1SDA073363R1 ABB E6.2H/f 6300 Ekip Dip LSIG 4p WMP Air Circuit Breaker

1SDA073363R1 ABB E6.2H/f 6300 Ekip Dip LSIG 4p WMP Air Circuit Breaker

ABB 1SDA073363R1 is an Emax 2 E6.2H/f 6300 A four-pole full-size withdrawable air circuit breaker moving part with an Ekip Dip LSIG electronic trip unit for comprehensive very high-current low-voltage power distribution protection.

SKU: 1SDA073363R1MPN: 1SDA073363R1
Price
List Price £61,743.17 ex VAT
Your Price (ex VAT) Save 25%
£46,307.38 25% OFF
You save £15,435.79 per unit
Manufacturer Lead Time Estimated Delivery 6 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £46,307.38
Trade pricing is personalised to your account

Manufacturer Lead Time

£46,307.38

Why Choose the ABB E6.2H/f 6300 Ekip Dip LSIG 4p WMP Air Circuit Breaker?

The ABB E6.2H/f 6300 Ekip Dip LSIG 4p WMP, order code 1SDA073363R1, is a high-performance SACE Emax 2 air circuit breaker moving part designed for switching and protection of very high-current low-voltage electrical distribution systems. Part of the ABB Emax 2 E6.2H/f range, this four-pole breaker combines a 6300 A rated uninterrupted current with the Ekip Dip LSIG electronic protection release.

The integrated Ekip Dip LSIG trip unit provides long-time overload, short-time delayed short-circuit, instantaneous short-circuit and earth-fault protection. This comprehensive electronic protection package supports selective coordination while adding dedicated ground-fault protection for critical distribution circuits.

The E6.2H/f 6300 provides a rated ultimate short-circuit breaking capacity of 100 kA at 440 V AC and a rated short-time withstand current of 100 kA for 1 s. Its four-pole full-size withdrawable moving-part construction connects through the corresponding separate fixed part, supporting efficient servicing and replacement within high-current Emax 2 switchgear assemblies.

Key Advantages

  • Very high 6300 A rated uninterrupted current for major low-voltage distribution systems.
  • Four-pole full-size configuration for switching and protection of three-phase systems with neutral.
  • Ekip Dip LSIG electronic trip unit provides comprehensive overload, short-circuit and earth-fault protection.
  • 100 kA ultimate short-circuit breaking capacity at 440 V AC for demanding high-fault-level installations.
  • 100 kA short-time withstand current for 1 s supports selective protection strategies.
  • Integrated earth-fault protection helps protect distribution equipment against damaging ground-fault currents.
  • Withdrawable moving-part construction facilitates inspection, servicing and replacement.

Key Features

  • ABB SACE Emax 2 E6.2H/f series.
  • 6300 A rated uninterrupted current.
  • 4-pole full-size configuration.
  • Ekip Dip LSIG electronic protection release.
  • Long-time overload protection.
  • Short-time delayed short-circuit protection.
  • Instantaneous short-circuit protection.
  • Integrated earth-fault protection.
  • Rated voltage range up to 690 V AC.
  • 100 kA Icu at 440 V AC.
  • 100 kA Icw for 1 s.
  • Withdrawable moving-part (WMP) construction.
  • Main circuit connection through a separate fixed part.
  • 4 change-over auxiliary contacts.

Comprehensive LSIG Protection for 6300 A Power Distribution

Air circuit breakers such as the ABB Emax 2 E6.2H/f provide switching and protection for major low-voltage distribution circuits. By detecting overload, short-circuit and earth-fault conditions and interrupting the affected circuit, the breaker helps protect switchgear, conductors, transformers and other connected electrical equipment against potentially damaging fault currents.

The Ekip Dip LSIG electronic trip unit combines long-time overload protection with short-time delayed, instantaneous and earth-fault protection. Together with the 6300 A E6.2H/f breaker architecture, 100 kA short-circuit performance and withdrawable construction, it provides a robust solution for industrial switchboards and infrastructure systems requiring very high current capacity, selective protection and maintainable switchgear.

Typical Applications

  • Main incoming protection in very high-current low-voltage switchboards.
  • Industrial power-distribution systems.
  • Transformer secondary and main distribution protection.
  • Generator and power-plant distribution systems.
  • Large commercial and critical infrastructure installations.
  • High-fault-level switchgear and power distribution assemblies.

Technical Specifications

Series SACE Emax 2
ABB order code 1SDA073363R1
Product group Emax2 Air Circuit Breaker
Product type Air circuit breaker moving part
Frame / performance level E6.2H/f
Rated uninterrupted current (Iu) 6300 A
Number of poles 4
Configuration Full-size four-pole
Rated voltage range 220–690 V AC
Trip unit Ekip Dip LSIG
Trip unit type Electronic protection release
Protection functions Long-time, short-time, instantaneous and earth fault (LSIG)
Integrated earth-fault protection Yes
Rated ultimate short-circuit breaking capacity (Icu) at 440 V AC 100 kA
Rated short-time withstand current (Icw) 100 kA for 1 s
Installation Withdrawable
Construction Moving part
Configuration code WMP
Main circuit connection Through separate fixed part
Auxiliary change-over contacts 4
EAN 8015644772130

Frequently Asked Questions

What is the ABB 1SDA073363R1?

The ABB 1SDA073363R1 is an Emax 2 E6.2H/f 6300 four-pole full-size withdrawable air circuit breaker moving part equipped with an Ekip Dip LSIG electronic protection release.

What is the rated current of the ABB E6.2H/f 6300?

This air circuit breaker has a rated uninterrupted current of 6300 A, making it suitable for very high-current low-voltage power-distribution applications.

What protection functions does the Ekip Dip LSIG trip unit provide?

The LSIG configuration provides long-time overload, short-time delayed short-circuit, instantaneous short-circuit and earth-fault protection.

Does ABB 1SDA073363R1 include earth-fault protection?

Yes. The Ekip Dip LSIG release includes integrated earth-fault protection in addition to long-time, short-time and instantaneous protection.

What is the short-circuit performance of ABB 1SDA073363R1?

The E6.2H/f 6300 provides a rated ultimate short-circuit breaking capacity of 100 kA at 440 V AC and a rated short-time withstand current of 100 kA for 1 s.

Is the ABB 1SDA073363R1 fixed or withdrawable?

This model is a withdrawable moving part designed for installation with the corresponding separate ABB SACE Emax 2 fixed part, supporting efficient switchgear servicing and maintenance.

Trusted by Electrical Distribution Professionals Worldwide

ABB SACE Emax 2 air circuit breakers are designed for demanding industrial, infrastructure and power-distribution systems, combining very high current capacity, high short-circuit performance and advanced electronic protection for critical low-voltage applications.