1SDA073410R1 ABB E2.2H/MS 1600 3p FHR Switch Disconnector

1SDA073410R1 ABB E2.2H/MS 1600 3p FHR Switch Disconnector

ABB 1SDA073410R1 Emax 2 E2.2H/MS 1600 is a 1600 A three-pole fixed switch disconnector with rear horizontal terminals and an 85 kA short-time withstand current for 1 second.

SKU: 1SDA073410R1MPN: 1SDA073410R1
Price
List Price £6,217.22 ex VAT
Your Price (ex VAT) Save 25%
£4,662.92 25% OFF
You save £1,554.31 per unit
Manufacturer Lead Time Estimated Delivery 5 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £4,662.92
Trade pricing is personalised to your account

Manufacturer Lead Time

£4,662.92

Why Choose the ABB E2.2H/MS 1600 3p FHR Switch Disconnector?

The ABB E2.2H/MS 1600 3p FHR, order code 1SDA073410R1, is a fixed SACE Emax 2 switch disconnector designed for dependable high-current switching and isolation in demanding low-voltage power-distribution systems. Based on ABB's E2.2 frame, this three-pole unit combines a 1600 A rated uninterrupted current, H performance level and fixed installation with rear horizontal main-circuit terminals.

The E2.2H/MS is a switch-disconnector rather than an Emax 2 circuit breaker equipped with an Ekip electronic protection release. Its primary function is switching and isolation within a suitably protected electrical system, allowing feeders, busbar sections and other distribution circuits to be disconnected while associated protective devices provide the required overcurrent and short-circuit protection.

The H-performance configuration provides a substantial rated short-time withstand current of 85 kA for 1 s and 66 kA for 3 s. Combined with a rated operational voltage of 690 V AC, fixed construction and rear horizontal terminals, the 1SDA073410R1 provides a robust isolation solution for high-current industrial and infrastructure switchboards.

Key Advantages

  • High-current 1600 A Emax 2 switch disconnector for demanding low-voltage distribution systems.
  • Three-pole configuration for three-phase switching and isolation.
  • H performance level provides enhanced short-time current withstand capability.
  • 85 kA short-time withstand current for 1 s supports high-fault-level switchboard applications.
  • 66 kA short-time withstand current for 3 s supports coordinated distribution-system design.
  • Rear horizontal terminals provide a practical connection arrangement for switchboard busbars.
  • Fixed installation provides a robust permanent switching and isolation solution.

Key Features

  • ABB SACE Emax 2 E2.2H/MS series.
  • 1600 A rated uninterrupted current.
  • 3-pole configuration.
  • Switch-disconnector function.
  • H short-circuit performance level.
  • Fixed mounting version.
  • Rear flat horizontal main-circuit terminals.
  • Bolted main-circuit terminal construction.
  • Rated operational voltage: 690 V AC.
  • 85 kA rated short-time withstand current for 1 s.
  • 66 kA rated short-time withstand current for 3 s.
  • Designed for switching and isolation without an integral Ekip electronic protection trip unit.

High-Performance Switching and Isolation for Power Distribution

Switch disconnectors provide a defined means of switching and isolating electrical circuits while operating alongside dedicated protective devices within the distribution system. The ABB E2.2H/MS 1600 combines a substantial 1600 A continuous-current rating with the robust SACE Emax 2 architecture, making it suitable for major switchboard positions where dependable high-current isolation is required without an integral electronic overcurrent trip unit.

Its H performance level provides an 85 kA short-time withstand current for 1 s and 66 kA for 3 s, enabling the switch disconnector to withstand substantial fault currents for the specified duration while the associated protective system clears the fault. Fixed construction and rear horizontal terminals further support integration into industrial and infrastructure switchboards with high-current busbar systems.

Typical Applications

  • Main and sectional isolation in high-current low-voltage switchboards.
  • Industrial power-distribution systems.
  • Transformer secondary distribution assemblies.
  • Manufacturing and process-industry switchboards.
  • Commercial and infrastructure electrical distribution.
  • Utility and critical-power distribution systems.
  • Generator and auxiliary power-distribution switchboards.
  • Three-phase feeders requiring fixed 1600 A switching and high short-time withstand capability.

Technical Specifications

Series SACE Emax 2 E2.2
ABB order code 1SDA073410R1
EAN 8015644772604
Product type Switch disconnector
Frame E2.2
Performance level H
Rated uninterrupted current (Iu) 1600 A
Number of poles 3
Current type AC
Installation Fixed
Version F
Terminal connection Rear flat horizontal
Terminal type Bolt
Main-circuit terminal size M12
Main-circuit tightening torque 70 N·m
Rated operational voltage (Ue) 690 V AC
Rated short-time withstand current (Icw), 1 s 85 kA
Rated short-time withstand current (Icw), 3 s 66 kA
Power loss 136 W
Dimensions (W × H × D) 276 × 371 × 270 mm
Net weight 41 kg
Country of origin Italy
Integral electronic trip unit No
Applicable standard IEC

Frequently Asked Questions

What is the ABB 1SDA073410R1?

The ABB 1SDA073410R1 is a SACE Emax 2 E2.2H/MS fixed three-pole switch disconnector rated at 1600 A and equipped with rear horizontal main-circuit terminals.

Is the ABB E2.2H/MS 1600 a circuit breaker or switch disconnector?

It is a switch disconnector. The E2.2H/MS configuration is intended primarily for switching and isolation rather than providing the integral electronic overcurrent protection associated with Emax 2 circuit breakers fitted with Ekip trip units.

What is the short-time withstand current of the ABB 1SDA073410R1?

The E2.2H/MS 1600 has a rated short-time withstand current of 85 kA for 1 s and 66 kA for 3 s.

What does FHR mean on the ABB E2.2H/MS 1600?

The configuration denotes a fixed Emax 2 switch disconnector with rear horizontal terminals, providing a rear-facing connection arrangement suitable for integration with switchboard busbars.

Is the ABB 1SDA073410R1 fixed or withdrawable?

The 1SDA073410R1 is a fixed-mounting switch disconnector intended for permanent installation within the switchboard rather than use as a withdrawable moving part.

Trusted Switching and Isolation for High-Current Distribution

ABB SACE Emax 2 switch disconnectors combine robust high-current switching, substantial short-time current withstand and practical switchboard connection arrangements to provide dependable isolation for demanding low-voltage power-distribution systems.