1SDA073425R1 ABB E6.2X/MS 4000 3p F HR Switch Disconnector

1SDA073425R1 ABB E6.2X/MS 4000 3p F HR Switch Disconnector

ABB 1SDA073425R1 SACE Emax 2 E6.2X/MS 4000 three-pole fixed switch disconnector with horizontal rear terminals, a 4000 A rated uninterrupted current, 690 V AC operational voltage and 120 kA short-time withstand capability for high-current low-voltage switching and isolation.

SKU: 1SDA073425R1MPN: 1SDA073425R1
Price
List Price £18,671.09 ex VAT
Your Price (ex VAT) Save 25%
£14,003.32 25% OFF
You save £4,667.77 per unit
Manufacturer Lead Time Estimated Delivery 6 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £14,003.32
Trade pricing is personalised to your account

Manufacturer Lead Time

£14,003.32

Why Choose the ABB E6.2X/MS 4000 3p F HR Switch Disconnector?

The ABB E6.2X/MS 4000 3p F HR, order code 1SDA073425R1, is a high-performance SACE Emax 2 switch disconnector designed for switching and isolation in very high-current low-voltage electrical distribution systems. Built on ABB's E6.2 platform, this three-pole fixed device provides a 4000 A rated uninterrupted current and exceptionally high short-time withstand performance for demanding industrial, infrastructure and critical-power switchboards.

The E6.2X/MS configuration is a switch disconnector rather than a protective air circuit breaker fitted with an electronic trip unit. It is intended to make, carry and isolate high-current circuits while overcurrent and short-circuit protection is provided separately within the electrical system. The X performance level provides a rated short-time withstand current of 120 kA for 1 s, making this model suitable for installations with particularly high prospective fault currents.

The 1SDA073425R1 is supplied in a fixed three-pole configuration with horizontal rear terminals (HR). Rated for operation at up to 690 V AC, with a 1000 V AC insulation voltage and 12 kV impulse withstand voltage, it provides robust electrical and mechanical performance for high-capacity switchboards, main distribution assemblies and busbar systems.

Key Advantages

  • High 4000 A rated uninterrupted current for major low-voltage distribution systems.
  • 120 kA short-time withstand current for 1 s for very high fault-level installations.
  • 100 kA short-time withstand current for 3 s supports demanding distribution and coordination requirements.
  • Three-pole configuration for high-current three-phase switching and isolation.
  • Rated for operation at up to 690 V AC.
  • Horizontal rear terminals support direct and efficient switchboard busbar connections.
  • Fixed installation provides a robust solution for permanent high-current switchboard applications.
  • ABB SACE Emax 2 architecture provides high mechanical durability and extensive accessory compatibility.

Key Features

  • ABB SACE Emax 2 E6.2X/MS switch disconnector.
  • 4000 A rated uninterrupted current.
  • Three-pole configuration.
  • Fixed installation.
  • Horizontal rear terminals (HR).
  • 690 V AC rated operational voltage.
  • 1000 V AC rated insulation voltage.
  • 12 kV rated impulse withstand voltage.
  • 120 kA rated short-time withstand current for 1 s.
  • 100 kA rated short-time withstand current for 3 s.
  • Electrical durability of 4000 cycles at operating voltages up to 440 V AC.
  • Electrical durability of 4000 cycles at 500–690 V AC.
  • Mechanical durability of 12000 cycles.
  • High-capacity rear connection arrangement for switchboard integration.

High Fault-Level Switching and Isolation

Switch disconnectors provide a dependable means of making, carrying and isolating electrical circuits while dedicated protective equipment elsewhere in the installation provides overload and short-circuit protection. In large low-voltage distribution systems, the ability to withstand substantial short-circuit currents is particularly important for main switchboard, busbar and high-capacity feeder applications.

The ABB E6.2X/MS 4000 combines a 4000 A continuous-current rating with an exceptional 120 kA for 1 s short-time withstand capability and 100 kA for 3 s withstand rating. Its fixed three-pole construction and horizontal rear terminals make it well suited to high-capacity switchboards where robust busbar connections, dependable isolation and very high short-time current withstand performance are required.

Typical Applications

  • Main switching and isolation in high-capacity low-voltage switchboards.
  • Industrial power distribution systems with high prospective fault currents.
  • Transformer secondary switching and isolation.
  • High-current busbar and bus-section isolation.
  • Large manufacturing and process plant electrical systems.
  • Data centres and critical-power distribution infrastructure.
  • Utility, transport and major commercial electrical installations.

Technical Specifications

Series SACE Emax 2
Order code / MPN 1SDA073425R1
EAN / GTIN 8015644772758
Product type Switch disconnector
Product group Emax 2 Air Circuit Breaker
Frame E6.2
Performance level X/MS
Short-circuit performance level X
Rated current (In) 4000 A
Rated uninterrupted current (Iu) 4000 A
Number of poles 3
Current type AC
Rated operational voltage (Ue) 690 V AC
Rated voltage (Ur) 690 V
Rated insulation voltage (Ui) 1000 V AC
Rated impulse withstand voltage (Uimp) 12 kV
Rated short-time withstand current (Icw), 1 s 120 kA
Rated short-time withstand current (Icw), 3 s 100 kA
Electrical durability at Ue ≤ 440 V 4000 cycles
Electrical durability at Ue 500–690 V 4000 cycles
Electrical operating frequency 10 cycles per hour
Mechanical durability 12000 cycles
Mechanical operating frequency 60 cycles per hour
Power loss 309 W
Connecting capacity 4000 mm²
Recommended connection hardware M12
Installation Fixed
Terminal configuration Rear flat horizontal (HR)
Product net width 762 mm
Product net height 371 mm
Product net depth 270 mm
Net weight 109 kg
Standard IEC

Frequently Asked Questions

What is the ABB 1SDA073425R1?

The ABB 1SDA073425R1 is an Emax 2 E6.2X/MS 4000 three-pole switch disconnector with fixed installation and horizontal rear terminals, designed for high-current low-voltage switching and isolation.

What is the rated current of the ABB E6.2X/MS 4000?

The E6.2X/MS 4000 has a rated uninterrupted current of 4000 A and a rated operational voltage of up to 690 V AC.

What is the short-time withstand current of the ABB 1SDA073425R1?

The E6.2X/MS 4000 provides a rated short-time withstand current (Icw) of 120 kA for 1 s and 100 kA for 3 s, making it suitable for electrical systems with very high prospective fault currents.

Is the ABB E6.2X/MS 4000 a circuit breaker or switch disconnector?

The 1SDA073425R1 is a switch disconnector based on the ABB SACE Emax 2 platform. It is designed for switching and isolation and does not incorporate the electronic overcurrent protection trip unit used on protective Emax 2 air circuit breakers.

What does F HR mean on the ABB E6.2X/MS 4000?

The F designation identifies the fixed installation configuration, while HR identifies the horizontal rear terminal arrangement used for high-current connections within the switchboard.