1SDA073362R1 ABB E6.2H/f 6300 Ekip Dip LSI 4p WMP Air Circuit Breaker

1SDA073362R1 ABB E6.2H/f 6300 Ekip Dip LSI 4p WMP Air Circuit Breaker

ABB 1SDA073362R1 E6.2H/f 6300 Ekip Dip LSI 4p WMP is a 6300 A four-pole withdrawable Emax 2 air circuit breaker moving part with long-time, short-time and instantaneous electronic protection for very high-current low-voltage distribution systems.

SKU: 1SDA073362R1MPN: 1SDA073362R1
Price
List Price £61,005.86 ex VAT
Your Price (ex VAT) Save 25%
£45,754.40 25% OFF
You save £15,251.47 per unit
Manufacturer Lead Time Estimated Delivery 6 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £45,754.40
Trade pricing is personalised to your account

Manufacturer Lead Time

£45,754.40

Why Choose the ABB E6.2H/f 6300 Ekip Dip LSI 4p WMP Air Circuit Breaker?

The ABB E6.2H/f 6300 Ekip Dip LSI 4p WMP, order code 1SDA073362R1, is a high-capacity four-pole withdrawable air circuit breaker moving part from the ABB SACE Emax 2 range. Designed for demanding low-voltage power distribution systems, it combines a rated uninterrupted current of 6300 A with an Ekip Dip LSI electronic trip unit providing long-time overload, short-time selective short-circuit and instantaneous short-circuit protection.

The E6.2H/f full-size configuration is engineered for major switchboards where very high current capacity, dependable fault interruption and protection selectivity are essential. Its fully rated fourth pole makes it suitable for demanding four-pole distribution applications, while the withdrawable architecture enables the moving portion to be disconnected from the main circuit using the appropriate Emax 2 fixed part for inspection, maintenance or replacement.

With a rated uninterrupted current of 6300 A and an H-class rated ultimate short-circuit breaking capacity of 100 kA at 440 V AC, the E6.2H/f 6300 is designed for high-power electrical installations. Its rated short-time withstand current of 100 kA for 1 s supports selective protection strategies in complex industrial and infrastructure distribution networks.

Key Advantages

  • Very high-capacity 6300 A four-pole air circuit breaker for major low-voltage power distribution systems.
  • Ekip Dip LSI electronic trip unit provides long-time, short-time and instantaneous overcurrent protection.
  • 100 kA rated ultimate short-circuit breaking capacity at 440 V AC for demanding high-fault-level installations.
  • 100 kA short-time withstand current for 1 s supports selective protection and coordination.
  • Short-time protection provides greater coordination flexibility than an LI-only protection release.
  • Fully rated fourth pole supports demanding four-pole electrical distribution applications.
  • Withdrawable moving-part design supports efficient inspection, servicing and replacement.
  • Part of the proven ABB SACE Emax 2 air circuit breaker platform.

Key Features

  • ABB SACE Emax 2 E6.2H/f air circuit breaker.
  • 6300 A rated uninterrupted current.
  • Four-pole (4P) fully rated configuration.
  • Ekip Dip LSI electronic protection release.
  • Long-time (L) overload protection.
  • Short-time (S) selective short-circuit protection.
  • Instantaneous (I) short-circuit protection.
  • 100 kA rated ultimate short-circuit breaking capacity at 440 V AC.
  • 100 kA rated short-time withstand current for 1 s.
  • Rated voltage range of 220–690 V AC.
  • Main circuit connection through a separate fixed chassis part.
  • Withdrawable moving part (WMP) configuration.
  • Designed for high-current switchboards requiring selective fault protection.

Selective High-Current Protection for Critical Power Distribution

Air circuit breakers such as the ABB Emax 2 E6.2H/f provide switching, isolation and electrical protection for major low-voltage distribution systems. The combination of a 6300 A current rating, 100 kA short-circuit breaking capacity and 100 kA short-time withstand capability makes this breaker particularly suitable for main incomers, transformer secondary circuits, bus couplers and other high-current circuits in large switchboards.

The Ekip Dip LSI electronic release provides adjustable long-time protection against sustained overload conditions, short-time protection for selective coordination and instantaneous protection against severe short-circuit faults. Combined with the Emax 2 withdrawable architecture, the E6.2H/f 6300 provides a practical solution for installations requiring very high current capacity, dependable fault protection and maintainable switchgear.

Typical Applications

  • Main incomers in very high-current low-voltage switchboards.
  • Industrial power distribution systems.
  • Transformer secondary protection.
  • Bus couplers and bus-tie circuit breaker applications.
  • Data centres and critical power infrastructure.
  • Large commercial buildings and infrastructure facilities.
  • Manufacturing plants and process industries.
  • Utility and energy distribution systems.
  • High-current switchgear requiring selective short-circuit protection.
  • Critical distribution networks requiring coordinated upstream and downstream protection.

Technical Specifications

Series SACE Emax 2
Product group Emax2 Air Circuit Breaker
Frame / type E6.2H/f
Order code / MPN 1SDA073362R1
EAN / GTIN 8015644772123
Product type Air circuit breaker moving part
Construction Withdrawable
Rated uninterrupted current (Iu) 6300 A
Number of poles 4P
Fourth pole Fully rated
Current type AC
Trip unit Ekip Dip LSI
Release type Electronic
Protection functions L (long-time), S (short-time), I (instantaneous)
Rated voltage range 220–690 V AC
Rated ultimate short-circuit breaking capacity (Icu) at 400 V AC 100 kA
Rated ultimate short-circuit breaking capacity (Icu) at 440 V AC 100 kA
Rated service short-circuit breaking capacity (Ics) 100% of Icu
Rated short-time withstand current (Icw), 1 s 100 kA
Short-circuit performance level H
Integrated earth-fault protection No
Main circuit connection Connection via separate chassis part
Installation Withdrawable
Configuration Moving part (WMP)
Compatible fixed breaker E6.2H/f 6300 Ekip Dip LSI 4p fixed breaker, rear connection
Fixed breaker order code 1SDA072012R1

Frequently Asked Questions

What is the ABB 1SDA073362R1 used for?

The ABB 1SDA073362R1 is a 6300 A four-pole Emax 2 air circuit breaker moving part designed for protection, switching and isolation in very high-current low-voltage electrical distribution systems.

What protection functions does the Ekip Dip LSI trip unit provide?

The Ekip Dip LSI electronic trip unit provides long-time overload (L), short-time selective short-circuit (S) and instantaneous short-circuit (I) protection.

What is the breaking capacity of the ABB 1SDA073362R1?

The E6.2H/f 6300 has a rated ultimate short-circuit breaking capacity of 100 kA at 400 V AC and 440 V AC, with a rated service short-circuit breaking capacity equal to 100% of Icu.

Does the ABB 1SDA073362R1 include earth-fault protection?

No. The Ekip Dip LSI release provides long-time, short-time and instantaneous overcurrent protection. An LSIG-equipped Emax 2 version should be selected where integrated earth-fault protection is required.

Is the ABB 1SDA073362R1 a withdrawable circuit breaker?

Yes. The 1SDA073362R1 is the moving portion of a withdrawable ABB Emax 2 air circuit breaker and is designed for use with the appropriate compatible Emax 2 fixed part.

Trusted Protection for High-Current Power Systems

ABB SACE Emax 2 air circuit breakers combine very high current capability, dependable electronic protection, strong short-circuit performance and a maintainable withdrawable architecture for demanding industrial, commercial and critical low-voltage power distribution applications.