1SDA073348R1 ABB E6.2V/f 5000 Ekip Hi-Touch LSI 4p WMP Air Circuit Breaker

1SDA073348R1 ABB E6.2V/f 5000 Ekip Hi-Touch LSI 4p WMP Air Circuit Breaker

ABB 1SDA073348R1 Emax 2 E6.2V/f 5000 is a 5000 A four-pole full-size withdrawable air circuit breaker moving part with Ekip Hi-Touch LSI electronic protection, advanced monitoring and high short-circuit performance.

SKU: 1SDA073348R1MPN: 1SDA073348R1
Price
List Price £63,263.35 ex VAT
Your Price (ex VAT) Save 25%
£47,447.51 25% OFF
You save £15,815.84 per unit
Manufacturer Lead Time Estimated Delivery 6 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £47,447.51
Trade pricing is personalised to your account

Manufacturer Lead Time

£47,447.51

Why Choose the ABB E6.2V/f 5000 Ekip Hi-Touch LSI 4p WMP Air Circuit Breaker?

The ABB E6.2V/f 5000 Ekip Hi-Touch LSI 4p WMP, order code 1SDA073348R1, is a high-performance SACE Emax 2 withdrawable air circuit breaker moving part designed for protection, switching and advanced monitoring in demanding low-voltage power-distribution systems. Part of the ABB Emax 2 E6.2 full-size range, this four-pole breaker combines a 5000 A rated uninterrupted current, V-level short-circuit performance and an advanced Ekip Hi-Touch LSI electronic protection release.

The integrated Ekip Hi-Touch LSI trip unit provides long-time overload (L), selective short-time short-circuit (S) and instantaneous short-circuit (I) protection. The Hi-Touch platform extends these core protection functions with advanced measurement, monitoring and power-management capabilities, providing detailed electrical information for sophisticated industrial, infrastructure and critical-power distribution systems.

The E6.2V/f 5000 delivers an ultimate short-circuit breaking capacity of 150 kA at 400/415/440 V AC, 130 kA at 500/525 V AC and 100 kA at 690 V AC. It also provides a rated short-time withstand current of 100 kA for both 1 s and 3 s. Its withdrawable moving-part construction is designed for use with the corresponding Emax 2 fixed part, supporting efficient isolation, inspection and maintenance in critical switchboards.

Key Advantages

  • High-current 5000 A Emax 2 air circuit breaker for demanding low-voltage distribution systems.
  • Four-pole full-size configuration with the neutral rated at 100% of phase current.
  • Ekip Hi-Touch LSI electronic trip unit provides overload, selective short-time and instantaneous short-circuit protection.
  • High 150 kA ultimate breaking capacity at 400/415/440 V AC.
  • 100 kA breaking capacity at 690 V AC for demanding higher-voltage distribution systems.
  • 100 kA short-time withstand capability supports selective coordination in high-fault-level networks.
  • Advanced Hi-Touch measurement and monitoring functionality supports sophisticated power-management applications.
  • Withdrawable moving-part construction supports efficient isolation, inspection and servicing.

Key Features

  • ABB SACE Emax 2 E6.2V/f full-size series.
  • 5000 A rated uninterrupted current.
  • 4-pole configuration.
  • 100% neutral-pole current rating.
  • Ekip Hi-Touch LSI electronic protection release.
  • Long-time overload protection (L).
  • Selective short-time short-circuit protection (S).
  • Instantaneous short-circuit protection (I).
  • Advanced electrical measurement and monitoring functionality.
  • Rated operational voltage: 690 V AC.
  • Rated insulation voltage: 1000 V AC.
  • Rated impulse withstand voltage: 12 kV.
  • 150 kA ultimate breaking capacity at 400/415/440 V AC.
  • 100 kA short-time withstand current for 1 s and 3 s.
  • Withdrawable moving-part design for use with the corresponding fixed part.

Advanced Selective Protection and Power Monitoring

Air circuit breakers such as the ABB Emax 2 E6.2V/f protect major low-voltage distribution circuits against overload and short-circuit conditions. The Ekip Hi-Touch LSI release combines long-time, selective short-time and instantaneous protection, enabling engineers to coordinate protective devices across different levels of the distribution network and minimise unnecessary interruption of healthy circuits.

