1SDA073420R1 ABB E4.2V/MS 3200 3p F HR Switch-Disconnector

1SDA073420R1 ABB E4.2V/MS 3200 3p F HR Switch-Disconnector

ABB 1SDA073420R1 E4.2V/MS 3200 3p F HR is a 3200 A three-pole fixed SACE Emax 2 air switch-disconnector with rear horizontal terminals, 690 V AC operational voltage and a 100 kA one-second short-time withstand rating for demanding low-voltage switching and isolation applications.

SKU: 1SDA073420R1MPN: 1SDA073420R1
Price
List Price £13,740.21 ex VAT
Your Price (ex VAT) Save 25%
£10,305.16 25% OFF
You save £3,435.05 per unit
Manufacturer Lead Time Estimated Delivery 5 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £10,305.16
Trade pricing is personalised to your account

Manufacturer Lead Time

£10,305.16

Why Choose the ABB E4.2V/MS 3200 3p F HR Switch-Disconnector?

The ABB E4.2V/MS 3200 3p F HR, order code 1SDA073420R1, is a high-performance three-pole fixed air switch-disconnector from the ABB SACE Emax 2 range. Rated at 3200 A, it is engineered for dependable switching and isolation in demanding low-voltage power distribution systems where substantial continuous-current capability and very high short-time withstand performance are required.

The E4.2V/MS is a switch-disconnector rather than an automatic circuit breaker equipped with an electronic protection release. Its V-performance construction provides a rated short-time withstand current of 100 kA for 1 s and 75 kA for 3 s, enabling the device to withstand severe prospective fault currents while appropriately coordinated protective devices perform automatic fault interruption.

This version combines a fixed three-pole configuration with rear flat horizontal terminals for integration into high-current switchboards. With a rated operational voltage of 690 V AC, rated insulation voltage of 1000 V AC and rated impulse withstand voltage of 12 kV, the E4.2V/MS 3200 provides robust electrical isolation for industrial, infrastructure and critical power distribution applications.

Key Advantages

  • High-capacity 3200 A three-pole switch-disconnector for demanding low-voltage power distribution systems.
  • 100 kA short-time withstand current for 1 s supports installations with exceptionally high prospective fault levels.
  • 75 kA short-time withstand current for 3 s provides additional coordination capability.
  • Rated for operation at up to 690 V AC.
  • 1000 V AC insulation voltage and 12 kV impulse withstand voltage.
  • Provides dependable switching and isolation without an integrated overcurrent trip unit.
  • Fixed installation offers a robust configuration for permanent high-current switchboard connections.
  • Rear flat horizontal terminals support practical integration with high-current busbars.
  • Mechanical durability of 20,000 operating cycles.
  • Part of the proven ABB SACE Emax 2 low-voltage switching platform.

Key Features

  • ABB SACE Emax 2 E4.2V/MS switch-disconnector.
  • 3200 A rated uninterrupted current.
  • Three-pole (3P) configuration.
  • Fixed (F) installation.
  • Rear flat horizontal (HR) main terminals.
  • 690 V AC rated operational voltage.
  • 1000 V AC rated insulation voltage.
  • 12 kV rated impulse withstand voltage.
  • 100 kA rated short-time withstand current for 1 s.
  • 75 kA rated short-time withstand current for 3 s.
  • V short-circuit performance level.
  • Switch-disconnector construction for switching and isolation duties.
  • No integrated electronic overcurrent protection release.
  • Electrical durability of 7,000 cycles.
  • Mechanical durability of 20,000 cycles.
  • 3000 mm² connecting capacity.
  • Bolt-type main terminals with M12 connection hardware.
  • Designed in accordance with applicable IEC requirements.

Very High Short-Time Withstand Switching and Isolation

The ABB Emax 2 E4.2V/MS is designed for electrical installations requiring reliable high-current switching and circuit isolation without integrated automatic overcurrent protection. Its combination of a 3200 A continuous current rating, 690 V AC operational capability and short-time withstand ratings of 100 kA for 1 s and 75 kA for 3 s makes it particularly suitable for coordinated distribution systems with high prospective fault currents.

