1SDA073406R1 ABB E2.2N/MS 1250 3p FHR Switch-Disconnector 1250 A

1SDA073406R1 ABB E2.2N/MS 1250 3p FHR Switch-Disconnector 1250 A

ABB 1SDA073406R1 E2.2N/MS 1250 3p FHR is a 1250 A three-pole fixed SACE Emax 2 switch-disconnector with rear horizontal terminals, 690 V AC operational capability and 66 kA short-time withstand current for 1 s.

SKU: 1SDA073406R1MPN: 1SDA073406R1
Price
List Price £5,359.67 ex VAT
Your Price (ex VAT) Save 25%
£4,019.75 25% OFF
You save £1,339.92 per unit
Manufacturer Lead Time Estimated Delivery 5 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £4,019.75
Trade pricing is personalised to your account

Manufacturer Lead Time

£4,019.75

Why Choose the ABB E2.2N/MS 1250 3p FHR Switch-Disconnector?

The ABB E2.2N/MS 1250 3p FHR, order code 1SDA073406R1, is a high-performance three-pole switch-disconnector from the ABB SACE Emax 2 range, designed for switching and isolation duties in low-voltage power distribution systems. With a rated uninterrupted current of 1250 A, it combines the E2.2 frame with the N/MS performance level for industrial, commercial and infrastructure applications.

Unlike an Emax 2 circuit breaker fitted with an electronic protection release, the E2.2N/MS is a switch-disconnector configuration intended primarily for controlled switching and electrical isolation. It is particularly suitable where overcurrent and short-circuit protection is provided by other coordinated protective devices while a robust high-current disconnection point is required within the switchboard.

This version is supplied in a fixed three-pole configuration with rear horizontal terminals. It is rated for operation up to 690 V AC and provides a rated short-time withstand current of 66 kA for 1 s and 50 kA for 3 s, supporting demanding low-voltage distribution applications with high prospective fault currents.

Key Advantages

  • High-current 1250 A three-pole switch-disconnector for low-voltage power distribution.
  • Part of the proven ABB SACE Emax 2 E2.2 platform.
  • 66 kA short-time withstand current for 1 s for demanding electrical networks.
  • Rated for operation up to 690 V AC.
  • Fixed construction provides a robust solution for permanent switchboard installations.
  • Rear horizontal terminals support practical integration into compatible distribution assemblies.

Key Features

  • ABB SACE Emax 2 E2.2 platform.
  • 1250 A rated uninterrupted current.
  • Three-pole configuration.
  • N/MS performance level.
  • Switch-disconnector configuration for switching and isolation duties.
  • 690 V AC rated operational voltage.
  • 1000 V AC rated insulation voltage.
  • 12 kV rated impulse withstand voltage.
  • 66 kA Icw for 1 s.
  • 50 kA Icw for 3 s.
  • Fixed installation version.
  • Rear flat horizontal main terminals.
  • Optional motor operator and voltage release capability.
  • Interlockable construction for switchgear applications.

High-Current Switching and Isolation for Power Distribution

Switch-disconnectors provide controlled switching and electrical isolation within low-voltage distribution systems. In an Emax 2 MS configuration, the device provides the switching and isolation functions of the Emax 2 platform without the electronic overcurrent protection release normally associated with an air circuit breaker, allowing protection to be coordinated through other devices in the installation.

The E2.2N/MS 1250 combines a 1250 A continuous current rating with a 66 kA short-time withstand capability for 1 s and operation up to 690 V AC. Its fixed construction and rear horizontal terminals make it well suited to main switchboards and high-current distribution assemblies requiring a dependable three-pole switching and isolation device.

Typical Applications

  • Low-voltage main distribution switchboards.
  • Industrial power distribution systems.
  • High-current switching and isolation applications.
  • Commercial and infrastructure electrical installations.
  • Transformer and generator distribution systems.
  • Switchgear assemblies where overcurrent protection is provided by separate protective devices.
  • Incoming and outgoing distribution circuits requiring a fixed isolation device.

Technical Specifications

Series SACE Emax 2
Order code / MPN 1SDA073406R1
EAN 8015644772567
Product type Switch-disconnector
Frame / sub-type E2.2
Performance level N/MS
Rated current (In) 1250 A
Rated uninterrupted current (Iu) 1250 A
Number of poles 3
Rated operational voltage (Ue) 690 V AC
Rated insulation voltage (Ui) 1000 V AC
Rated impulse withstand voltage (Uimp) 12 kV
Rated short-time withstand current (Icw) 66 kA for 1 s
Rated short-time withstand current (Icw), 3 s 50 kA
Rated permanent current at AC-21, 400 V 1250 A
Rated permanent current at AC-23, 400 V 1250 A
Current type AC
Version Fixed
Main terminal arrangement Rear flat horizontal
Main circuit connection Bolted connection
Connecting capacity 1200 mm²
Front degree of protection IP30
Motor drive Optional
Voltage release Optional
Interlockable Yes
Electrical durability 15000 cycles
Mechanical durability 25000 cycles
Power loss 83 W
Dimensions (W × H × D) 276 × 371 × 270 mm
Net weight 41 kg
Standard IEC

Frequently Asked Questions

What is the ABB 1SDA073406R1 used for?

The ABB 1SDA073406R1 is a 1250 A three-pole switch-disconnector designed for high-current switching and electrical isolation in low-voltage power distribution systems.

Is the ABB E2.2N/MS 1250 an air circuit breaker?

The product belongs to the ABB SACE Emax 2 platform, but the MS designation identifies a switch-disconnector configuration. It is intended primarily for switching and isolation rather than providing the electronic overcurrent protection functions of an Emax 2 circuit breaker equipped with a trip unit.

What is the current rating of the ABB 1SDA073406R1?

The E2.2N/MS 1250 has a rated uninterrupted current of 1250 A and is configured with three poles for three-phase low-voltage power systems.

What is the short-time withstand current of the E2.2N/MS 1250?

The E2.2N/MS 1250 has a rated short-time withstand current of 66 kA for 1 s and 50 kA for 3 s, supporting demanding power distribution applications with high prospective fault currents.

Is the ABB 1SDA073406R1 fixed or withdrawable?

The ABB 1SDA073406R1 is a fixed three-pole switch-disconnector with rear horizontal terminals for integration into compatible low-voltage switchgear assemblies.

Trusted ABB Switching and Isolation for Power Systems

ABB SACE Emax 2 switch-disconnectors provide dependable high-current switching and isolation for demanding low-voltage power distribution systems, combining robust construction, high short-time withstand capability and the flexibility of the Emax 2 platform.