ABB 1SDA073426R1 SACE Emax 2 E6.2H/MS 5000 three-pole fixed circuit-breaker switch disconnector with horizontal rear terminals, a 5000 A rated uninterrupted current, 690 V AC operational voltage and 100 kA short-time withstand capability for high-current low-voltage switching and isolation.
£26,223.31
The ABB E6.2H/MS 5000 3p F HR, order code 1SDA073426R1, is a high-current SACE Emax 2 circuit-breaker switch disconnector designed for dependable switching and isolation in demanding low-voltage electrical distribution systems. Built on ABB's E6.2 platform, this fixed three-pole device provides a 5000 A rated uninterrupted current and is engineered for industrial, infrastructure and critical-power switchboards requiring robust high-current isolation.
The E6.2H/MS configuration is intended for switching and isolation rather than integral electronic overcurrent protection. It can make and carry substantial load currents while dedicated protective equipment elsewhere in the installation provides overload and short-circuit protection. Its H performance level provides a rated short-time withstand current of 100 kA, supporting use in electrical systems with very high prospective fault currents.
The 1SDA073426R1 is supplied in a fixed three-pole configuration with horizontal rear terminals (HR). Rated for operation at up to 690 V AC, with a 1000 V AC insulation voltage and 12 kV impulse withstand voltage, it combines high current-carrying capability with the robust mechanical construction of the ABB SACE Emax 2 range.
Switch disconnectors provide a dependable means of making, carrying and isolating electrical circuits while dedicated protective equipment elsewhere in the installation provides overload and short-circuit protection. In high-capacity low-voltage switchboards, devices based on air circuit breaker platforms offer the robust operating mechanism and short-time current withstand capability required for main isolation, busbar switching and high-current feeder duties.
The ABB E6.2H/MS 5000 combines a 5000 A continuous-current rating with a 100 kA short-time withstand capability for both 1 s and 3 s. Its fixed three-pole construction and horizontal rear terminals make it particularly suitable for switchboards requiring high-capacity rear busbar connections, dependable circuit isolation and strong short-time current withstand performance.
| Series | SACE Emax 2 |
|---|---|
| Order code / MPN | 1SDA073426R1 |
| EAN / GTIN | 8015644772765 |
| Product type | Circuit-breaker switch disconnector |
| Product group | Emax 2 Air Circuit Breaker |
| Frame | E6.2 |
| Performance level | H/MS |
| Short-circuit performance level | H |
| Rated current (In) | 5000 A |
| Rated uninterrupted current (Iu) | 5000 A |
| Number of poles | 3 |
| Current type | AC |
| Rated operational voltage (Ue) | 690 V AC |
| Rated voltage (Ur) | 690 V |
| Rated insulation voltage (Ui) | 1000 V AC |
| Rated impulse withstand voltage (Uimp) | 12 kV |
| Rated short-time withstand current (Icw), 1 s | 100 kA |
| Rated short-time withstand current (Icw), 3 s | 100 kA |
| Electrical durability at Ue ≤ 440 V | 3000 cycles |
| Electrical durability at Ue 500–690 V | 2000 cycles |
| Electrical operating frequency | 10 cycles per hour |
| Mechanical durability | 12000 cycles |
| Mechanical operating frequency | 60 cycles per hour |
| Power loss | 483 W |
| Main-circuit connection | Bolted connection |
| Recommended main-circuit hardware | M12 |
| Tightening torque | 70 N·m |
| Installation | Fixed |
| Terminal configuration | Rear flat horizontal (HR) |
| Dimensions (W × H × D) | 762 × 371 × 270 mm |
| Net weight | 109 kg |
| Standard | IEC |
The ABB 1SDA073426R1 is an Emax 2 E6.2H/MS 5000 three-pole circuit-breaker switch disconnector with fixed installation and horizontal rear terminals, designed for high-current low-voltage switching and isolation.
The E6.2H/MS 5000 has a rated uninterrupted current of 5000 A and a rated operational voltage of up to 690 V AC.
The E6.2H/MS 5000 provides a rated short-time withstand current (Icw) of 100 kA for 1 s and 100 kA for 3 s, supporting use in electrical systems with high prospective fault currents.
The 1SDA073426R1 is a circuit-breaker switch disconnector based on the ABB SACE Emax 2 platform. It is intended for high-current switching and isolation rather than providing the integral electronic overcurrent protection associated with Emax 2 air circuit breakers fitted with a trip unit.
The F designation identifies the fixed installation configuration, while HR identifies the horizontal rear terminal arrangement used for connection within the switchboard.
ABB SACE Emax 2 switch disconnectors combine very high continuous-current capability, strong short-time withstand performance and robust switchboard integration for demanding industrial, infrastructure and critical-power distribution systems.