Standard delivery
£8 ex VAT · free over £200UK parcel delivery is £8 ex VAT, or free on orders over £200 ex VAT.
Heavier items may be charged at a weight-based or pallet rate, shown at checkout.
ABB 1SDA073371R1 SACE Emax 2 E6.2V/f 6300 Ekip Dip LI four-pole withdrawable air circuit breaker moving part with a 6300 A rated uninterrupted current, up to 150 kA breaking capacity and electronic LI protection for high-current low-voltage power distribution.
£53,776.80
The ABB E6.2V/f 6300 Ekip Dip LI 4p WMP, order code 1SDA073371R1, is a high-performance SACE Emax 2 air circuit breaker (ACB) designed for protection and control of high-current low-voltage electrical distribution systems. This four-pole E6.2 breaker combines a 6300 A rated uninterrupted current with ABB's Ekip Dip LI electronic release, providing dependable overload and instantaneous short-circuit protection for demanding power distribution applications.
The Ekip Dip LI electronic trip unit provides long-time overload (L) and instantaneous short-circuit (I) protection. Its straightforward electronic protection architecture makes the breaker well suited to installations requiring reliable high-current circuit protection without the additional selective short-circuit or earth-fault functions associated with LSI and LSIG releases.
The E6.2V/f 6300 delivers an ultimate short-circuit breaking capacity of 150 kA at 400–440 V AC, 130 kA at 500–525 V AC and 100 kA at 690 V AC. Supplied as a withdrawable moving part (WMP), it features a four-pole full-size neutral configuration and is designed for installation with a compatible ABB Emax 2 fixed part.
Air circuit breakers are used at critical points in low-voltage distribution systems where very high continuous currents and prospective short-circuit currents must be controlled safely. The ABB E6.2V/f 6300 combines a 6300 A current rating with breaking capacity reaching 150 kA, making it particularly suitable for major incomers, transformer secondary circuits, busbar systems and other high-capacity distribution duties.
The Ekip Dip LI release provides long-time overload and instantaneous short-circuit protection, helping protect conductors, switchgear and connected equipment against sustained overcurrents and severe short-circuit faults. Its withdrawable design also allows the breaker moving part to be isolated and removed from its compatible fixed part, supporting maintenance strategies for large industrial and infrastructure switchboards.
| Series | SACE Emax 2 |
|---|---|
| Order code / MPN | 1SDA073371R1 |
| EAN | 8015644772215 |
| Product type | Air circuit breaker |
| Product group | Emax 2 Air Circuit Breaker |
| Frame | E6.2 |
| Short-circuit performance level | V |
| Rated uninterrupted current (Iu) | 6300 A |
| Number of poles | 4 |
| Neutral configuration | Full-size neutral |
| Trip unit | Ekip Dip LI |
| Release type | Electronic / solid-state |
| Protection functions | L, I |
| Overload release adjustment range | 2520–6300 A |
| Current type | AC |
| Rated voltage | 690 V AC |
| Ultimate short-circuit breaking capacity (Icu) at 400 V AC | 150 kA |
| Ultimate short-circuit breaking capacity (Icu) at 415 V AC | 150 kA |
| Ultimate short-circuit breaking capacity (Icu) at 440 V AC | 150 kA |
| Ultimate short-circuit breaking capacity (Icu) at 500 V AC | 130 kA |
| Ultimate short-circuit breaking capacity (Icu) at 525 V AC | 130 kA |
| Ultimate short-circuit breaking capacity (Icu) at 690 V AC | 100 kA |
| Mechanical durability | 12000 cycles |
| Electrical durability at ≤440 V AC | 2000 cycles |
| Electrical durability at 500–690 V AC | 2000 cycles |
| Auxiliary contacts | 4 |
| Suitable for IT networks | Yes, up to 690 V |
| Installation | Withdrawable |
| Execution | Moving part (WMP) |
| Fixed part | Required separately for withdrawable installation |
| Dimensions (W × H × D) | 1069 × 425 × 383 mm |
| Net weight | 148 kg |
| Standard | IEC |
The ABB 1SDA073371R1 is an Emax 2 E6.2V/f 6300 air circuit breaker moving part with four poles, a full-size neutral and an Ekip Dip LI electronic release for high-current low-voltage electrical distribution systems.
The breaker has a rated uninterrupted current of 6300 A, making it suitable for very high-current low-voltage power distribution applications.
The Ekip Dip LI electronic trip unit provides long-time overload protection (L) and instantaneous short-circuit protection (I).
The E6.2V/f 6300 provides an ultimate short-circuit breaking capacity of 150 kA at 400/415/440 V AC, 130 kA at 500/525 V AC and 100 kA at 690 V AC.
The 1SDA073371R1 is a withdrawable moving part (WMP) designed for installation with a compatible ABB Emax 2 fixed part.
ABB SACE Emax 2 air circuit breakers combine high continuous-current capability, strong short-circuit performance and electronic protection for demanding industrial, commercial and infrastructure power distribution systems.