V AC
Rated insulation voltage (Ui) 1000 V AC
Rated frequency 50/60 Hz
Rated short-time withstand current (Icw), 1 s 42 kA
Rated short-time withstand current (Icw), 3 s 42 kA
Utilisation category AC-23A
Performance level B
Protection release None – switch-disconnector configuration
Installation Fixed
Version F
Terminal connection Rear horizontal (HR)
Main-circuit connection Bolt connection
Operating element Push button
Lockable Yes
Optional motor drive Yes
Optional voltage release Yes
Front-side degree of protection IP30
Applicable standard IEC 60947-3

Frequently Asked Questions

What is the ABB 1SDA073450R1 used for?

The ABB 1SDA073450R1 is a 2000 A four-pole Emax 2 switch-disconnector designed for high-current switching and isolation duties in low-voltage electrical distribution systems.

Is the ABB E2.2B/MS 2000 a circuit breaker or a switch-disconnector?

The E2.2B/MS 2000 is a switch-disconnector. It provides switching and isolation without an integrated electronic protection release, so appropriately rated separate protective devices are required where automatic overload and short-circuit protection is needed.

What is the short-time withstand rating of the ABB 1SDA073450R1?

The E2.2B/MS 2000 has a rated short-time withstand current of 42 kA for 1 s and 42 kA for 3 s, supporting coordinated operation in low-voltage power distribution systems.

What does F HR mean in E2.2B/MS 2000 4p F HR?

F identifies the fixed installation version, while HR identifies the rear horizontal terminal arrangement. The 1SDA073450R1 is therefore a fixed E2.2 switch-disconnector with rear horizontal main terminals.

Can the ABB 1SDA073450R1 be motor operated?

Yes. The ABB 1SDA073450R1 supports an optional motor drive, allowing the switch-disconnector to be configured for electrically operated switching applications where required.

Trusted Switching and Isolation for High-Current Power Systems

ABB SACE Emax 2 switch-disconnectors combine high continuous-current capability, robust short-time withstand performance and flexible switching architecture for dependable isolation in industrial, commercial, infrastructure and critical low-voltage power distribution systems.