The fixed three-pole construction and rear flat horizontal terminals make the 1SDA073420R1 well suited to integration into high-current low-voltage switchboards and power distribution assemblies. With 20,000-cycle mechanical durability, 7,000-cycle electrical durability and the robust E4.2 Emax 2 architecture, it provides dependable switching and isolation for critical industrial and infrastructure applications.

Typical Applications

  • Main and secondary isolation in high-current low-voltage switchboards.
  • Industrial power distribution systems.
  • Bus-section and bus-coupler switching applications.
  • Transformer secondary distribution systems.
  • Manufacturing plants and process facilities.
  • Data centres and critical power infrastructure.
  • Large commercial and infrastructure electrical installations.
  • Utility and energy distribution systems.
  • Switchboards using separate upstream or downstream overcurrent protection.
  • High-fault-level systems requiring 100 kA one-second short-time withstand capability.

Technical Specifications

Series SACE Emax 2
Product group Emax2 Air Circuit Breaker
Frame / type E4.2V/MS
Order code / MPN 1SDA073420R1
EAN / GTIN 8015644772703
Product type Air switch-disconnector
Product main type SACE Emax 2
Sub-type E4.2
Rated current (In) 3200 A
Rated uninterrupted current (Iu) 3200 A
Number of poles 3P
Current type AC
Rated voltage (Ur) 690 V
Rated operational voltage (Ue) 690 V AC
Rated insulation voltage (Ui) 1000 V AC
Rated impulse withstand voltage (Uimp) 12 kV
Rated short-time withstand current (Icw), 1 s 100 kA
Rated short-time withstand current (Icw), 3 s 75 kA
Short-circuit performance level V
Protection release None – switch-disconnector configuration
Connecting capacity 3000 mm²
Electrical durability at Ue ≤ 440 V 7,000 cycles
Electrical durability at Ue 500–690 V 7,000 cycles
Electrical operating frequency 20 cycles per hour
Mechanical durability 20,000 cycles
Mechanical operating frequency 60 cycles per hour
Power loss 425 W
Installation Fixed
Version F
Terminal connection Rear flat horizontal (HR)
Terminal type Bolt
Recommended main-circuit screw M12
Standard IEC
Product net width 384 mm
Product net height 371 mm
Product net depth 270 mm
Product net weight 56 kg

Frequently Asked Questions

What is the ABB 1SDA073420R1 used for?

The ABB 1SDA073420R1 is a 3200 A three-pole Emax 2 switch-disconnector designed for high-current switching and isolation duties in demanding low-voltage electrical distribution systems.

Is the ABB E4.2V/MS 3200 a circuit breaker or a switch-disconnector?

The E4.2V/MS 3200 is a switch-disconnector. It provides switching and isolation without the electronic overcurrent protection release used on automatic Emax 2 circuit breakers, so appropriately coordinated protective devices are required where automatic fault protection is needed.

What is the short-time withstand rating of the ABB 1SDA073420R1?

The E4.2V/MS 3200 has a rated short-time withstand current of 100 kA for 1 s and 75 kA for 3 s, making it suitable for demanding systems with very high prospective fault currents.

What does F HR mean in E4.2V/MS 3200 3p F HR?

F identifies the fixed installation version, while HR refers to the rear horizontal terminal arrangement. This product uses rear flat horizontal bolt-type main terminals.

What are the dimensions of the ABB 1SDA073420R1?

The ABB 1SDA073420R1 measures approximately 384 mm wide, 371 mm high and 270 mm deep, with a product net weight of approximately 56 kg.

Trusted Switching and Isolation for High-Fault-Level Power Systems

ABB SACE Emax 2 switch-disconnectors combine high continuous-current capability, exceptional short-time withstand performance and robust switching architecture for dependable isolation in industrial, commercial, infrastructure and critical low-voltage power distribution systems.