ABB 1SDA073409R1 Emax 2 E2.2N/MS 1600 is a 1600 A three-pole fixed switch disconnector with adjustable rear horizontal terminals and a 66 kA short-time withstand current for 1 second.

SKU: 1SDA073409R1MPN: 1SDA073409R1
Price
List Price £5,574.05 ex VAT
Your Price (ex VAT) Save 25%
£4,180.54 25% OFF
You save £1,393.51 per unit
Manufacturer Lead Time Estimated Delivery 5 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £4,180.54
Trade pricing is personalised to your account

Manufacturer Lead Time

£4,180.54

Why Choose the ABB E2.2N/MS 1600 3p FHR Switch Disconnector?

The ABB E2.2N/MS 1600 3p FHR, order code 1SDA073409R1, is a fixed SACE Emax 2 switch disconnector designed for dependable switching and isolation in demanding low-voltage power-distribution systems. Based on ABB's E2.2 frame, this three-pole unit combines a 1600 A rated uninterrupted current, N performance level and fixed installation for industrial, infrastructure and commercial switchboards.

The E2.2N/MS is a switch-disconnector rather than an Emax 2 circuit breaker equipped with an Ekip electronic protection release. It is therefore intended primarily to provide switching and isolation within a suitably protected electrical system, allowing circuits or sections of a switchboard to be positively disconnected while associated protective devices provide the required overcurrent and short-circuit protection.

A key characteristic of this N-performance configuration is its 66 kA rated short-time withstand current for 1 s. The 1SDA073409R1 is a fixed three-pole version with adjustable rear horizontal terminals (FHR), providing a practical connection arrangement for integration into high-current low-voltage switchboards.

Key Advantages

  • High-current 1600 A Emax 2 switch disconnector for major low-voltage distribution systems.
  • Three-pole configuration for three-phase switching and isolation.
  • 66 kA short-time withstand current for 1 s supports demanding high-fault-level installations.
  • Fixed installation provides a robust permanent switchboard arrangement.
  • Adjustable rear horizontal terminals provide flexible rear busbar and conductor connection.
  • Suitable for applications at up to 690 V AC.
  • Part of ABB's established SACE Emax 2 low-voltage switching platform.

Key Features

  • ABB SACE Emax 2 E2.2N/MS series.
  • 1600 A rated uninterrupted current.
  • 3-pole configuration.
  • Switch-disconnector function.
  • N performance level.
  • Fixed mounting version.
  • FHR adjustable rear horizontal terminals.
  • 66 kA rated short-time withstand current for 1 s.
  • Suitable for fixed applications up to 690 V AC.
  • Designed for switching and isolation without an integral Ekip electronic protection trip unit.
  • E2.2 frame suitable for high-current power-distribution assemblies.
  • Designed for integration into ABB Emax 2 low-voltage switchboard architectures.

Reliable High-Current Switching and Isolation

Switch disconnectors provide a defined means of switching and isolating electrical circuits while working alongside dedicated protective devices within the distribution system. The ABB E2.2N/MS 1600 combines a substantial 1600 A continuous-current rating with the robust construction of the SACE Emax 2 platform, making it suitable for major switchboard positions where dependable isolation is required without an integral electronic overcurrent trip unit.

Its 66 kA short-time withstand current for 1 s enables the switch disconnector to withstand substantial prospective fault current for the specified duration while the associated protection system clears the fault. Combined with fixed mounting and adjustable rear horizontal terminals, the 1SDA073409R1 provides a practical solution for high-current industrial and infrastructure distribution assemblies.

Typical Applications

  • Main and sectional isolation in high-current low-voltage switchboards.
  • Industrial power-distribution systems.
  • Transformer secondary distribution assemblies.
  • Manufacturing and process-industry switchboards.
  • Commercial building electrical distribution.
  • Infrastructure and utility distribution systems.
  • Generator and auxiliary power-distribution switchboards.
  • Three-phase feeders requiring fixed 1600 A switching and isolation.

Technical Specifications

Series SACE Emax 2 E2.2
ABB order code 1SDA073409R1
EAN 8015644772598
Product type Switch disconnector
Frame E2.2
Performance level N
Rated uninterrupted current (Iu) 1600 A
Number of poles 3
Current type AC
Installation Fixed
Terminal arrangement Adjustable rear horizontal (FHR)
Maximum rated operational voltage (Ue) 690 V AC
Rated short-time withstand current (Icw), 1 s 66 kA
Width 276 mm
Height 371 mm
Depth 270 mm
Product weight 41 kg
Integral electronic trip unit No
Mounting arrangement Fixed switchboard installation

Frequently Asked Questions

What is the ABB 1SDA073409R1?

The ABB 1SDA073409R1 is a SACE Emax 2 E2.2N/MS fixed three-pole switch disconnector rated at 1600 A and equipped with adjustable rear horizontal terminals.

Is the ABB E2.2N/MS 1600 a circuit breaker or switch disconnector?

It is a switch disconnector. The E2.2N/MS configuration is intended for switching and isolation rather than providing the integral electronic overcurrent protection associated with Emax 2 circuit breakers fitted with Ekip trip units.

What is the short-time withstand current of the ABB 1SDA073409R1?

The E2.2N/MS 1600 has a rated short-time withstand current of 66 kA for 1 s, supporting use in demanding high-current distribution systems.

What does FHR mean on the ABB E2.2N/MS 1600?

The FHR configuration identifies a fixed Emax 2 unit with adjustable rear horizontal terminals, providing a rear connection arrangement for integration with switchboard busbars and conductors.

Is the ABB 1SDA073409R1 fixed or withdrawable?

The 1SDA073409R1 is a fixed-mounting switch disconnector. It is intended for permanent installation within the switchboard rather than use as a withdrawable moving part.

Trusted Switching and Isolation for High-Current Distribution

ABB SACE Emax 2 switch disconnectors combine robust high-current switching, substantial short-time current withstand and flexible switchboard connection options to provide dependable isolation for demanding low-voltage power-distribution systems.