The combination of a 5000 A continuous-current rating, 150 kA breaking capacity at 400/415/440 V AC, advanced Hi-Touch functionality and a 100 kA short-time withstand rating makes the 1SDA073348R1 particularly suitable for large industrial and infrastructure switchboards. Its withdrawable architecture further supports maintenance strategies by allowing the moving breaker assembly to be isolated from the separately installed fixed part.

Typical Applications

  • Main incoming protection in high-current low-voltage switchboards.
  • Industrial power-distribution systems.
  • Transformer secondary protection and distribution.
  • Generator and power-generation distribution systems.
  • Manufacturing and process-industry switchboards.
  • Commercial and infrastructure electrical distribution.
  • Data centres and continuity-critical power systems.
  • High-current feeders requiring advanced selective LSI protection and electrical monitoring.

Technical Specifications

Series SACE Emax 2 E6.2
ABB order code 1SDA073348R1
EAN 8015644771980
Country of origin Italy
Product type Air circuit breaker moving part
Frame configuration E6.2V/f full size
Performance level V
Rated uninterrupted current (Iu) 5000 A
Number of poles 4
Neutral-pole current 100% of Iu
Current type AC
Trip unit Ekip Hi-Touch LSI
Release type Electronic
Protection functions Long-time, short-time and instantaneous (LSI)
Rated operational voltage (Ue) 690 V AC
Rated insulation voltage (Ui) 1000 V AC
Rated impulse withstand voltage (Uimp) 12 kV
Ultimate breaking capacity (Icu) at 400 V AC 150 kA
Ultimate breaking capacity (Icu) at 415 V AC 150 kA
Ultimate breaking capacity (Icu) at 440 V AC 150 kA
Ultimate breaking capacity (Icu) at 500/525 V AC 130 kA
Ultimate breaking capacity (Icu) at 690 V AC 100 kA
Service breaking capacity (Ics) 100% of Icu
Rated short-time withstand current (Icw), 1 s 100 kA
Rated short-time withstand current (Icw), 3 s 100 kA
Installation Withdrawable
Construction Moving part (WMP)
Fixed part Ordered separately
Power loss 850 W
Mechanical durability 12000 cycles
Electrical durability at ≤440 V AC 3000 cycles
Electrical durability at 500–690 V AC 2000 cycles
Product weight 159 kg
Applicable standard IEC 60947-2

Frequently Asked Questions

What is the ABB 1SDA073348R1?

The ABB 1SDA073348R1 is an Emax 2 E6.2V/f full-size withdrawable air circuit breaker moving part rated at 5000 A, with four poles and an Ekip Hi-Touch LSI electronic protection release.

What protection does the Ekip Hi-Touch LSI trip unit provide?

The Ekip Hi-Touch LSI provides long-time overload (L), selective short-time short-circuit (S) and instantaneous short-circuit (I) protection, together with advanced electrical measurement and monitoring functionality.

What is the breaking capacity of the ABB E6.2V/f 5000?

The E6.2V/f 5000 provides an ultimate short-circuit breaking capacity of 150 kA at 400/415/440 V AC, 130 kA at 500/525 V AC and 100 kA at 690 V AC.

Does the ABB 1SDA073348R1 include earth-fault protection?

No. This model uses an Ekip Hi-Touch LSI release providing long-time, short-time and instantaneous protection. An Ekip Hi-Touch LSIG configuration is available where integrated earth-fault protection is required.

Is the ABB 1SDA073348R1 fixed or withdrawable?

It is a withdrawable moving part (WMP) designed for use with the corresponding ABB SACE Emax 2 fixed part, which is ordered separately and installed in the switchboard.

Trusted Protection for High-Current Power Distribution

ABB SACE Emax 2 air circuit breakers combine high-current switching, advanced electronic protection, electrical monitoring and maintainable withdrawable construction to provide dependable selective protection for demanding low-voltage power-distribution systems.